EN
11
Adapting to different types of gas
If the appliance is configured for a different type of gas than
that available, you have to replace the injectors with ones
corresponding to the type of gas to be used (see tables on
the preceding pages). The replacement will be made using
an adequate 7 mm key after having lowered the burners as
in the following images. After replacing the injector, regulate
the air to 1mm for natural gas and to the maximum if LPG.
To adjust the minimum, after lighting the burner, remove the
knob and the gasket below and rotate the screw of the tap
(B - see page 12), which should be totally closed for
LPG and opened about 3/4 turn for natural gas, keeping
in mind that a flame lower than 3 mm may not even be
“perceived” by the thermocouple of the tap. After regulating
the minimums, replace the gaskets and knobs.
1 - Unscrew the fixing screws of the burner.
BACK
FRONT
2 - Lower the burner and replace the injector.
FRONT
BACK
Summary of Contents for FOBQ 1000 G MBK
Page 2: ......
Page 15: ...IT 13 Dettaglio di allacciamento del gas 52 47 488 Con nota collegamento gas naturale GN ...
Page 24: ...IT 22 BP 5 kg BUTAGAZ 6 kg CALOR 5 kg PRIMAGAZ 5 2 kg ...
Page 35: ...IT 33 ...
Page 49: ...EN 13 Detail of the gas connection 52 47 488 With note natural gas connection NG ...
Page 58: ...EN 22 BP 5 kg BUTAGAZ 6 kg CALOR 5 kg PRIMAGAZ 5 2 kg ...
Page 69: ...EN 33 ...
Page 83: ...DE 13 Detail des Gasanschlusses 52 47 488 Mit Hinweis Erdgasanschluss GN ...
Page 89: ...DE 19 505 1025 Wichtige Lüftungsöffnung Gitter oder Lüftungsöffnungen 700 135 240 660 25 105 ...
Page 92: ...DE 22 BP 5 kg BUTAGAZ 6 kg CALOR 5 kg PRIMAGAZ 5 2 kg ...
Page 103: ...DE 33 ...
Page 117: ...ES 13 Detalle de conexión del gas 52 47 488 Con nota conexión gas natural GN ...
Page 126: ...ES 22 BP 5 kg BUTAGAZ 6 kg CALOR 5 kg PRIMAGAZ 5 2 kg ...
Page 137: ...ES 33 ...
Page 139: ......
Page 140: ...DOC COD 1 00A 34 1 05 19 ...