Fit assembly kit and rack-mount the server
If the rack model is integrated in an already existing installation that
receives power from an industrial (public) power supply network with the
IEC309 connector, the (public) power supply protection must comply with
the requirements for the non-industrial (public) power supply networks for
the type A connector.
The server must not be mounted into the height unit at the top of a rack,
because in this case it would not be possible to change the boards when
the slide-in unit is pulled out as far as possible.
As the server may weigh up to 28 kg, at least two people are required in
order to install it into the rack.
The rack may tip over if more than one heavy unit is removed.
Preparation
–
In order to make the rack model lighter during the installation, all redundant
power supply modules and SCSI hard disk drives should be removed.
Check, if the drives are marked, so that they later can be replaced
into their original slots.
Rack installation
Two rack mounting kits are available:
S26361-F2734-E/L31:
Mounting kit for mounting servers in:
–
19" racks (DataCenter and PRIMECENTER rack)
–
all server racks confirming to EIA standard EIA-310-D
S26361-F1331-L7
Mounting kit for mounting servers in:
–
42/23 U rack
!
!