TX200 S6
Operating Manual
57
Hardware installation
V
CAUTION!
Ensure that the safety lock has been inserted before the server is
inserted (see
figure 5 on page 54
).
V
CAUTION!
At least two people are needed to position the server in the rack.
(For the Japanese market, please refer to "
安全上の注意およびその他の
重要情報
".)
Ê
Extend the telescopic rails completely to the front (1).
I
They must click into place so that they can no longer be moved.
Ê
Lower the server from above onto the projecting telescopic rails (2), (3). As
you do this, the locking bar (4) engages.
Ê
Push the locking mechanism of both telescopic rails up (5).
Ê
For a final function test, slide the server in and out at least twice.The rails
should move smoothly.
Ê
Push the server as far as it will go into the rack (6).
Ê
Fasten the server to the rack (7) using the two knurled screws (front panel).
Ê
Route the cables as described in the technical manual for the rack in
question with the server pushed in.
4.3.3
Installation in 3rd party racks
I
The support systems from Fujitsu are suitable for use in any 3rd party
racks for standard servers (installation depth 714 - 785 mm) without
restrictions.
Ê
Refer to the manual from the rack manufacturer for details of the mechanical
installation and the climatic conditions.
V
CAUTION!
When installing in 3rd party racks, it must be ensured that an air flow
from the front to the back of the rack is guaranteed.
Ê
Fit the required original parts (support bracket or cable management
system).
Summary of Contents for PRIMERGY TX200 S6
Page 1: ...Operating Manual English PRIMERGY TX200 S6 Server Operating Manual Edition July 2010 ...
Page 6: ...Operating Manual TX200 S6 ...
Page 64: ...64 Operating Manual TX200 S6 Hardware installation ...
Page 84: ...84 Operating Manual TX200 S6 Property and data protection ...
Page 90: ......
Page 120: ...120 Operating Manual TX200 S6 Appendix server specification ...
Page 126: ......