61
VECTOR CURRENT %
Total power is determined by a combination of delivered current and voltage to the laser tube. The
current is directly regulated while voltage is controlled by PWM (Pulse Width Modulation). PWM is
a technique whereby an average voltage is delivered in a series of pulses per unit time. In Vector
mode you can control both the PWM frequency (power) as well as the delivered current (Vector
Current %). In Raster mode, the output is pulsed based on the speed and pixel pattern, so only
current control is available (Raster Power %).
VECTOR IMPORT OPTIONS
IGNORE RASTER
Select this option to speed up processing of large vector files on computers with limited memory.
Raster data is memory intensive for large drawings at the highest resolutions and is unneeded if
only vector cutting is required.
IGNORE ALL VECTOR
The existing documents in the Vector Cut is not replaced when loading new documents.
IGNORE THIN VECTOR
Disables vectorable content from Raster Tab and nonvectorable content from Vector Tab.
Vectorable is defined as having linewidth set to hairline. All other objects, including images, are
nonvectorable. This option is useful when importing projects with the intention of “Raster then
Vector” (Combined Mode).
TOLERANCE
Override the Config File Import Tolerance Setting. This is used to determine the amount of points
generated for objects on Vector Import.
AUTOMATIC MODE
Start jobs as soon as they are printed using default settings.
Technical Support is available from 8:00 am (PST) to 5:00 pm (PST) Monday through Friday at
.
Summary of Contents for HL40-5g Hobby Advanced