![Fujitsu PRIMERGY TX200 S2 User Manual Download Page 241](http://html.mh-extra.com/html/fujitsu/primergy-tx200-s2/primergy-tx200-s2_user-manual_121257241.webp)
241
PRIMERGY TX200 S2 User’s Guide
8
Con
figurin
g Hardwa
re
a
nd utili
ties
8.2.8 Advanced System Configuration Submenu
This menu performs CPU, memory and USB related settings.
table: Items on the Advanced System Configuration Submenu
Item
Setting
Description
PCI Bus Parity Checking
Enabled (Fixed parameter)
Sets whether to enable or disable the PCI bus parity
checking.
Memory Redundancy
• Disabled (at the time of
purchase)
• Sparing
Sets whether or not to use spare memory.
Remap PCI Memory Gap
• Disabled (at the time of
purchase)
• Enabled
Sets whether to enable or disable the PCI Memory
Gap. When installing 4GB or more memory, set to
[Enabled].
CPU Mismatch Detection
Enabled (Fixed parameter)
Sets whether to enable or disable checking the CPU
type and frequency.
CPU Timeout Counter
Disabled (Fixed
parameter)
The server does not support this yet.
CPU Frequency (GHz)
Automatic (Fixed
parameter)
Displays the options [Installed CPU frequency or
less] and [Automatic].
Hyper-Threading
• Disabled
• Enabled (at the time of
purchase)
Sets whether or not to run one CPU as a dual-
processing CPU. The setting [Enabled] may
enhance processing performance by allowing
maximum use of the processor resources.
Limit CPUID functions
Disabled (Fixed
parameter)
Configures the CPU internal setting.
CPU Thermal Management
Enhanced (Fixed
parameter)
Configures the CPU internal setting. This item is
displayed only when using the optional 3.6GHz
CPU.
CPU Halt Mode (C1E)
Standard (Fixed
parameter)
Configures the CPU internal setting.
PhoenixBIOS Setup Utility
Item Specific Help
Select Item
Select Menu
Change Values
Select > Sub-Menu
-/+
Enter
F1
Esc
Help
Exit
F9
F10
Setup Defaults
Save and Exit
Advanced
Security
Server
Exit
Main
Advanced System Configuration
PCI Bus Parity Checking:
Memory Redundancy:
Remap PCI Memory Gap:
CPU Mismatch Detection:
CPU Timeout Counter:
CPU Frequency(GHz):
Hyper-Threading:
Limit CPUID functions:
CPU Thermal Management:
CPU Half Mode(C1E):
NX Memory Protection:
CPU MC Status Clear:
Enhanced SpeedStep:
CPU Clock Throttling Delay:
USB Host Controller:
USB2.0 Host Controller:
USB BIOS Legacy Support:
[Enabled]
[Disabled]
[Disabled]
[Enabled]
[Disabled]
[Automatic]
[Enabled]
[Disabled]
[Enabled]
[Standard]
[Disabled]
[Next Boot]
[Disabled]
[No Delay]
[Enabled]
[Enabled]
[Disabled]
Summary of Contents for PRIMERGY TX200 S2
Page 6: ...6 ...
Page 42: ...42 Chapter 1 Overview ...
Page 58: ...58 Chapter 2 Checking before OS Installation ...
Page 112: ...112 Chapter 3 OS Installation Using ServerStart ...
Page 132: ...132 Chapter 4 Manual OS Installation ...
Page 166: ...166 Chapter 5 Operations after OS Installation ...
Page 312: ...312 D Recycling ...
Page 316: ...316 ...