background image

19

E

4.  Troubleshooting

4.1  Checkpoints

Most problems concerning the SCSI card occur during SCSI device connection or

setup.  If you have a problem while the card is in use, check these items first:

・ Are the SCSI cables and power cord properly connected?

・ Are all SCSI devices properly linked to a PCI bus slot that supports bus

mastering?

・ Is any SCSI ID used twice?

・ Are the terminators properly set?

・ Is the SERVER's BIOS setup correct?

・ Are the SCSI card and SCSI device parity settings all the same?

・ Is the Ultra SCSI support option enabled even though a non-Ultra SCSI

device is being used?

・ Is an external SCSI device other than the differential-type connected with this

SCSI card?

(This SCSI card is designed to be connected with the differential SCSI device

only.)

If you cannot resolve the problem after checking these points, proceed to the

following points:

・ Check to see if information changed during SCSI card setup has been set

correctly after the power has been turned on again.

・ An attempt was made to use the Format/Verify utility in the disk device, but a

pop-up dialog box containing the message "Unexpected SCSI Command

Failure" is displayed, and an error message appears.  In this case, it is assumed

that the utility has probably detected a problem, such as a disk device or disk

medium failure, preventing the utility from being executed.

You can determine the cause of and solution for a problem from the indicated sense

key information.  The values and meanings of the sense keys displayed most

frequently are given below.

− 02h - Not ready

Medium not ready for formatting.  Check to see if the medium has been inserted

into the drive and that it has spun up to speed.

Summary of Contents for PRIMERGY

Page 1: ...P3FY 1340 01 SCSIカード PG 123 SCSI Card PG 123 USER S GUIDE PRIMERGY J E ...

Page 2: ...い お使いになる前に 次のものが梱包されていることをお確かめください 万一足りないものがございましたら おそれいりますが お買い上げの販売 店または最寄りの弊社パーソナルエコーセンターまでお申し付けください ハードウェア 本カード PG 123 ドキュメント 取扱説明書 本書 その他 保証書 Adaptecは Adaptec社の登録商標です Microsoft Windows MS MS DOSは 米国Microsoft Corporationの米国および その他の国における登録商標です その他の各製品名は 各社の商標 または登録商標です その他の各製品は 各社の著作物です All Rights Reserved Copyright 富士通株式会社 2001 ...

Page 3: ...体の電源コードや本カー ドの外部接続コードを抜いてください そのまま使用する と 雷によっては機器破損 火災の原因となります 本カードをサーバ本体に着脱する際には 安全のためサーバ 本体および接続されている機器の電源を切り 電源プラグを コンセントから抜いた後で行ってください 電源を入れたま まカードの着脱を行うと 装置の故障 発煙などが起こる可 能性があり また感電の原因となります 機器を移動する場合は 必ず機器の外部に接続されている コード類 本製品に接続されているコード類を含む をすべ てはずしてください コード類が傷つき火災 感電の原因と なること 機器が落ちたり倒れたりしてケガの原因となるこ とがあります 製品は精密に作られていますので 高温 低温 多湿 直射 日光など極端な条件での使用 保管は避けてください ま た 製品を曲げたり 傷つけたり 強いショックを与えたり しないでく...

Page 4: ...2 1 接続の前に 3 2 2 接続方法 5 3 コンフィグレーション 7 3 1 サーバ本体のコンフィグレーション 7 3 2 SCSISelectユーティリティの起動と終了 8 3 3 本カードのコンフィグレーション SCSISelectユーティリティ 10 3 4 複数のSCSIカードの構成 18 4 トラブルシューティング 19 4 1 チェックポイント 19 4 2 BIOSエラーメッセージ 21 4 3 お問合せになる前に 22 ...

Page 5: ...さい 接続するSCSI デバイスがDifferential対応かSingle End対応かわからない場合は SCSIデ バイスの取扱説明書を参照してください 本カードはSCSISelectユーティリティが搭載されており カードの設定を容 易に変更することができます 概略仕様を以下に示します 概略仕様 メーカ型名 AHA 2944UW カード種類 SCSI 3準拠 バスインタフェース PCI V2 1準拠 外部インタフェース Ultra Wide Differential データ転送方式 バスマスターDMA SCSIコントローラ AIC 7880 SCSIチャネル数 カード1枚につき1チャネル 最大転送速度 同期 40MB s 非同期 6MB s コネクタ 内蔵SCSIデバイス用68ピンコネクタ 未サポート 内蔵SCSIデバイス用50ピンコネクタ 未サポート 外付SCSIデバイス用68ピンコ...

Page 6: ...SCSIデバイス用68ピンコネクタのみをサポートし ておりますので 他のSCSIコネクタへSCSIデバイスを接続しないでく ださい 本カード上のジャンパJ2およびジャンパJ4は ショート状態 デフォル ト設定 のまま 変更しないでください AIC 7880 SCSIプロトコルチップ ホスト アダプタ LED LEDコネクタ 内蔵SCSI デバイス用 50ピンコネクタ 内蔵SCSI デバイス用 68ピンコネクタ ジャンパJ2 およびジャンパJ4 外付SCSI デバイス用 68ピンコネクタ ...

Page 7: ...のIDは 降順で6 0と15 8の優先順位となります ポイント SCSI IDには SCSIデバイスを本カードにケーブル接続する順番を示す働 きはありません 本カードのIDは デフォルト設定のSCSI ID 7のままにしておくようにお奬め します 何らかの理由で 本カードのSCSI IDを変更しなければならない場合 は 3 3 本カードのコンフィグレーション SCSI Selectユーティリティ をお読みください ハードディスクやその他のSCSIデバイスのSCSI IDを変更 する場合は 各SCSIデバイスの取扱説明書を参照してください ポイント 本カードに接続されているSCSIデバイスからシステムをブートする場合 は SCSISelectユーティリティのBoot Target ID設定を ブートを開始し たいSCSIデバイスのSCSI IDと対応するようにします サーバ本体に複数のSCS...

Page 8: ...るため 本カード上のジャンパJ2およびジャンパJ4は ショー ト状態 デフォルト設定 のまま 変更しないでください 本カードでの終端 本カードのSCSIターミネータは SCSISelectユーティリティを使って設定し ます デフォルト設定の Automatic のまま変更しないでください ポイント 本カード上のジャンパJ2およびジャンパJ4をショート状態にしているため 本カード上のSCSIターミネータは 常に有効となります SCSIデバイスの終端 各SCSIデバイスの終端を有効にするか無効にするかを判断する方法について は それぞれのSCSIデバイスの取扱説明書をお読みください SCSIケーブル SCSIデバイスを接続するために必要なケーブルは 安全な運用を行うための 重要なコンポーネントですので 必ず富士通純正品をご使用ください ポイント 複数のSCSIデバイスを本カードに接続する場合は...

Page 9: ...rential対応外付SCSIデバイスのみをサポートして おります Single End対応SCSIデバイスは接続しないでください 本カードの取り付け 本カードを取り付けるには 下記の手順に従ってください ポイント 本カードなどの拡張カードをインストールするときの特別の操作や指示に ついては サーバ本体の取扱説明書を参照してください 1 サーバ本体と周辺装置の電源を切り 電源コードを外してください 2 サーバ本体のカバーを取り外します 3 バスマスタデータ転送機能をサポートする未使用の32ビットPCIスロット を捜します ネジを外し カードスロットの開口部を覆っているブラケッ トを外します ネジはサーバ本体に本カードを固定するときに使用する ので なくさないようにしまっておいてください 4 PCIスロットの中に本カードを差し込みます 接触部がPCIスロットにき ちんとはまるように しっかり...

Page 10: ...源を切り 電源コードを外してください 3 SCSIデバイスのSCSI IDとSCSIターミネータを設定します SCSIケーブ ルに接続される最端のSCSIデバイスのSCSIターミネータ設定を有効に し 他のSCSIデバイスのSCSIターミネータ設定は無効にします 4 SCSIケーブルの一端のコネクタを 本カードの外付SCSIデバイス用68ピ ンコネクタに接続します 5 SCSIケーブルの他端のコネクタを SCSIデバイスのコネクタに接続しま す 6 他のSCSIデバイスを接続する場合は それぞれ直前のSCSIデバイスに SCSIケーブルを接続していき すべてのSCSIデバイスが全体として ひ とつなぎになるように接続します ...

Page 11: ...ようにしてく ださい どのPCIスロットがそれぞれの番号に対応しているか確実にわから ない場合は サーバ本体の取扱説明書を参照してください サーバ本体のBIOSセットアップユーティリティにInterrupt Typeまたは Interrupt Lineオプションがある場合は Int AまたはInterrupt Type A を選択してあるか確認してください マザーボードのジャンパ設定を 変更しなければならない場合があります Triggering Interruptオプションがある場合は 必ずLevelを選択してくだ さい PCIスロットのバスマスタリング機能を有効 無効にするオプションが ある場合は 必ず有効を選択してください 個々のPCIスロットを有効 無効にするオプションがある場合は 本 カードがインストールされているPCIスロットを 有効にしてくださ い ISA EISAボードとPC...

Page 12: ...との間で切り換えるこ とができます ただし CRTディスプレイの機種によっては この機能が働かないものも あります 4 オプションを選択するには または キーを押し 選択したいオプ ションまでカーソルを移動し Enter キーを押します 5 Esc キーを押すことで いつでも1つ前の画面に戻ります ポイント Configure View Host Adapter Settingsを選択した場合 F6 キー を押すことでオリジナルのデフォルト値に回復します SCSISelectユーティリティの終了方法 1 メニュー画面に戻り Esc キーを押してください Exit Utility のメッ セージが表示されます メニュー画面は 上記の SCSISelectユーティ リティの起動方法 の 2 を参照してください Adaptec AHA 2944 Ultra W BIOS v c 1996 Ada...

Page 13: ...ソルを合わせ Enter キーを押し てください その後 Esc キーを押してください なお 設定値を変更していない場合は Save Changes Made のメッ セージは 表示されません 3 Exit Utility のメッセージが表示されたら yes にカーソルを合わ せ Enter キーを押します 4 Please press any key to reboot のメッセージが表示されたら いずれか のキーを押します 5 サーバ本体がリブートされます ポイント SCSISelectユーティリティ内の設定値を変更した場合は サーバ 本体をリブートしなければ 変更した設定値は有効となりませ ん ...

Page 14: ...I ID 7 SCSI Parity Checking Enabled Host Adapter SCSI Termination 4 Automatic Boot Device Configuration デフォルト設定 Boot Target ID 0 Boot LUN Number 1 0 SCSI Device Configuration 0 15 デフォルト設定 Initiate Sync Negotiation yes Maximum Sync Transfer Rate 3 40 0 Enable Disconnection yes Initiate Wide Negotiation 3 yes Send Start Unit Command 2 yes デフォルト設定の まま変更しないで ください Include in BIOS Scan 2 yes 1 Multiple ...

Page 15: ...Speedが Enabled およびInitiate Wide Negotiationが yes のとき Maximum Sync Transfer Rateの最大設定値は 40MB sです 各設定の説明 1 SCSI Bus Interface Definitions Host Adapter SCSI ID このオプションを選択することで 本カードのSCSI IDを設定すること ができます デフォルトの設定はSCSI ID 7 です この場合 SCSIバスの中でSCSIカードが最も高い優先順位を持つことになりま す 本カードのSCSI IDの設定は7のまま変えないようにすることをお 奬めします SCSI Parity Checking このオプションを選択することにより SCSIバスでデータが正確に転 送されているか 本カードが検査するかどうかを決めることができま す デフォルト設定は...

Page 16: ... Configuration 0 15 このオプションにより SCSIバスにある各SCSIデバイスに特定のパラメータ を構成することができます SCSIデバイスを構成するには そのSCSIデバイ スに割り当てられているSCSI IDを知っていなければなりません Initiate Sync Negotiation このオプションを使用することで SCSIデバイスと本カードの間での 同期データ転送ネゴシエーション 同期ネゴシエーション を 本 カードにより起動できるようにするかどうかを決めることができま す デフォルト設定は yes です 同期ネゴシエーションはSCSIの機能で この機能により本カードと本 カードに接続されているSCSIデバイスが同期モードでデータを転送す ることが可能となります 同期データ転送は非同期データ転送より高 速です SCSIデバイスがこの機能を起動した場合は 必ず本...

Page 17: ...itiate Wide Negotiationが yes に設 定されている場合 SCSIデバイスがFastWideSCSIデバイスの場合 は 最高値は20 0 MB sとなります 本カードが同期データ転送をネゴシエーションしないように設定され ている場合は つまり Initiate Sync Negotiationの開始が no に設定 されている場合 最高同期転送速度は本カードがネゴシエーション 中にSCSIデバイスから受け入れる最高速度となります Enable Disconnection このオプションにより 本カードを使用することで SCSIデバイスを SCSIバスからディスコネクト 切断 できるかどうかを指定すること ができます ディスコネクトが可能になっている場合 SCSIデバイス が一時的にディスコネクトされている間 本カードはSCSIバスを使い 他の操作を行うことができます...

Page 18: ...となります ほとんどのSCSIデバイスでは コマンドに対して応答できるように 前もってジャンパを設定してお かなければなりません Include in BIOS Scan このオプションを yes にすることで デバイスドライバソフト無し でも SCSIバスに接続されたInt 13hデバイス ハードディスクドライ ブ が Host Adapter BIOSにより認識されて システムの装置として 組み込まれます デフォルト設定は yes です no に設定した場合には SCSIデバイスを制御するために 別途デ バイスドライバソフトが必要になります 4 Advanced Configuration Options アドバンストコンフィグレーションの設定は どうしても変更しなければな らない場合を除き 変更しないでください Reset SCSI Bus at IC Initialization ...

Page 19: ...Sを必要 としない場合は Host Adapter BIOSは Disabled にしてください Support Removable Disks Under BIOS as Fixed Disks このオプションを使用することで 本カードでどのリムーバブル メ ディアドライブをサポートするか制御することができます デフォル ト設定は Boot Only です このオプションには下記の選択項目があ ります Boot Only ブートデバイスとして指定されるリムーバブル メディアドライブ のみが ハードディスクドライブとして処理されます All Disks Host Adapter BIOSがサポートするすべてのリムーバブル メディア ドライブがハードディスクドライブとして処理されます Disabled リムーバブル メディアドライブが ハードディスクドライブとし て処理されることはありません...

Page 20: ... 選択するパーティ ションサイズは 8MBの倍数でなければなりません 8MBの倍数以外のサ イズを要求すると fdiskが8MBの倍数に最も近い数字に丸めます Display Ctrl A Message During BIOS Initialization このオプションにより システムブートアップ時に Press Ctrl A for SCSISelect TM Utility のメッセージを画面に 表示するかどうか決めることができます メッセージ画面は 3 2 SCSISelectユーティリティの起動と終了 SCSISelectユーティリティ の起動方法の1 を参照してください デフォルト設定は Enabled です この設定が D i s a b l e d に設定されている場合には Press Ctrl A for SCSISelect TM Utility のメッセー ジは画面...

Page 21: ...CSIディスクユーティリティを使用したい場合は SCSISelectユーティリ ティ開始後に表示されるメニューからSCSI Disk Utilitiesオプションを選択し てください 3 2 SCSISelectユーティリティの起動と終了 をご参照くだ さい 一度オプションが選択されると SCSISelectユーティリティは直ち にSCSIバスをスキャンし すべてのSCSI IDとIDが割り当てられたSCSIデバ イスを並べたリストを表示します 特定のIDとデバイスを選択すると 小さいメニューが表示され Format Disk とVerify Disk Mediaのオプションが表示されます Format Disk このユーティリティを使用することで ハードディスクドライブで低 レベルフォーマットを行うことができます ほとんどのSCSIディスク デバイスは 工場で事前にフォーマットされていま...

Page 22: ... いつでも このユーティリティを終了させることができます 3 4 複数のSCSIカードの構成 サーバ本体に複数のSCSIカードをインストールし 複数のSCSIチャンネルを 使用することができます インストールとセットアップはSCSIカードを1つ導 入する場合と同じです ただし サーバ本体により使用可能なPCIバススロッ トの数に制限があります サーバ本体に複数のSCSIカードを使用する場合は 下記の点を配慮してくだ さい SCSISelectユーティリティを実行しているときには ユーティリティが 複数のSCSIカードをサーバ本体で使用していると判断した場合 各 SCSIカードのPCIバス番号とPCIデバイス番号を表示します 設定を変更したい場合は SCSIカードのPCIバス番号とPCIデバイス番 号を と の矢印キーで選択し Enter を押します ...

Page 23: ...IカードとSCSIデバイスのパリティ機能はすべて同じ設定になって いますか UltraSCSI対応でないデバイスのみを使用しているのにかかわらず Support for Ultra SCSI Speedを Enabled にしていませんか Differential対応以外の外付SCSIデバイスを接続していませんか 本カードは Differential対応専用のSCSIカードです 以上の点を確認しても 問題点が解決しない場合は 下記の説明に進んでく ださい SCSIカードをセットアップするに当たって変更した内容が 電源を再 投入した後も正しく設定されているか確認しましたか Format Verifyユーティリティをディスクデバイスで使用しようとした が Unexpected SCSI Command Failure というメッセージのポップ アップボックスが表示され エラーメッセージが出され...

Page 24: ...ださい 03h Medium error ディスクメディアに欠陥があると推定されます 欠陥がリムーバブル メ ディアドライブにある場合は 別のディスクメディアを使用するようにし てください ハードディスクドライブに欠陥がある場合は ディスク自体 が物理的に損傷していることが考えられます SCSISelectユーティリティ でメディアを検査し フォーマットしてください 04h Hardware error ディスクドライブに欠陥があると推定されます ディスクドライブのメー カーに問い合わせてください 06h Unit attention リムーバブル メディアが書き込み保護されている可能性があります 書 き込み保護機能を無効にし 再度ユーティリティを実行します ...

Page 25: ...tユーティリティの Send Start Unit Command を yes に設 定してみてください メッセージが表示されたままになっている場合は ディスクドライブのメー カーの指示に従い 電源のスイッチがオンになった場合にドライブがスピン アップするように設定してください Start unit request failed BIOSはSCSIデバイスにスタートユニットコマンドを送ることができません SCSISelectユーティリティを実行し そのSCSIデバイスの Send Start Unit Command を no にしてください Time out failure during 予期しないタイムアウトが発生しました SCSIバスの終端をチェックしてく ださい 本カードからSCSIケーブルを外し サーバ本体を起動してみてくだ さい サーバ本体が問題なく再起動すれば SCSIバスの...

Page 26: ...以上のチェックポイントに問題がない場合には 弊社のサポート窓口までお 問い合せください その際には 迅速なサポートをおこなうため 以下の事 柄を事前に確認しておいてください 不具合の具体的な内容と発生までの手順 サーバ本体のモデル名および型名 サーバ本体に搭載されているカードの種類と各カードの設定 オペレーティングシステムの製品名と版数 使用しているデバイスドライバの版数 その他 購入時からのハードウェアおよびソフトウェアの変更点など ...

Page 27: ...If any item is missing contact the sales outlet where you purchased the product Hardware This card PG 123 Documents User s Guide this manual Adaptec is a registered trademark of Adaptec Inc Microsoft Windows MS and MS DOS are trademarks of Microsoft Corp of the United States regis tered in the United States and other countries Other product names are trademarks or registered trademarks of their re...

Page 28: ... or fire To ensure safety before installing or removing the card turn off the power to the SERVER and peripheral equipment then unplug the power cord from the power outlet Installing or removing the card while the power is on may cause electric shock equipment malfunction or smoke When moving equipment disconnect all external cables attached to the equipment including cables connected to this prod...

Page 29: ...3 Configuration 7 3 1 SERVER Configuration 7 3 2 Activating and terminating the SCSISelect Utility 8 3 3 This Card Configuration SCSISelect Utility 10 3 4 Configuring Two or More SCSI Cards 18 4 Troubleshooting 19 4 1 Checkpoints 19 4 2 BIOS Error Messages 21 4 3 Before Contacting Us 22 ...

Page 30: ...iv ...

Page 31: ...tructions of the SCSI device to be connected This card incorporates the SCSISelect utility which lets you easily change the card settings The summarized specifications are given below Summarized specifications Manufacturer s device type AHA 2944UW Card type SCSI 3 compliance 1 Bus interface PCI V2 1 compliance External interface Ultra Wide Differential Data transfer system Bus master DMA SCSI cont...

Page 32: ...use the other SCSI connectors for connecting any SCSI device Leave both the jumpers J2 and J4 of this card in their respective default settings short circuited without fail Jumper J2 Jumper J4 68 pin connector for built in SCSI device 50 pin connector for built in SCSI device 68 pin connector for external SCSI device LED connector Host adapter LED AIC 7880 SCSI protocol chip ...

Page 33: ...I ID7 has the highest priority for SCSI devices connected to this card The priority of the remaining IDs are from 6 to 0 and from 15 to 8 in descending order Note SCSI IDs do not indicate the order in which the cables of SCSI devices should be connected to this card We recommend that you leave this card ID set to its default setting of SCSI ID 7 If you need to change the SCSI ID of this card read ...

Page 34: ...ed always be sure to leave both the jumpers J2 and J4 of this card in their respective default settings short circuited This card termination This card terminator is set using the SCSISelect utility The default setting is Automatic which sets termination automatically We recommend that you leave the terminator set to the default Automatic setting Note All the SCSI terminators of this card are alwa...

Page 35: ... any single end SCSI device to this card Installing this card Follow these instructions to install this card Note For the specifics of installing an expansion card such as this card refer to the SERVER s documentation 1 Turn off the power to your SERVER and peripherals and disconnect the power cords 2 Remove the cover from the SERVER 3 Locate an unused 32 bit PCI slot the slot must support Bus Mas...

Page 36: ...ator setting of SCSI device that is connected at the end of SCSI cable Then invalidate the terminator settings of other SCSI devices 4 Connect the connector of the SCSI cable to the SCSI 68 pin 16 bit connector of this card 5 Connect the connector at the other end of the SCSI cable to the connector of the SCSI device 6 To connect other SCSI devices connect the SCSI cable from each device to the pr...

Page 37: ...documentation If there is an Interrupt Type or Interrupt Line option in the BIOS setup utility for the SERVER check to see if Int A or Interrupt Type A has already been chosen Change the jumper setting of the motherboard if required If there is a Triggering Interrupt option choose Level If there is an option to enable or disable the bus mastering function of the PCI slot be sure to choose Enabled ...

Page 38: ...vailable 4 To select the option move the cursor to the desired option by pressing the or key then press the Enter key 5 Pressing the Esc key can restore to the previous screen at any time Note When Configure View Host Adapter Settings is selected settings return to the default value by pressing the F6 key Termination of SCSISelect utility 1 Restore the menu screen and press the Esc key A message E...

Page 39: ...ey Finally press Esc key If the setting value is not changed a message Save Change Made is not displayed 3 When Exit Utility is displayed move the cursor to Yes and press the Enter key 4 If Please press any key to reboot is displayed press any key 5 The SERVER is rebooted Note If the setting value in the SCSISelect utility is changed the changed value is not effective unless the SERVER is rebooted...

Page 40: ...rface Difinitions Default setting Host Adapter SCSI ID 7 SCSI Parity Checking Enabled Host Adapter SCSI Termination 4 Automatic Boot Device Configuration Default setting Boot Target ID 0 Boot LUN Number 1 0 SCSI Device Configuration 0 to 15 Default setting Initiate Sync Negotiation yes Maximum Sync Transfer Rate 3 40 0 Enable Disconnection yes Initiate Wide Negotiation 3 yes Send Start Unit Comman...

Page 41: ...r SCSI ID Selecting this option allows you to set the SCSI ID of this card The default setting is SCSI ID 7 This card has the highest priority on the SCSI bus We recommend that you leave this card ID set to 7 SCSI Parity Checking Selecting this option allows you to determine whether data is transferred accurately on the SCSI bus or whether this card checks the parity The default setting is Enabled...

Page 42: ...ne whether to initiate synchronous data transfer negotiation Sync negotiation between the SCSI device and this card using this card The default setting is yes Sync negotiation is a SCSI function that allows this card and the device connected to this card to transfer data in synchronous mode The synchronous data transfer rate is higher than the asynchronous data transfer rate When the SCSI device i...

Page 43: ...to no the maximum synchronous transfer rate is the maximum rate at which this card accepts data from a SCSI device during negotiation Enable Disconnection This option allows you to specify whether to enable the SCSI device so that it can be disconnected from the SCSI bus by using this card If disconnection is enabled this card can perform another operation using the SCSI bus while the SCSI device ...

Page 44: ...ply When it is set to no all SCSI devices are started simultaneously at bootup time Most SCSI devices need to have their jumpers preset to respond to this command Include in BIOS Scan When this option is set to yes the Int 13h device hard disk drive connected with the SCSI bus is recognized by the Host Adapter BIOS and incorporated into the system as a system unit regardless of installation of a d...

Page 45: ...his Card Configuration SCSI Select Utility 1 Configure View Host Adapter Settings When you boot the system from a SCSI device connected to this card be sure to Enabled Host Adapter BIOS All peripherals on the SCSI bus are controlled by the device driver If you do not need Host Adapter BIOS Disabled Host Adapter BIOS Support Removable Disks Under BIOS as Fixed Disks Using this option allows you to ...

Page 46: ... should be same as that of the SERVER When you create partitions on a disk drive with a capacity greater than 1 GB use the MS DOS fdisk utility in the usual way Since extended translation can increase the cylinder size to 8 MB you must set partition sizes in multiples of 8 MB If you set a size other than a multiple of 8 MB the fdisk utility rounds the size up to the nearest multiple of 8 MB Displa...

Page 47: ...rted Refer to the chapter 3 2 Activating and terminating the SCSI Select Utility When the option is selected SCSISelect Utility immediately scans the SCSI bus and displays a list of all SCSI IDs and the device assigned to each ID When you select a specific ID and device a small menu appears displaying the options Format Disk and Verify Disk Media Format Disk This utility allows you to perform a lo...

Page 48: ...ct the number of PCI bus slots available When you use two or more SCSI cards for a SERVER note the points below When you execute the SCSISelect utility if the utility recognizes that two or more SCSI cards are used in the SERVER it displays the PCI bus number and PCI device number for each SCSI card Use the arrow keys and to select the PCI bus number and device number of the SCSI card whose settin...

Page 49: ...ifferential SCSI device only If you cannot resolve the problem after checking these points proceed to the following points Check to see if information changed during SCSI card setup has been set correctly after the power has been turned on again An attempt was made to use the Format Verify utility in the disk device but a pop up dialog box containing the message Unexpected SCSI Command Failure is ...

Page 50: ... hard disk drive fails it is assumed that the disk itself is physically damaged Use SCSISelect utility to check and format the medium 04h Hardware error The disk drive failed Contact the disk drive manufacturer 06h Unit attention A removable medium may be write protected Disable write protection and reexecute the utility ...

Page 51: ...elect utility to yes If the message is still displayed follow the disk drive manufacturer s instructions and set the drive to rotate when the power switch is ON Start unit request failed BIOS cannot send a Start Unit command to a device Run the SCSISelect utility and no Send Start Unit Command for that device Time out failure during An unexpected time out occurred Check the SCSI bus termination Di...

Page 52: ...t make a list of the following items Detailed information about the failure and your actions immediately before the failure Model and type of the SERVER Types of cards installed in the SERVER and the settings for each card Product name and version and level of operating system Version and level of the device driver used Modifications to hardware and software you purchased ...

Page 53: ...na Move the equipment away from the receiver Plug the equipment into an outlet on a circuit different from that to which the receiver is powered If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions CAUTION Only equipment certified to comply with Class B computer input output devices terminals printers etc should be attached to thi...

Page 54: ...MEMO ...

Page 55: ...y liability for infringement of third party patents and any other rights caused by abuse of information provided in this document Transcription without prior permission is prohibited Any manual which has missing pages or which is incorrectly collated will be replaced SCSIカード PG 123 SCSI Card PG 123 取扱説明書 User s Guide P3FY 1340 01 00 発 行 日 2001年2月 Publication date February 2001 発行責任 富士通株式会社 Publish...

Page 56: ...このマニュアルは再生紙を使用しています ...

Reviews: