background image

PART No. 9378532090

OPERATION MANUAL

MODEL:

Português

E

λλη

vIk

ά

Italiano

Español

Français

Deutsch

English

Türkçe

Русский

* Please write down the model name.

(Refer to the rating label.)

* Bitte schreiben Sie den Modellnamen auf.

(Siehe Typenschild)

* Veuillez écrire le nom du modèle.

(Consultez l’étiquette des spéci

fi

 cations.)

* Anote el nombre de modelo.

(Consulte la etiqueta de cali

fi

 cación).

* Annotare il nome del modello.

(Fare riferimento all'etichetta delle speci

fi

 che).

Καταγράψτε

 

το

 

όνομα

 

μοντέλου

.

(

Ανατρέξτε

 

στην

 

ετικέτα

 

τεχνικών

 

στοιχείων

.)

* Registe o nome de modelo.

(Consulte a etiqueta de classi

fi

 cação.)

Запишите

 

название

 

модели

.

(

См

на

 

паспортной

 

табличке

.)

* Lütfen model ad

ı

n

ı

 not ediniz.

(Derece etiketine bak

ı

n

ı

z.)

OPERATION MANUAL

AIR CONDITIONER (Floor type)

Before using this product, read these instructions thoroughly 

and keep this manual for future reference.

BEDIENUNGSANLEITUNG

KLIMAANLAGE (Boden Typ)

Bevor Sie dieses Produkt verwenden, lesen Sie diese 

Anweisungen sorgfältig durch und bewahren Sie diese 

Anleitung für späteres Nachschlagen auf.

MODE D’EMPLOI

CLIMATISEUR (Type àu sol)

Avant d'utiliser ce produit, veuillez lire attentivement ces 

instructions. Conservez ce manuel pour référence future.

MANUAL DE FUNCIONAMIENTO

ACONDICIONADOR DE AIRE (Tipo suelo)

Antes de utilizar el producto, lea estas instrucciones detenida-

mente y conserve este manual para consultarlo en el futuro.

MANUALE DI ISTRUZIONI

CONDIZIONATORE D'ARIA (Tipo da pavimento)

Prima di utilizzare l'apparecchio, leggere attentamente 

le presenti istruzioni e conservare il manuale per poterlo 

consultare il futuro.

ΕΓΧΕΙΡΙΔΙΟ

 

ΛΕΙΤΟΥΡΓΙΑΣ

ΚΛΙΜΑΤΙΣΤΙΚΟ

 (

Επιδαπεδιου

 

τυπου

)

Προτού

 

χρησιμοποιήσετε

 

το

 

προϊόν

διαβάστε

 

προσεκτικά

 

τις

 

παρούσες

 

οδηγίες

 

και

 

φυλάξτε

 

το

 

παρόν

 

εγχειρίδιο

ώστε

 

να

 

μπορείτε

 

να

 

ανατρέχετε

 

σε

 

αυτό

 

στο

 

μέλλον

.

MANUAL DE FUNCIONAMENTO

AR CONDICIONADO (Tipo de chão)

Antes de utilizar este produto, leia atentamente estas instruções 

e guarde este manual para referência futura.

РУКОВОДСТВО

 

ПО

 

ЭКСПЛУАТАЦИИ

КОНДИЦИОНЕР

 

ВОЗДУХА

 (

Напольный

 

тип

)

Перед

 

эксплуатацией

 

устройства

 

внимательно

 

ознакомьтесь

 

с

 

данным

 

руководством

 

и

 

сохраняйте

 

его

 

для

 

использования

 

в

 

будущем

.

KULLANIM KILAVUZU

KL

İ

MA (Zemin tipi)

Bu ürünü kullanmadan önce verilen talimatlar

ı

 dikkatlice okuyun 

ve daha sonra tekrar faydalanmak üzere saklay

ı

n.

00_9378532090_OM.indb   Cover1

00_9378532090_OM.indb   Cover1

2020/8/31   16:43:47

2020/8/31   16:43:47

Summary of Contents for Suelo AGY25-KV

Page 1: ... EMPLOI CLIMATISEUR Type àu sol Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo suelo Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo da pavimento Prima di u...

Page 2: ...ng the power plug Then consult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning...

Page 3: ...places or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any other electrical products or household belongings under this product Dripping condensation from this product might get them wet and may cause damage or malfunction of your propert...

Page 4: ...each remote controller The setting must be done while the setting screen is displayed for each function The button is controllable only when the air conditioner is operating For Energy saving operation Refer to page 7 Activates or deactivates the Economy operation Battery loading and remote controller preparation R03 LR03 AAA x 2 5 7 6 4 8 1 2 3 1 3 Put batteries as shown in the figure above 4 Pre...

Page 5: ...d down airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the timer or clock settin...

Page 6: ...y setting C 3 Press to switch the temperature unit C F 4 Press to finish the setting If you do not press the button for 30 seconds the displayed temperature unit will be set 5 2 Airflow direction setting For details of the airflow ranges refer to Airflow direction range Up and down airflow direction setting Press to adjust the Up and down airflow direction Left and right airflow direction setting ...

Page 7: ...be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer 6 TIMER OPERATIONS NOTES When indicator on the indoor unit blinks set the clock and timer again This blinking shows that the internal clock go wrong due to an interru...

Page 8: ...wly NOTES In multi connection this function cannot be used Press to activate deactivate the Outdoor Unit Low Noise operation While the Outdoor Unit Low Noise operation is activated on the remote controller is displayed The setting is preserved even if the air conditioner is turned off Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Prog...

Page 9: ...personnel initially set to A If you do not press any buttons for 30 seconds after the custom code is displayed the display returns to the clock display In this case repeat the setting from step 2 Depending on the remote controller the custom code may return to A when replacing the batteries In this case reset the custom code as necessary If you do not know the air conditioner custom code try each ...

Page 10: ...t beyond the frame 10 Replace the air filter and close the intake grille Refer to steps 4 5 of Cleaning air filter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter 2 Remove the air filter Lift up the air filter and pull o...

Page 11: ...for the outdoor unit refer to the outdoor unit installation manual 12 OPTIONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard indicator on the indoor unit will blink Res...

Page 12: ...g set In this case the indoor unit fan may stop temporarily while the Cooling operation To cancel the Fan control for energy saving refer to page 7 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the set temperature In this case the ou...

Page 13: ...of Auto restart Reset the clock and timer settings 10 Test run operation for authorized personnel only Press to quit the test run 3 8 times 10 times Fast Refrigerant leakage suspicion Blowing operation is performed to prevent the refrigerant from accumulating Open the windows to ventilate the room and contact an authorized service personnel Press the button to stop the buzzer sound 5 times 4 times...