Hard disk drives
The server is shipped with one of the following drive cages:
–
For up to four 3.5-inch SAS/SATA hard disk drives:
Up to four SAS/SATA HDD modules can be used in the drive cage. Each
HDD module can accommodate a SAS/SATA hard disk drive with a
maximum height of 1 inch. The module is connected to the SAS/SATA
backplane wirelessly. This allows HDD modules to be plugged in and pulled
out easily.
As an option, a hard disk extension box (with a maximum of two SAS/SATA
HDD modules) can be installed (see section
"Accessible drives" on
page 18
).
I
Up to four SATA hard disk drives are controlled by the onboard SATA
controller. An additional SAS/SATA RAIDcontroller must be installed
to control additional SATA hard disk drives or SAS hard disk drives.
–
For up to eight 2.5-inch SAS/SATA hard disk drives:
Up to eight SAS/SATA HDD modules can be used in the drive cage. Each
HDD module can accommodate an SAS/SATA hard disk drive with a 2.5-
inch format. The modules are connected to the SAS/SATA backplane
wirelessly. This allows HDD modules to be plugged in or pulled out easily.
As an option, a hard disk extension box (with a maximum of eight SAS/SATA
HDD modules) can also be installed (see section
"Accessible drives" on
page 18
).
I
Up to eight SAS/SATA hard disk drives are controlled by the
SAS/SATA RAID controller already installed.The hard disk extension
box for 2.5-inch SAS hard disk drives requires an additional
SAS/SATA RAID controller.
If the server has the corresponding RAID configuration, HDD modules can also
be replaced during operation.
Summary of Contents for PRIMERGY TX200 S6
Page 1: ...Operating Manual English PRIMERGY TX200 S6 Server Operating Manual Edition July 2010 ...
Page 6: ...Operating Manual TX200 S6 ...
Page 64: ...64 Operating Manual TX200 S6 Hardware installation ...
Page 84: ...84 Operating Manual TX200 S6 Property and data protection ...
Page 90: ......
Page 120: ...120 Operating Manual TX200 S6 Appendix server specification ...
Page 126: ......