-11-
In st al la ti on an d Wi ri ng
DZB100 Series
SG+
SG-
MCM
DFM
8888
DCM
R
S
T
EV
U
V
W
E
M0
1
M0
2
ACM
FM
MI
1
MI
2
MI
3
REV
FWD
RST
TRG
DCM
10V
VI
CI
ACM
M
1
3
2
7.5KW 132KW
V
MCU
VCC
WR
Panel Resistor
VI
CI
S
2
Frequency setting
0~10V
A
C
B
(EF)
MI
4
P1
DC-
Braking unit (option)
P2
DCLinkReactor(option)
Braking resistior
I
I
I
Frequency setting
4~20mA
S
1
Power source
3 phase
200-240V or
380-480V
50/60Hz
R
S
T
Use a disconnect
and fuse
Frequency setting
0~10VDC
Vr:3k~5k
RS-485 Serial interface
Multi-function PHC output
48V 50mAbelow
Analog frequency/
current meter
DC0-10V
Multi-function indication
output contact
Multi-function input 1
Multi-function input 2
Multi-function input 3
REV/STOP(REV/STOP)
FWD/STOP(RUN/STOP)
Counter trigger input
Digital signal common
Grounding
shows main circuit
shows control circuit
DC 20V ~ 24V ( 50mA Max. )
Digital frequency meter
Reset
Multi-function input 4
(
External fault)
Signal-
AC 250V 2Abelow
DC 30V 2Abelow
Current input
4~20mA
+
-