background image

ENVIRONMENTAL INFORMATION 

Packaging:

The materials used in the packaging of Full Gauge products are 100% recyclable. Try to 
perform disposal through specialized recyclers.

Product:

The  components  used  in  Full  Gauge  controllers  can  be  recycled  and  reused  if 
disassembled by specialized companies.

Disposal:

Do not incinerate or dispose the controllers that have reached the end of their service as 
household  garbage.  Observe  the  laws  in  your  area  regarding  disposal  of  electronic 
waste. If in doubt, please contact Full Gauge Controls.

Ecase

It is recommended for the Evolution line, keeps water from entering the back part of the instrument. It 
also protects the product when the installation site is washed.

Extension Frame

The  Full  Gauge  Controls  extension  frame  allows  the  installation  of  Evolution  /  Ri  line  with  measures 
76x34x77 mm (dimensions of the clipping for fixing in the extension frame is 71x29mm) in varied situations, 
since it eliminates precision cut to embed the instrument. Allows customization via a sticker with the brand 
and the company contact, and accompany two 10A (250 Vac) switches that can trigger internal light, air 
curtain, on / off system or fan.

W

ARRANTY

 - FULL

 GAUGE CONTROLS

Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) year 

warranty, as of the date of the consigned sale, as stated on the invoice. They are guaranteed 
against manufacturing defects that make them unsuitable or inadequate for their intended 
use.

EXCEPTIONS TO WARRANTY

The Warranty does not cover expenses incurred for freight and/or insurance when sending 

products  with  signs  of  defect  or  faulty  functioning  to  an  authorized  provider  of  technical 
support services. The following events are not covered either: natural wear and tear of parts; 
external damage caused by falls or inadequate packaging of products.

LOSS OF WARRANTY

Products will automatically lose its warranty in the following cases:
- The instructions for assembly and use found in the technical description and installation 

procedures in Standard IEC60364 are not obeyed;

-  The  product  is  submitted  to  conditions  beyond  the  limits  specified  in  its  technical 

description;

- The product is violated or repaired by any person not a member of the technical team of 

Full Gauge Controls;

- Damage has been caused by a fall, blow and/or impact, infiltration of water, overload 

and/or atmospheric discharge.

USE OF WARRANTY

To make use of the warranty, customers must send the properly packaged product to Full 

Gauge Controls together with the invoice or receipt for the corresponding purchase. As much 
information as possible in relation to the issue detected must be sent to facilitate analysis, 
testing and execution of the service.

These  procedures  and  any  maintenance  of  the  product  may  only  be  provided  by  Full 

Gauge Controls Technical Support services in the company's headquarters at Rua Júlio de 
Castilhos, 250 - CEP 92120-030 - Canoas - Rio Grande do Sul – Brasil

Copyright 2016

All rights reserved.

Rev. 03

[Err1]

[Err2]

[Err3]

[ALrE] 

[eCO,]  

[Opn,]  

[AOPn]  

[Athi]

[Atlo]  

[AC1,]  

[AC2,]  

[ALrC]  

[OFF,]   

[,,,,.]

[eCAL]

[pppp]

7. SIGNALS

Ambient sensor disconnected or out of range.

Evaporator sensor disconnected or out of range.

Sensor 3 disconnected or out of range.

External alarm (digital input).

Operating with economic setpoint.

Open door indication.

Open door alarm indication.

High ambient temperature alarm (sensor1).

Low ambient temperature alarm (sensor1).

High temperature in condenser alarm (level 1).

High temperature in condenser alarm (level 2).

Compressor reached the maximum time on without reaching the SP.

Control routines off.

It indicates that the temperature for end of defrost has not been reached.

Please contact Full Gauge Controls.

Reconfigure the values of the functions.

[,,,2]

Digital input: Perform defrost (N.O. push-button)

[,,,3]

Digital input: Perform fast freezing (N.O. push-button)

[,,,4]

Digital input: External alarm (N.O.)

[,,,5]

Digital input: Door contact (N.O.)

[,,,6]

Digital input: Activate economic setpoint (N.C. push-button) 

[,,,7]

Digital input: Perform defrost (N.C. push-button)

[,,,8]

Digital input: Perform fast freezing (N.C. push-button)

[,,,9]

Digital input: External alarm (N.C.)

[,,10]

Digital input: Door contact (N.C.)

[,,11]

Sensor S3: Temperature differential for economic setpoint (S3-S1)

[,,12]

Sensor S3: Condenser temperature control 

[,,13]

Sensor S3: Temperature control of second evaporator 

F53 - Function of digital input 2:

[Off,]

Not in use

[,,,1]

Digital input: Activate economic setpoint (N.O. push-button) 

[,,,2]

Digital input: Perform defrost (N.O. push-button)

[,,,3]

Digital input: Perform fast freezing (N.O. push-button)

[,,,4]

Digital input: External alarm (N.O.)

[,,,5]

Digital input: Door contact (N.O.)

[,,,6]

Digital input: Activate economic setpoint (N.C. push-button) 

[,,,7]

Digital input: Perform defrost (N.C. push-button)

[,,,8]

Digital input: Perform fast freezing (N.C. push-button)

[,,,9]

Digital input: External alarm (N.C.)

[,,10]

Digital input: Door contact (N.C.)

F54 - Evaporator S2 temperature indication offset:

This function allows compensating for eventual deviations in the evaporator temperature reading (S2), 
resulting from the change of sensor or modification of the cable length. Sensor S2 can be shut down by 
setting this function at minimum until the message 

[,OFF]

 appears. In this condition, all functions 

dependent on the reading of sensor S2 cease to operate.

F55 - Sensor S3 temperature indication offset:

This function allows compensating for eventual deviations in the reading of sensor S3 temperature, 
resulting from the change of sensor or modification of the cable length. Sensor S3 can be shut down by 
setting the function of digital input 1 / Sensor S3 (F52) with the 

[,OFF]

(0) value, or making it operate 

as a digital input.

F56 - Control functions shutdown:

(see section 6.3.8).

Authorizes switching off the control functions 

[no,,]

Disables the control functions shutdown.

[,,,1]

Enables activation/deactivation of the control functions only if the functions are unlocked.

[,,,2]

Enables activation/deactivation of the control functions even if the functions are locked.

[,,,3]

Enables activation/deactivation of the control functions only if the functions are unlocked.*

[,,,4]

Enables activation/deactivation of the control functions even if the functions are locked.*

* When F56 is configured as 3 or 4 and the control functions shutdown is activated, the controller will 
turn off the display, keeping only the indication       light on.
If any key is touched the display turns on by 5 seconds, turning off again until a new key is touched.

F57 - Function lock mode:

It allows and configures the function lock.

[,,,0]

Do not allow the function lock.

[,,,1]

It allows a partial lock where the control functions will be locked but the adjustment of the 

setpoint, date views, and maximum and minimum record views are allowed.

[,,,2]

It allows the full lock.

F58 - Time for functions lock:

Allows lockdown of control functions (see item 6.3.7).

[,,15]

 - 

[,,60]

 - Defines the time in seconds for the controller to activate.

 

 

8. OPTIONAL ITEMS - Sold Separately

EasyProg 

- version 2 or higher

It is an accessory that has as its main function to store the parameters of the controllers. At any time, you 
can load new parameters of a controller and unload them on a production line (of the same controller), 
for example. It has three types of connections to load or unload the parameters:

- Serial RS-485:

 It connects via RS-485 network to the controller (only 

for controllers that have RS-485). 

- USB:

 it can be connected to the computer via the USB port, using 

Sitrad's Recipe Editor.

-  Serial  TTL: 

The  controller  can  be  connected  directly  to 

EasyProg 

by the TTL Serial connection.

EASYPROG