5.3 Host Commands
C141-E262
5-69
Table 5.21 Selective self-test log data structure
Byte(hex) Item
00, 01
Data Structure Revision Number
02 to 09
Starting LBA
0A to 11
Test Span 1
Ending LBA
12 to 19
Starting LBA
1A to 21
Test Span 2
Ending LBA
22 to 29
Starting LBA
2A to 31
Test Span 3
Ending LBA
32 to 39
Starting LBA
3A to 41
Test Span 4
Ending LBA
42 to 49
Starting LBA
4A to 51
Test Span 5
Ending LBA
52 to 151
Reserved
152 to 1EB
Vender Unique
1EC to 1F3
Current LBA under test
1F4 to 1F5
Current Span under test
1F6 to 1F7
Feature Flags
1F8
Offline Execution Flag
1F9
Selective Offline Scan Number
1FA, 1FB
Vender Unique
Reserved
1FC, 1FD
Selective Self-test pending time [min]
1FE, 1FF
Checksum
•
Test Span
Selective self-test log provides for the definition of up to five test spans. If the
starting and ending LBA values for a test span are both zero, a test span is not
defined and not tested.
•
Current LBA under test
As the self-test progress, the device shall modify this value to contain the LBA
currently being tested.
Summary of Contents for MHY2040BH
Page 4: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 19: ...Contents C141 E262 xv Glossary GL 1 Acronyms and Abbreviations AB 1 Index IN 1 ...
Page 24: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 266: ...This page is intentionally left blank ...
Page 288: ...This page is intentionally left blank ...
Page 304: ...This page is intentionally left blank ...
Page 308: ...This page is intentionally left blank ...
Page 310: ...This page is intentionally left blank ...
Page 318: ...This page is intentionally left blank ...
Page 320: ......
Page 321: ......
Page 322: ......