44
I
Operation HC2 (command HC2)
Commonly with HC1,
Independent
Commonly with
HC1
Commonly with HC1 or Independent : This function enables you to choose whether you wish the room thermostat (as
an option) to act on both zones or just a single zone.
46
I
Operation HCP (domestic hot water pump command, output QX2)
Commonly with
HC1
Commonly with HC1 or Independent (if independent, see timer program 3 / HCP)
70
S
Software version (Display)
Heating time programme, circuit 1
500
U
Pre-selection (Day / Week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday…
Mon-Sun
501
U
1
st
phase On (start)
00:00... --:--
10 min
6:00
502
U
1
st
phase Off (end)
00:00... --:--
10 min
22:00
503
U
2
nd
phase On (start)
00:00... --:--
10 min
--:--
504
U
2
nd
phase Off (end)
00:00... --:--
10 min
--:--
505
U
3
rd
phase On (start)
00:00... --:--
10 min
--:--
506
U
3
rd
phase Off (end)
00:00... --:--
10 min
--:--
516
U
Default values, Circuit 1
No, Yes
No
Yes + OK : The Default values memorised in the regulator replace and cancel the customised heating programmes.
Your customised settings are therefore lost.
Heating time programme, circuit 2
Only with the 2nd circuit kit option
520
U
Pre-selection (Day / Week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday…
Mon-Sun
521
U
1
st
phase On (start)
00:00... --:--
10 min
6:00
522
U
1
st
phase Off (end)
00:00... --:--
10 min
22:00
523
U
2
nd
phase On (start)
00:00... --:--
10 min
--:--
524
U
2
nd
phase Off (end)
00:00... --:--
10 min
--:--
525
U
3
rd
phase On (start)
00:00... --:--
10 min
--:--
526
U
3
rd
phase Off (end)
00:00... --:--
10 min
--:--
536
U
Default values, Circuit 2
No, Yes
No
Yes + OK : The Default values memorised in the regulator replace and cancel the customised heating programmes.
Your customised settings are therefore lost.
Programme 3/ HCP
Domestic hot water pump program, lines 540 to 556.
Time programme 4 / DHW
If the installation is fitted with a DHW tank. (Only with the DHW kit option).
560
U
Pre-selection (Day / Week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday…
Mon-Sun
561
U
1
st
phase On (start)
00:00... --:--
10 min
00:00
562
U
1
st
phase Off (end)
00:00... --:--
10 min
05:00
563
U
2
nd
phase On (start)
00:00... --:--
10 min
--:--
564
U
2
nd
phase Off (end)
00:00... --:--
10 min
--:--
565
U
3
rd
phase On (start)
00:00... --:--
10 min
--:--
566
U
3
rd
phase Off (end)
00:00... --:--
10 min
--:--
576
U
Default values
No, Yes
No
Line
Function
Setting range
or display
Setting
increment
Basic
setting
Installation and operating manual "1364 - EN"
- 33 -
Heat pump split single service 3 phase