3.2 Mounting
(4) Ambient temperature
The temperature conditions for a disk drive mounted in a cabinet refer to the
ambient temperature at a point 3 cm from the disk drive. The ambient
temperature must satisfy the temperature conditions described in Section 1.4, and
the airflow must be considered to prevent the DE surface cover temperature from
exceeding 60
°
C.
Provide air circulation in the cabinet such that the PCA side, in particular,
receives sufficient cooling. To check the cooling efficiency, measure the surface
cover temperatures of the DE. Regardless of the ambient temperature, this
surface cover temperature must meet the standards listed in Table 3.1. Figure 3.4
shows the temperature measurement point.
1
Figure 3.4 Surface cover temperature measurement points
Table 3.1 Surface temperature measurement points and standard values
No. Measurement
point
Temperature
1
DE cover
60 °C max
C141-E244
3-5
Summary of Contents for MHV2160BT
Page 1: ...C141 E244 01EN MHV2200BT MHV2160BT DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 72: ...This page is intentionally left blank ...
Page 252: ...This page is intentionally left blank ...
Page 274: ...This page is intentionally left blank ...
Page 278: ...This page is intentionally left blank ...
Page 280: ...This page is intentionally left blank ...
Page 288: ...This page is intentionally left blank ...
Page 290: ...This page is intentionally left blank ...
Page 291: ......
Page 292: ......