MB15E07SL
6
■
ELECTRICAL CHARACTERISTICS
(V
CC
= 2.4 to 3.6 V, Ta = –40 to +85
°
C)
*1 : Conditions; fosc = 12 MHz, Ta = +25
°
C, in locking state.
*2 : V
CC
= V
P
= 3.0 V, fosc = 12.8 MHz, Ta = +25
°
C, in power saving mode
Parameter
Symbol
Condition
Value
Unit
Min
Typ
Max
Power supply current*
1
I
CC
*1
fin = 2500 MHz, V
CC
= V
P
= 2.7 V
(V
CC
= V
P
= 3.0 V)
–
3.5
(4.0)
–
mA
Power saving current
I
PS
ZC = “H” or open
–
0.1
*2
10
µ
A
Operating frequency
fin
f
IN
–
700
–
2500
MHz
OSC
IN
OSC
IN
–
3
–
40
MHz
Input sensitivity
fin
*3
Pfin
50
Ω
system
(Refer to the measurement
circuit.)
–15
–
+2
dBm
OSC
IN
*3
V
OSC
–
0.5
–
V
CC
Vp-p
“H” level input voltage
Data,
Clock,
LE, PS,
ZC
V
IH
–
V
CC
×
0.7
–
–
V
“L” level input voltage
V
IL
–
–
–
V
CC
×
0.3
“H” level input current
Data,
Clock,
LE, PS
I
IH
*4
–
–1.0
–
+1.0
µ
A
“L” level input current
I
IL
*4
–
–1.0
–
+1.0
“H” level input current
OSC
IN
I
IH
–
0
–
+100
µ
A
“L” level input current
I
IL
*4
–
–100
–
0
“H” level input current
ZC
I
IH
*4
–
–1.0
–
+1.0
µ
A
“L” level input current
I
IL
*4
Pull up input
–100
–
0
“L” level output voltage
φφφφ
P
V
OL
Open drain output
–
–
0.4
V
“H” level output voltage
φφφφ
R,
LD/fout
V
OH
V
CC
= V
P
= 3.0 V, I
OH
= –1 mA
V
CC
– 0.4
–
–
V
“L” level output voltage
V
OL
V
CC
= V
P
= 3.0 V, I
OL
= 1 mA
–
–
0.4
“H” level output voltage
Do
V
DOH
V
CC
= V
P
= 3.0 V, I
DOH
= –0.5 mA V
P
– 0.4
–
–
V
“L” level output voltage
V
DOL
V
CC
= V
P
= 3.0 V, I
DOL
= 0.5 mA
–
–
0.4
High impedance cutoff
current
Do
I
OFF
V
CC
= V
P
= 3.0 V,
V
OFF
= 0.5 V to V
P
– 0.5 V
–
–
2.5
nA
“L” level output current
φφφφ
P
I
OL
Open drain output
1.0
–
–
mA
“H” level output current
φφφφ
R,
LD/fout
I
OH
–
–
–
–1.0
mA
“L” level output current
I
OL
–
1.0
–
–
“H” level output current
Do
I
DOH
*4
V
CC
= 3 V,
V
P
= 3 V,
V
DO
= V
P
/2
Ta = +25
°
C
CS bit = “H”
–
–6.0
–
mA
CS bit = “L”
–
–1.5
–
“L” level output current
I
DOL
CS bit = “H”
–
6.0
–
CS bit = “L”
–
1.5
–
Charge pump current
rate
I
DOL
/I
DOH
I
DOMT
*5
V
DO
= V
P
/2
–
3
–
%
vs V
DO
I
DOVD
*6
0.5 V
≤
V
DO
≤
V
P
– 0.5 V
–
10
–
%
vs Ta
I
DOTA
*7
– 40
°
C
≤
Ta
≤
+85
°
C
–
10
–
%