CHAPTER 4 Installation of Operating System and bundled software
4.3 Procedure to install Windows in SAN/iSCSI storage device
62
CA92344-0536-04
4.3.2 Preparation for installation
The following preparations are done.
1.
The following disk images should be prepared.
Media of Windows operating system
2.
FC cable is made a single path (Connection of only 1 FC cable).
4.3.3 Installation of operating system
Operating system installation by SVIM is explained.
There are the following types in the operating system installation by SVIM. For the detailed procedure of the respective
modes, see ServerView Suite ServerView Installation Manager.
TABLE 4.1
Operating system installation by SVIM
Mode
Function Overview
Objective
Quick
Mode
The operating system can be installed in the state recommended by
Fujitsu by only executing the required minimum settings.
This mode is used when
operating system is easily
installed.
Guide
Mode
It is set according to wizard set up information. The information that was
set, is saved in a configuration file and can be used at the time of re-
install
This mode is used for
advanced setting of RAID and
operating system.
All the inserted windows are examples of display and the contents displayed by the system configuration, etc. are different.
Operations
1.
Make the settings by which the ServerView Suite DVD is booted from the virtual media for the partition.
For settings, see“1.6.2 Remote control operation (BMC)”
of PRIMEQUEST 2000 series Administration Manual
(CA92344-0537).
2.
The power supply of the partition is turned on.
Notes
The UEFI boots or the Legacy boots can be selected in the following procedure.
a.
Select [Force boot into EFI Boot Manager] in MMB Web-UI.
b.
Turn on the power supply of partition
c.
The menu is selected in the following order by the Boot Manger front page. [Boot Maintenance Manager]- [Boot
Options]- [Change Boot Order]- [Change the order]
d.
For UEFI aware OS, UEFI: Fujitsu Virtual CDROMx xxx is set at the upper-most step.
For Legacy OS, Fujitsu Virtual CDROMx xxx is set at the upper-most step.
For the Boot order setting method, see “
Change of priority level (Change Boot Order)” of “3.5.2 [Boot
Options] menu” of PRIMEQUEST 2000 series Tool Reference (CA92344-0539).
e.
Select [Commit Changes and Exit]..
f.
Return to the front page pushing the escape key twice.
g.
Select [Boot Manager].
h.
For UEFI aware OS, select UEFI: Fujitsu Virtual CDROMx xxx.
For Legacy OS, select Fujitsu Virtual CDROMx xxx.
3.
Windows Boot Manager is displayed. Select the first menu in Windows Boot Manager.
4.
After a period of time, the language selection window is displayed. In case of English, select "English".
5.
Click the "Next" button without setting anything on the initial display window.
6.
[Deployment] is selected by the [To Welcome ServerView Installation Manager].
7.
Installation mode is selected, operating system to be installed is selected and the operating system is set.
Remark
IP address of LAN cannot be set by the setting of operating system. Set the IP address after operating system
installation.
8.
Click “Installation start-up”.
The installation starts.
9.
It is replaced to the installation medium of operating system according to the SVIM instruction.