XO1 Operators Manual
Page 19
Delay Screen
To adjust delay settings:
Use the ‘FREQ’ control for coarse control. (1mS steps)
Use the ‘Q’ control for fine control. (2.6
P
S steps)
Each input and output has an independent delay time control. Input delay (base delay)
is adjustable in 1mS steps. Output delay is adjustable in 2
.
6
P
S steps or in 1mS steps
giving complete control over driver time alignment.
The combination of input (base) delay and output delay can be a maximum of 650mS.
So, for example, setting a base delay of 500mS on input A will only leave 150mS for
any outputs that are sourced from input A. The exception to this rule is for any ‘aux’
outputs (available in 4 and 5 way crossover modes). Choosing the source as a mono
sum (Inputs A + B) will allow 650mS of output delay, regardless of the input delay
settings.
For further details on this topic, see the section entitled
“Time Alignment” on page 32.