4-1
4. INTERFACE
4.1
Physical Specifications
4.2
SCSI Bus
4.3
Bus Phases
4.4
Commands
4.5
Status: STATUS phase (target initiator)
4.6
Messages
4.7
Command Sequence
4.8
Status Transition of Logical Unit
4.9
Error Table
4.10 Items for Specifying Window
This image scanner and the host are connected via an 8-bit parallel interface. The interface follows the
ANSI (American National Standards Institute) SCSI 2 (Small Computer System Interface 2) Revision 10c.
This chapter provides an overview of SCSI (minimum information necessary for understanding this
scanner), as well as descriptions peculiar to the scanner. For details of SCSI, refer to the ANSI standard,
The following terms are needed to understand this section.
SCSI device:
A host adapter or a target controller that can he attached to the SCSI bus
Initiator: An SCSI device (usually a host system) that requests an I/O process to be performed by
another SCSI device (a target).
Target:
An SCSI device that performs an operation requested by an initiator
Logical Unit:
A physical or virtual peripheral device that is addressable through a target
Range of support
1. System Configuration
This scanner operates under the multiinitiator, multitarget environment. An initiator function is not
provided. This scanner incorporates an integrated target and logical unit (image scanner).
SCSI-ID:0 to 7, variable by DIP switch Logical unit number (LUN): 000, fixed
2.Bus phases
This scanner supports all phases except reselection phase.
Summary of Contents for SCANPARTNER 600C
Page 1: ...Fujitsu ScanPartner 600C OEM Manual Version 1 0 Doc No 250 0081 0 Fujitsu Inc ...
Page 2: ...ii ...
Page 5: ...v 5 3 4 Group 3 error flowchart no paper in ADF paper tray 5 5 ...
Page 6: ......
Page 14: ...3 2 1 Remove the shipping retainer 2 Fasten the shipping retainer ...
Page 21: ...3 9 3 5 3 Readable area Feeding direction Unit mm Figure 3 5 ADF readable area 356 216 ...
Page 28: ......
Page 90: ......