C141-E134-01EN
vii
Task
Alert message
Page
Mounting Installation
protection fuse of the terminating resistor power supplier may
be blown or the cable may be burnt if overcurrent protection is
not provided.
When the recommended parts listed in Table 4.2 are used,
inserting the cables in the wrong direction can be prevented.
2. To connect SCSI devices, be careful of the connection position
of the cable. Check that the SCSI device with the terminating
resistor is the last device connected to the cable.
Data loss
When the SEND DIAGNOSTIC command terminates with the
CHECK CONDITION status, the INIT must collect the error
information using the REQUEST SENSE command. The RECEIVE
DIAGNOSTIC RESULTS command cannot read out the error
information detected in the self-diagnostics.
Caution
1. To avoid shocks, turn off the power before connecting or
disconnecting a cable, connector, or plug.
2. To avoid injury, do not touch the mechanical assembly during
disk drive operation.
3. Do not use solvents to clean the disk drive.
Caution
1. Always ground yourself with a wrist strap connected to ground
before handling. ESD (Electrostatics Discharge) may cause
the damage to the device.
2. To prevent electrical damage to the disk drive, turn the power
off before connecting or disconnecting a cable, connector, or
plug.
3. Do not remove a PCA. This operation is required to prevent
unexpected or unpredictable operation.
4. Do not use a conductive cleaner to clean a disk drive assembly.
5. Ribbon cables are marked with a colored line. Connect the
ribbon cable to a cable connector with the colored wire
connected to pin 1.
Damage
Never open the disk enclosure in the field. Opening the disk
enclosure in the field may cause an irreparable fault.
Data loss
Save data stored on the disk drive before requesting repair. Fujitsu
does not assume responsibility if data is destroyed during servicing
or repair.
6-4
6-5
6-6
6-6
6-15
6-7
Summary of Contents for MAM3184MC
Page 1: ...C141 E134 01EN MAM3367MC MP SERIES MAM3184MC MP SERIES DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 18: ...This page is intentionally left blank ...
Page 28: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 66: ...C141 E134 01EN 4 14 Figure 4 17 External operator panel connector CN2 ...
Page 124: ...8 8 C141 E134 01EN Figure 8 3 Block diagram of read write circuit ...
Page 130: ...This page is intentionally left blank ...
Page 134: ...This page is intentionally left blank ...
Page 140: ...This page is intentionally left blank ...
Page 148: ...This page is intentionally left blank ...
Page 150: ...This page is intentionally left blank ...
Page 151: ......
Page 152: ......