En-13
Notice
When setting the operating mode for each indoor unit,
setting combinations are restricted. Possible setting
combinations are as follows:
Conditions
Possible setting
combination
Indoor units other than selected one
are under the Cool operation.
Cool, Dry
Fan, Auto
Indoor units other than selected one
are under the Dry operation.
Cool, Dry
Fan, Auto
Indoor units other than selected one
are under the Heat operation (10 °C
heat operation).
Heat, Auto
When the Cool operation mode is
fi
xed *
Cool, Dry
Fan, Auto
When the Heat operation mode is
fi
xed *
Heat, Auto
* Only where the signal is transmitted from the outdoor
unit through the external input. For details, contact
your authorized service personnel.
6-3-3. Room temperature setting
1
Select “Set temp.” with the [Cursor button (Left/Right)]
and set the room temperature with the [Cursor button (Up/
Down)].
Mo 10:00AM
Operation
Room 1
Fan/10 °C Heat/Economy
Cancel:
OK:
Mode
Cool
Set temp.
°C
26
On-Off
On
Notice
• Possible temperature setting ranges in the operation
mode are as follows:
Cool, Dry, Auto ............... 18 to 30 °C (64 to 88 °F)
Heat ............................... 16 to 30 °C (60 to 88 °F)
• When operation mode is set to “Fan”, Room tem-
perature cannot be set. (“Set temp.” cannot be
selected.)
• If the operation mode is set to “Auto” and the room
temperature or setting temperature is significantly
different in each room, each indoor unit may have an
impossible setting combination. In this case, set to
possible settings operation mode except “Auto”.
11
2
Other operation setting items can be set continuously.
To complete the setting, press the [Enter button], then it
returns to the “Operation (unit select)” screen.
6-3-4. Fan speed setting
1
Select “Fan” with the [Cursor button (Left/Right)], and set
the fan speed with the [Cursor button (Up/Down)].
Fan speed marks
Mo 10:00AM
Operation
Room 1
On-Off/Mode/Set temp.
Cancel:
OK:
10 °C Heat
Off
Off
Economy
Fan
High
Auto
Quiet
Low
Med
High
Notice
When the operation mode is set to “Dry”, Fan speed
switches to “Auto”. (Fan speed cannot be selected).
2
Other operation setting items can be set continuously.
To complete the setting, press the [Enter button], then it
returns to the “Operation (unit select)” screen.
6-3-5. 10 °C heat setting
1
Select “10 °C Heat” with the [Cursor button (Left/Right)]
and set “On” with the [Cursor button (Up/Down)], 10 °C
heat operation starts.
Mo 10:00AM
Operation
Room 1
On-Off/Mode/Set temp.
Cancel:
OK:
10 °C Heat
Economy
Fan
High
On
9380221012-03_OM_en.indd 13
9380221012-03_OM_en.indd 13
30/11/2553 15:25:02