34
Operating Manual
RX900
S2
Functional overview
Ambient conditions
Condensation during operation must be avoided!
Ventilation clearance
At least 200 mm on the front and rear.
Electrical values
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
10 °C .... 35 °C
Transport (2K2)
-25 °C .... 60 °C
Humidity
10% ... 85% (non condensing)
Power supply
configuration
– Up to 4 hot-plug power supply units
– Base unit equipped with 2 power supply units
– Redundancy concept only applicable for the
mains voltage 200 - 240 V: Basic configuration:
1+1 redundancy; AC redundancy available with
a 1+1 or 2+2 redundant configuration.
Max. output of single
power supply
2000 W
Hot-plug power supply
redundancy
Yes
Rated voltage range
100 - 240 V
Rated frequency range
50 - 60 Hz