Fujitsu Suelo AGY25-KV Operation Manual Download Page 2

En-1

1. SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section 

carefully before you use this product, and be sure to comply 

with the following safety precautions.
Incorrect operation due to failure to follow the instructions may 

cause harm or damage, the seriousness of which is classi

fi

 ed 

as follows:

 WARNING

This mark warns of death or serious injury.

 CAUTION

This mark warns of injury or damage to property.

This mark denotes an action that is PROHIBITED.

This mark denotes an action that is COMPULSORY.

Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this product uses a 

fl

 ammable refrigerant. If the refrigerant is leaked and 

exposed to an external ignition source, there is a risk 

of 

fi

 re.

CAUTION

This symbol shows that the operation manual should 

be read carefully.

CAUTION

This symbol shows that a service personnel should 

be handling this equipment with reference to the 

installation manual.

CAUTION

This symbol shows that information is available such 

as the operation manual or installation manual.

 WARNING

•  The appliance shall be installed, operated and stored 

in a room with a 

fl

 oor area larger than X m².

Amount of refrigerant charge

M (kg)

Minimum room area

X (m

2

)

 1.22 

-

1.22 < M 

 1.23

12.99

1.23 < M 

 1.50 

19.31

1.50 < M 

 1.75 

26.28

1.75 < M 

 2.0 

34.33

2.0 < M 

 2.5 

53.63

2.5 < M 

 3.0 

77.23

3.0 < M 

 3.5 

105.12

3.5 < M 

 4.0 

137.29

(IEC 60335-2-40)

•  This product contains no user-serviceable parts. 

Always consult authorized service personnel for 

repairing, installation, and relocation of this product.

Improper installation or handling will cause leakage, 

electric shock, or 

fi

 re.

•  In the event of a malfunction such as burning smell, 

immediately stop operation of the air conditioner, and 

disconnect all the power supply by turning off the 

electrical breaker or disconnecting the power plug.

Then consult authorized service personnel.

•  Take care not to damage the power supply cable.

If it is damaged, it should be replaced only by 

authorized service personnel in order to avoid a 

hazard.

•  In the event of refrigerant leakage, be sure to keep 

away from 

fi

 re or any 

fl

 ammables, and consult 

authorized service personnel.

•  In the event of a thunder storm or any prior sign 

of a lightning strike, turn off the air conditioner via 

the remote controller, and refrain from touching the 

product or the power source to prevent any electrical 

hazards.

•  This product shall be stored in a room without 

continuously operating ignition sources (for example: 

open 

fl

 ames, an operating gas appliance or an 

operating electric heater).

•  This product shall be stored in a well-ventilated area.
•  Be aware that refrigerants may not contain an odour.
•  This product shall be stored so as to prevent 

mechanical damage from occurring.

•  Disposing of the product shall be done properly, in 

compliance with national or regional regulations.

•  During transportation or relocation of the indoor unit, 

pipes shall be covered with the wall hook bracket for 

protection.

Do not move this product by holding the indoor unit pipes.

(The stress applied to the pipe joints may cause the 

fl

 ammable gas to leak during operation).

Contents

1. SAFETY PRECAUTIONS 

.......................................... 1

2. PREPARATION 

......................................................... 2

3.  NAME OF PARTS ..................................................... 3

3.1. Indoor 

unit 

........................................................ 3

3.2. Remote 

controller 

............................................. 3

4. BASIC OPERATIONS 

............................................... 5

5. AIRFLOW SETTINGS 

............................................... 5

5.1.  Fan speed setting ............................................. 5
5.2. Air

fl

 ow direction setting .................................... 5

6. TIMER OPERATIONS 

............................................... 6

6.1. Weekly 

timer 

..................................................... 6

6.2.  On timer or Off timer ......................................... 7
6.3. Program 

timer 

................................................... 7

6.4.  Sleep timer  ...................................................... 7

7.  ENERGY SAVING OPERATION ............................... 7

7.1. Economy 

operation 

.......................................... 7

8. OTHER OPERATIONS 

............................................. 7

8.1. Powerful 

operation 

........................................... 7

8.2.  Outdoor Unit Low Noise operation ................... 7
8.3.  10 °C Heat operation ........................................ 8

9.  SETTINGS ON INSTALLATION ................................ 8

9.1.  Remote controller custom code setting ............ 8

10. CLEANING AND CARE ............................................. 8
11. GENERAL INFORMATION ..................................... 10
12. OPTIONAL PARTS ................................................. 10

12.1. Wired remote controller .................................. 10
12.2. Multi-split type air conditioner ......................... 10

13. TROUBLESHOOTING ............................................ 11

[Original Instructions]

00_9378532090_OM.indb   1

00_9378532090_OM.indb   1

2020/8/31   16:43:48

2020/8/31   16:43:48

Summary of Contents for Suelo AGY25-KV

Page 1: ... EMPLOI CLIMATISEUR Type àu sol Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo suelo Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo da pavimento Prima di u...

Page 2: ...ng the power plug Then consult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning...

Page 3: ...places or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any other electrical products or household belongings under this product Dripping condensation from this product might get them wet and may cause damage or malfunction of your propert...

Page 4: ...each remote controller The setting must be done while the setting screen is displayed for each function The button is controllable only when the air conditioner is operating For Energy saving operation Refer to page 7 Activates or deactivates the Economy operation Battery loading and remote controller preparation R03 LR03 AAA x 2 5 7 6 4 8 1 2 3 1 3 Put batteries as shown in the figure above 4 Pre...

Page 5: ...d down airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the timer or clock settin...

Page 6: ...y setting C 3 Press to switch the temperature unit C F 4 Press to finish the setting If you do not press the button for 30 seconds the displayed temperature unit will be set 5 2 Airflow direction setting For details of the airflow ranges refer to Airflow direction range Up and down airflow direction setting Press to adjust the Up and down airflow direction Left and right airflow direction setting ...

Page 7: ...be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer 6 TIMER OPERATIONS NOTES When indicator on the indoor unit blinks set the clock and timer again This blinking shows that the internal clock go wrong due to an interru...

Page 8: ...wly NOTES In multi connection this function cannot be used Press to activate deactivate the Outdoor Unit Low Noise operation While the Outdoor Unit Low Noise operation is activated on the remote controller is displayed The setting is preserved even if the air conditioner is turned off Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Prog...

Page 9: ...personnel initially set to A If you do not press any buttons for 30 seconds after the custom code is displayed the display returns to the clock display In this case repeat the setting from step 2 Depending on the remote controller the custom code may return to A when replacing the batteries In this case reset the custom code as necessary If you do not know the air conditioner custom code try each ...

Page 10: ...t beyond the frame 10 Replace the air filter and close the intake grille Refer to steps 4 5 of Cleaning air filter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter 2 Remove the air filter Lift up the air filter and pull o...

Page 11: ...for the outdoor unit refer to the outdoor unit installation manual 12 OPTIONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard indicator on the indoor unit will blink Res...

Page 12: ...g set In this case the indoor unit fan may stop temporarily while the Cooling operation To cancel the Fan control for energy saving refer to page 7 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the set temperature In this case the ou...

Page 13: ...of Auto restart Reset the clock and timer settings 10 Test run operation for authorized personnel only Press to quit the test run 3 8 times 10 times Fast Refrigerant leakage suspicion Blowing operation is performed to prevent the refrigerant from accumulating Open the windows to ventilate the room and contact an authorized service personnel Press the button to stop the buzzer sound 5 times 4 times...

Reviews: