Control panel (on the SE700 and SE500)
Controls
46
U41858-J-Z126-1-76
2. The status indicator displays no error code. If an error code is displayed, notify
Customer Service of this error code.
Press the POWER ON key to begin powering up the system. The power-up sequence
begins. POWER ON lights up and the status indicator displays a sequence from 001
through 399 while powering up.
The system is ready when POWER ON lights up and the status indicator displays 000. If
the status indicator displays an error code, an error occurred while powering up. In this case
notify Customer Service of this error code.
5.3.2.3
STAND-BY key
This key is used to switch off the power supply of the entire /390 system. It is switched off
independently of an automatic power-on/off function.
v
CAUTION!
There is a risk of data loss. When standby mode is switched to (using the key or the
SVP frame), it is not guaranteed that system data can be written back. Terminate
applications which are running beforehand and shut down the operating system.
w
IMPORTANT!
In standby mode some of the circuits remain live!
Press the STAND-BY key to initiate system power-off. The power-off sequence begins.
While the system is powering off, the status indicator displays a sequence from 501 through
599. When the Server Unit is switched off, POWER ON flashes and the status indicator
display is empty.
Instead of using the key, the system can also be switched to standby using the SVP frame
(AU4) POWER STAND-BY/IMPL. See the "Server Unit /390" Operating Manual [
2
].
Summary of Contents for SE300
Page 1: ...Edition June 2015 English SE700 SE500 SE300 Basic Operating Manual FUJITSU Server BS2000 ...
Page 6: ...Contents U41858 J Z126 1 76 ...
Page 8: ...Introduction 8 U41858 J Z126 1 76 Figure 1 SE server SU700 ...
Page 26: ...Features System overview 26 U41858 J Z126 1 76 ...
Page 78: ...Switching the SE700 SE500 on and off Switching the server on and off 78 U41858 J Z126 1 76 ...