5.4 Command Protocol
C141-E262
5-183
5.4.6 Native Command Queuing protocol
Native Queued commands include the following commands:
•
READ FP DMA QUEUED
•
WRITE FP DMA QUEUED
An outline of the command queuing protocol is as follows:
1) After the device receives a Native Queued command, if the command is
executable, the device sends to the host the RegDH FIS with the settings of I
bit = 0, BSY bit = 0, and DRQ bit = 0, and it places the command in the
command queue. Otherwise, the device sends the RegDH FIS to the host to
report an error.
2) If the device receives a command that is not a Native Queued command
during command queuing, the device sends to the host the RegDH FIS with
the settings of ERR bit = 1, I bit = 1, BSY bit = 0, DRQ bit = 0, and Error
register = 0x04 to report an abort.
3) When the device is ready to send data for the data transfer of the READ FP
DMA QUEUED command, it sends to the host the DMA Setup FIS with the
settings of TAG = #, D bit = 1, I bit = 0, and A bit = 0, and it then sends the
Data FIS to the host. (The Data FIS is transferred in units of up to 8 KB).
4) When the read data transfer requested by the command is completed and the
command is completed normally, the bit in the SActive field in the SetDB
FIS corresponding to the tag number of the completed command is set by the
device, and the device sets 0 in the Err bit and 0 in the Error register in the
Set Device Bits FIS. Then, it sends the Set Device Bits FIS to the host.
5) For the data transfer of the WRITE FP DMA QUEUED command, if the
DMA Setup Auto Activate function is disabled, the device sends to the host
the DMA Setup FIS with the settings of TAG = #, D bit = 0, A bit = 0, and I
bit = 0, and it sends the DMA Active FIS before it receives the Data FIS from
the host. (The Data FIS is transferred in units of up to 8 KB, with the actual
length of the Data FIS varying depending on the host).
6) If the DMA Setup AutoActivate function is enabled, the device sends to the
host the DMA Setup FIS with the settings of TAG = #, D bit = 0, A bit = 1,
and I bit = 0, and it then receives the Data FIS from the host (in units of 8
KB, 16 sectors).
7) When the write data transfer requested by the command is completed and the
command is completed normally, the bit in the SActive field in the SetDB
FIS corresponding to the tag number of the completed command is set by the
device, and the device sets 0 in the Err bit and 0 in the Error register in the
Set Device Bits FIS. Then, it sends the Set Device Bits FIS to the host. (The
DMA Setup AutoActivate function can be enabled and disabled by the SET
FEATURES command. The function is disabled by default.)
Summary of Contents for MHY2040BH
Page 4: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 19: ...Contents C141 E262 xv Glossary GL 1 Acronyms and Abbreviations AB 1 Index IN 1 ...
Page 24: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 266: ...This page is intentionally left blank ...
Page 288: ...This page is intentionally left blank ...
Page 304: ...This page is intentionally left blank ...
Page 308: ...This page is intentionally left blank ...
Page 310: ...This page is intentionally left blank ...
Page 318: ...This page is intentionally left blank ...
Page 320: ......
Page 321: ......
Page 322: ......