background image

En-4

 CAUTION

•  To prevent malfunction or damage of the remote 

controller:

 

- Place remote controller at where will not be 

exposed to direct sunlight or excessive heat.

 

- Remove batteries if the product is not going to be 

used for an extended period.

•  Obstacles such as a curtain or wall between the 

remote controller and the indoor unit may affect the 

appropriate signal transmission.

•  Do not apply strong shocks to the remote controller.
•  Do not pour water on the remote controller.

For Powerful operation  ................. Refer to page 7.

Activates or deactivates the Powerful 

operation.

For Air

fl

 ow settings  ....................... Refer to page 5.

Controls the fan speed.

 

Sets the automatic Swing operation.

 

Controls the up and down air

fl

 ow direction.

After replacing batteries

 Press this button as shown in the following 

fi

 gure. 

Use a tip of a ballpoint pen or other small object.

RESET

For Timer operations ..................... Refer to page 5.

Activates or deactivates the Weekly timer.

Activates or deactivates the On timer, Off 

timer, or Program timer.

Activates or deactivates the Sleep timer.

Starts the timer setting.

Sends the timer or clock setting to the indoor 
unit.
Forwards the timer or clock setting to the 
next step.
Returns the timer or clock setting to the 
previous step.

Adjusts the value of the timer or clock 
settings.

Starts the clock setting.

Signal transmitter

Aim at the signal receiver of the indoor unit properly. 

• Operating range is approximately 7 m.
• [   ] will appear when the signal is transmitted.

• The indoor unit will emit a beep when it receive the signal 

properly. If there is no beep, press the button again.

00_9378532090_OM.indb   4

00_9378532090_OM.indb   4

2020/8/31   16:43:48

2020/8/31   16:43:48

Summary of Contents for Suelo AGY25-KV

Page 1: ... EMPLOI CLIMATISEUR Type àu sol Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo suelo Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo da pavimento Prima di u...

Page 2: ...ng the power plug Then consult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning...

Page 3: ...places or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any other electrical products or household belongings under this product Dripping condensation from this product might get them wet and may cause damage or malfunction of your propert...

Page 4: ...each remote controller The setting must be done while the setting screen is displayed for each function The button is controllable only when the air conditioner is operating For Energy saving operation Refer to page 7 Activates or deactivates the Economy operation Battery loading and remote controller preparation R03 LR03 AAA x 2 5 7 6 4 8 1 2 3 1 3 Put batteries as shown in the figure above 4 Pre...

Page 5: ...d down airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the timer or clock settin...

Page 6: ...y setting C 3 Press to switch the temperature unit C F 4 Press to finish the setting If you do not press the button for 30 seconds the displayed temperature unit will be set 5 2 Airflow direction setting For details of the airflow ranges refer to Airflow direction range Up and down airflow direction setting Press to adjust the Up and down airflow direction Left and right airflow direction setting ...

Page 7: ...be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer 6 TIMER OPERATIONS NOTES When indicator on the indoor unit blinks set the clock and timer again This blinking shows that the internal clock go wrong due to an interru...

Page 8: ...wly NOTES In multi connection this function cannot be used Press to activate deactivate the Outdoor Unit Low Noise operation While the Outdoor Unit Low Noise operation is activated on the remote controller is displayed The setting is preserved even if the air conditioner is turned off Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Prog...

Page 9: ...personnel initially set to A If you do not press any buttons for 30 seconds after the custom code is displayed the display returns to the clock display In this case repeat the setting from step 2 Depending on the remote controller the custom code may return to A when replacing the batteries In this case reset the custom code as necessary If you do not know the air conditioner custom code try each ...

Page 10: ...t beyond the frame 10 Replace the air filter and close the intake grille Refer to steps 4 5 of Cleaning air filter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter 2 Remove the air filter Lift up the air filter and pull o...

Page 11: ...for the outdoor unit refer to the outdoor unit installation manual 12 OPTIONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard indicator on the indoor unit will blink Res...

Page 12: ...g set In this case the indoor unit fan may stop temporarily while the Cooling operation To cancel the Fan control for energy saving refer to page 7 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the set temperature In this case the ou...

Page 13: ...of Auto restart Reset the clock and timer settings 10 Test run operation for authorized personnel only Press to quit the test run 3 8 times 10 times Fast Refrigerant leakage suspicion Blowing operation is performed to prevent the refrigerant from accumulating Open the windows to ventilate the room and contact an authorized service personnel Press the button to stop the buzzer sound 5 times 4 times...

Reviews: