RX1330 M3
Upgrade and Maintenance Manual
327
Appendix
The LEDs have the following meaning:
LED Indicator
Meaning
A - Identification blue on
The server has been highlighted using
iRMC web frontend, ServerView
Operations Manager or the ID button on
the front panel for easy identification.
blue flashing
The server has been highlighted using
IRMC (AVR) when local VGA off for easy
identification.
B - CSS
(Customer Self
Service)
off
No critical event detected (CSS
component).
orange on
Prefailure event detected (CSS
component).
orange flashing CSS component failure detected.
C - GEL
(Global Error
LED)
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange flashing Non CSS component failure detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server management
software
D - Memory
off
memory module running
orange on
memory module failure
E - AUX power
off
orange on
voltages okay
F - System fan
off
system fan running
orange on
system fan failure
G - PCI card
off
PCI card okay
orange on
PCI card failure (PCI card installed on riser
card)
Summary of Contents for PRIMERGY RX1330 M3
Page 20: ...Upgrade and Maintenance Manual RX1330 M3 Contents ...
Page 48: ...48 Upgrade and Maintenance Manual RX1330 M3 Important information ...
Page 70: ...70 Upgrade and Maintenance Manual RX1330 M3 Basic hardware procedures ...
Page 132: ...132 Upgrade and Maintenance Manual RX1330 M3 Power supply unit PSU ...
Page 178: ...178 Upgrade and Maintenance Manual RX1330 M3 Hard disk drive HDD solid state drive SSD ...
Page 184: ...184 Upgrade and Maintenance Manual RX1330 M3 Fans ...
Page 222: ...222 Upgrade and Maintenance Manual RX1330 M3 Expansion cards and backup units ...
Page 244: ...244 Upgrade and Maintenance Manual RX1330 M3 Processor CPU ...
Page 310: ...310 Upgrade and Maintenance Manual RX1330 M3 System board and components ...