Features
y
The display unit can display maximum of 14 waveforms. Also, various displays such as enlarged
numeric data, trend, or ventilator can be selected according to monitoring conditions.
y
The operation can be performed with the touch panel. Also, frequently used keys can be
assigned on the screen as user keys.
y
The alarm indicator notifies the alarm with different flashing patterns corresponding to the alarm
level so that the users can easily identify the alarm level of the generating alarm.
y
Using the CF-820 IR Remote Control Unit allows to remotely control the patient monitor.
y
Using the multiparameter amplifier, the HS-8000 series Super Unit is capable of monitoring
parameters in combination of BP (max. 6 ch.), temperature (max. 6ch.), and CO (max. 1ch.).
y
In addition to ECG, respiration, SpO
2
(pulse wave), BP, NIBP, temperature and CO, the
measurement of CO
2
concentration is also available as optional function.
y
For the SpO
2
measurement, two model types with different built-in SpO
2
modules are available,
which are Covidien/NellcorTM and Masimo.
y
SpCO, SpMet, SpHb, and PVI are optional parameters which can be measured on the HS-8312M
with the Masimo built-in SpO
2
module.
y
By connecting the ventilator to STATUS II port on the Base Unit, airway flow, airway pressure
waveform, minute ventilation, airway resistance, etc. can be monitored. Also, ventilator alarm can
be notified to the central monitor via telemetry system and wired network. The following
ventilators can be connected.
・
SV-900C/900D/900E
・
SV-300/300A
・
Servo-i/Servo-s
・
PURITAN-BENNETT Ventilator 740/780, 840
・
Evita 4/Evita XL/Evita 2 dura
y
Wired network (DS-LANII/DS-LANIII) construction is possible.
y
DS-LANII is a network based on 10BASE-T with transmission speed of 10Mbps and maximum
transmission distance of 100m. DS-LANIII is a network based on 100BASE-TX with transmission
speed of 100Mbps and maximum transmission distance of 100m.
y
Wireless network construction is possible using the optional HLX-801 Telemetry Transmitter
Module.
y
By using the optional recorder unit (HR-800), the measurement data can be output on the
recorder.
y
By connecting the Gas Unit I/F (HPD-800/HPD-810) or CO
2
Gas Unit (HCP-800/HCP-810) to the
AUX connector on the HS-8000 series Super Unit, CO
2
concentration can be measured.
y
By connecting the oximeter to the STATUS II port or COM1 port on the Base Unit, SvO
2
(mixed
venous oxygen saturation), CO (cardiac output), etc. can be monitored. The following
oximeter/CCO measurement devices can be connected.
・
Vigilance
・
Vigilance CEDV
・
Vigilance II
・
Vigileo by Edwards Lifesciences
y
By connecting the A-2000 BIS Monitor (ASPECT MEDICAL SYSTEMS) /BIS Vista A-3000
(Covidien) to the STATUS II port or COM1 port on the Base Unit, the patient's wakeful state can
be monitored.
y
By connecting the aepEX PLUS AEP Monitor (Medical Device Management) to the STATUS II
port or COM1 port on the Base Unit, AEP index can be monitored.
y
By connecting the INVOS 5100C Non-Invasive Cerebral Oximeter (Covidien) to the STATUS II
port or COM1 port on the Base Unit, regional cerebral oxygen saturation data can be monitored.
1-3