Disconnect the fan cable from the connector FAN2 (if there is a second fan
cable, disconnect this from FAN4) on the system board (see the technical
manual for the system board D2799).
Ê
Press the two green locks of the air duct together (1).
Ê
Press the green lock of the air duct in the direction of the arrow (2).
Ê
Lift the air duct with the integrated system fan 2 (and 4) up and out (3).
8.2.1.3
Removing system fan 1 (and 3)
Ê
Remove system fan 2 (and 4) (see
"Removing system fan 2 (and 4)" on
page 105
).
Figure 30: System fan 1 and system fan 1&3
The standard system fan 1 is shorter and has just one fan cable; the redundant
system fan 1&3 is taller (as 2 fans are integrated internally) and has two fan
cables.
The procedure for installing and removing both system fans is identical except
for connecting the fan cables.