TX200 S6
Operating Manual
109
CSS components
8.2.3
Replacing the system fan
V
CAUTION!
Since the standard system fans 1 and 2 are not redundant, these system
fans have to be replaced immediately.
If one of the four redundant system fans (1&3 and 2&4) fails, one of the
two predetermined fans (system fan 3 and 4) increases its power to
ensure that the server is cooled properly. The redundant system fans
should be replaced as soon as possible.
8.2.3.1
Replacing system fan 2 (and 4)
Ê
Remove the defective system fan 2 (and 4) (see
"Removing system
fan 2 (and 4)" on page 105
).
Ê
Install the new system fan 2 (and 4) (see
"Installing system fan 2 (and 4)" on
page 113
).
8.2.3.2
Replacing system fan 1 (and 3)
Ê
Remove the defective system fan 1 (and 3) (see
"Removing system fan 1
(and 3)" on page 106
).
Ê
Install the new system fan 1 (and 3) (see
"Installing system fan 1 (and 3)" on
page 112
).