6. Press CH DOWN button on the VCR until the CTL
waveform has shifted from its original position (not
the position achieved in step 5, but the position of
CTL waveform in step 4) by approximately
-2msec. Make sure that the envelope is simply at-
tenuated (shrinks in height) once CTL waveform
passes its original position and is further brought
in the minus direction.
7. Set the Tracking Control Circuit to the center posi-
tion by pressing the CH UP button and then the
PLAY button on the VCR.
1-C. Checking/Adjustment of Envelope
Waveform
Purpose:
To achieve a satisfactory picture and precise tracking.
Symptom of Misalignment:
If the envelope output is poor, noise will appear in the
picture. The tracking will then lose precision and the
playback picture will be distorted by any slight variation
of the Tracking Control Circuit.
1. Connect the oscilloscope to TP301 (C-PB) on the
Main CBA. Use TP502 (RF-SW) as a trigger.
2. Play back the Gray Scale on the Alignment Tape
(FL6N8). Set the Tracking Control Circuit to the
center position by pressing the CH UP and then
the PLAY button on the VCR. Adjust the height of
Guide Rollers [2] and [3] (Fig. M3, Page 2-3-3)
watching the oscilloscope display so that the enve-
lope becomes as flat as possible. To do this adjust-
ment, turn the top of the Guide Roller with the
Guide Roller Adj. Screwdriver.
3. If the envelope is as shown in Fig. M7, adjust the
height of Guide Roller [2] (Refer to Fig. M3) so
that the waveform looks like the one shown in Fig.
M9.
4. If the envelope is as shown in Fig. M8, adjust the
height of Guide Roller [3] (Refer to Fig. M3) so
that the waveform looks like the one shown in Fig.
M9.
5. When Guide Rollers [2] and [3] (Refer to Fig.M3)
are aligned properly, there is no envelope drop
either at the beginning or end of track as shown in
Fig. M9.
Note: Upon completion of the adjustment of Guide
Rollers [2] and [3] (Refer to Fig. M3), check the X Value
by pushing the CH UP or DOWN buttons alternately, to
check the symmetry of the envelope. Check the number
of pushes to ensure center position. The number of
pushes UP to achieve 1/2 level of envelope should
match the number of pushes DOWN from center. If
required, redo the "X Value Alignment."
1-D. Azimuth Alignment of Audio/Control/
Erase Head
Purpose:
To correct the Azimuth alignment so that the Audio/Con-
trol/Erase Head meets tape tracks properly.
Symptom of Misalignment:
If the position of the Audio/Control/Erase Head is not
properly aligned, the Audio S/N Ratio or Frequency
Response will be poor.
1. Connect the oscilloscope to the audio output jack
on the rear side of the deck.
2. Play back the alignment tape (FL6N8) and confirm
that the audio signal output level is 8 kHz.
3. Adjust Azimuth Adj. Screw so that the output level
on the AC Voltmeter or the waveform on the oscil-
loscope is at maximum. (Fig. M6)
Dropping envelope level at the beginning of track.
Fig. M7
Dropping envelope level at the end of track.
Fig. M8
Envelope is adjusted properly. (No envelope drop)
Fig. M9
2-3-4
H8740MA
Summary of Contents for 23C-250
Page 22: ...1 8 3 1 8 4 1 8 5 H8624SCM1 Main 1 4 Schematic Diagram...
Page 23: ...1 8 6 1 8 7 1 8 8 H8624SCM2 Main 2 4 Schematic Diagram...
Page 24: ...1 8 9 1 8 10 1 8 11 H8624SCM3 Main 3 4 Schematic Diagram...
Page 25: ...1 8 12 1 8 13 1 8 14 H8624SCM4 Main 4 4 Schematic Diagram Function Schematic Diagram H8743SCF...
Page 26: ...1 8 15 1 8 16 Jack Schematic Diagram H8622SCJ...
Page 27: ...1 8 17 1 8 18 SECAM Schematic Diagram H8624SCS...
Page 30: ...1 8 26 1 8 25 BH8700F01031 Function CBA Top View Function CBA Bottom View...
Page 31: ...1 8 28 1 8 27 BH8700F01021 Jack CBA Top View Jack CBA Bottom View...
Page 32: ...1 8 30 1 8 29 SECAM CBA Top View SECAM CBA Bottom View BH8700F01011 C...
Page 58: ...EXPLODED VIEWS Front Panel A1X 3 1 1 H8743FEX...
Page 60: ...Packing Some Ref Numbers are not in sequence S2 S2 X4 S1 X1 X2 X20 X3 Unit S3 3 1 3 H8740PEX...
Page 78: ...23C 250 23C 250A H8743FP Printed in Japan 2001 04 20 HO...