Preview Adjustment
1.
Mark a new, properly adjusted square
2.
Without moving the part you just engraved, press “Preview Square”
3.
Use the adjustment buttons so that the red dot trace perfectly overlaps the marked square.
4.
Select “Save Preview Adjustment.
Camera Shutter Replacement
Fig. 28
Fig. 29
1.
Power off and unplug your unit.
Wait at least 1 hour for capacitors to discharge.
2.
The Shutter has 4 M4 screws. The first two hold the motor in place and the others attach the shutter to
the motor. (See above).
43
For more help, please check our video on focusing your laser and camera
calibration @
https://www.youtube.com/watch?v=SZFqi_WLHBI
.