Heat Pump, Split System, Single Service, 3 phase
6
Maintenance
Document
1394-1
1 Technical
Characteristics
1.1 Specifications
Heating system operating limits
WATERSTAGE
112
WATERSTAGE
140
WATERSTAGE
160
Exterior temp mini/maxi
°C
-20/+35
Initial max heating water temperature
- Floor heating system
°C
45
- Low temperature radiator
°C
60
Flow min heating water temperature
°C
8
1.2 Performance
Data
1.2.1 Rated Performance
HEAT PUMP
WATERSTAGE
112
WATERSTAGE
140
WATERSTAGE
160
P
out
(kW)
11,2
14,00
16,00
P
in
(kW)
2,51
3,22
3,72
+ 7°C/ + 35°C
-
HCF COP
4,46
4,35
4,30
P
out
(kW)
11,2
14,00
15,00
P
in
(kW)
3,92
5,15
5,55
- 7°C/ + 35°C
-
HCF
COP
2,86
2,72
2,70
P
out
(kW)
10,5
13,1
15,1
P
in
(kW)
2,9
3,7
4,42
+ 7°C/ + 45°C
-
LT Radiators
COP
3,62
3,54
3,42
P
out
(kW)
10,5
13,1
14,5
P
in
(kW)
4,16
5,39
6,38
- 7°C/ + 45°C
-
LT Radiators
COP
2,52
2,43
2,27
1.2.2 Maximum Stated Performance
HEAT PUMP
WATERSTAGE
112
WATERSTAGE
140
WATERSTAGE
160
P
out
(kW)
20,26 21,91 23,39
P
in
(kW)
5,06
5,75
6,5
+ 7°C/ + 35°C
-
HCF COP
4,00
3,81
3,60
P
out
(kW)
17,09
18,67
20,20
P
in
(kW)
5,04
5,67
6,43
+ 7°C/ + 45°C
-
LT Radiators
COP
3,39
3,29
3,14