En-8

OPERATION

To Stop Operation

Press the START/STOP button.

The OPERATION indicator lamp (green) will go out.

Mode Operation

AUTO (in COOLING model):

 

 

  When AUTO (automatic changeover) operation 

fi

 rst selected, the fan will operate at very low speed for about a few 

minutes, during which time the indoor unit detects the room conditions and selects the proper mode.

 

  Room temperature is higher than the de

fi

 ned temperature in temperature 

setting 

 Cooling mode or dry mode 

 

  Room temperature is close to or lower than the defined temperature in 

temperature setting 

 Monitor operation

 

  When the indoor unit has adjusted your room’s temperature to near the temperature setting, it will begin monitor 

operation. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently 
changes, the indoor unit will once again select the appropriate operation (cooling) to adjust the temperature to the value 
set in the temperature setting.

 

  If the mode automatically selected by the unit is not what you wish, select one of the mode operation (COOL, DRY, FAN).

AUTO [in HEAT & COOL (Reverse Cycle) model]:

 

 

  When AUTO (automatic changeover) is selected, the air conditioner selects the appropriate operation mode (cooling or 

heating) according to your room’s present temperature.

 

 When AUTO operation 

fi

 rst selected, the fan will operate at low speed for about a few minute, during which time the 

indoor unit detects the room conditions and selects the proper operation mode.

 

  Room temperature is higher than the de

fi

 ned temperature in temperature 

setting 

 Cooling mode or dry mode

 

  Room temperature is close to the defined temperature in temperature 

setting 

 Determined by outdoor temperature

 

  Room temperature is lower than the defined temperature in temperature 

setting 

 Heating mode

 

  When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor 

operation. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently 
changes, the air conditioner will once again select the appropriate operation (heating, cooling) to adjust the temperature 
to the value set in the thermostat.

 

  If the mode automatically selected by the unit is not what you wish, select one of the mode operation (HEAT, COOL, DRY, FAN).

Cooling or Dry mode

De

fi

 ned 

temperature in 
temperature 
setting 

Heating mode

Determined by 
outdoor temperature 

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). 

During heating mode:

Set the thermostat to a temperature 
setting that is higher than the current room 
temperature. The heating mode will not 
operate if the thermostat is set lower than 
the actual room temperature.

During cooling/dry mode:

Set the thermostat to a temperature 
setting that is lower than the current room 
temperature. The cooling and dry modes 
will not operate if the thermostat is set 
higher than the actual room temperature (in 
cooling mode, the fan alone will operate).

During fan mode:

You cannot use the unit to heat and cool 
your room.

HEAT*:

 

  Use to warm your room.

 

  When heating mode is selected, the air conditioner will operate at very 

low fan speed for about 3 to 5 minutes, after which it will switch to the 
selected fan setting. This period of time is provided to allow the indoor unit 
to warm up before beginning full operation.

 

  When the room temperature is very low, frost may form on the outside 

unit, and its performance may be reduced. In order to remove such frost, 
the unit will automatically enter the defrost cycle from time to time. During 
automatic defrosting operation, the OPERATION indicator lamp will 

fl

 ash, 

and the heat operation will be interrupted.

 

  After the start of heating operation, it takes some time before the room 

gets warmer.

COOL:

 

  Use to cool your room.

DRY:

 

  Use for gently cooling while dehumidifying your room.

 

  You cannot heat the room during dry mode.

 

  During dry mode, the unit will operate at low speed; in order to adjust 

room humidity, the indoor unit’s fan may stop from time to time. Also, the 
fan may operate at very low speed when adjusting room humidity.

 

  The fan speed cannot be changed manually when dry mode has been selected.

FAN:

 

 

Use to circulate the air throughout your room.

De

fi

 ned 

temperature in 
temperature 
setting

Monitor operation 

Cooling mode 
or Dry mode

OM 01_9374379736-02_en.indd   8

OM 01_9374379736-02_en.indd   8

2/24/2559 BE   20:16

2/24/2559 BE   20:16

Summary of Contents for General ABG30UIA-LR

Page 1: ...GEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA ХРАНИТЕ РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ BU KILAVUZU İLERİDE BAŞVURMAK ÜZERE SAKLAYIN Português EλληvIkά Italiano Español Français Deutsch English Русский Tür...

Page 2: ...k of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable ga...

Page 3: ...he desired temperature Afterwards the unit automatically switches to a low power setting for economic and comfortable operation ECONOMY OPERATION When ECONOMY operation mode is operated the room temperature will be little higher than the set temp under cooling mode and lower than set temp under heating mode Therefore the ECONOMY mode is able to save more energy than other normal mode OMNI DIRECTIO...

Page 4: ...button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling operation starts by any chance press the START STOP button to stop the operation Please press the button at Filter Reset 3 Remote control signal receiver...

Page 5: ...ly If this button is pressed during normal operation the unit will switch to test run mode and the indoor unit s OPERATION indicator lamp and TIMER indicator lamp will begin to flash simultaneously To stop the test run press the START STOP button to stop the air conditioner F Signal transmitter G Temperature SET indicator H Operating mode indicator I SLEEP indicator J Transmit indicator K Fan spee...

Page 6: ...hildren from accidentally swallowing the batteries CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Exhausted batteries must be removed immediately and be disposed according to the local laws and regulations of you...

Page 7: ...peed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting the fan speed becom...

Page 8: ...ooling to adjust the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation HEAT COOL DRY FAN Cooling or Dry mode Defined temperature in temperature setting Heating mode Determined by outdoor temperature Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle During heating mo...

Page 9: ... is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light 2 Set the desired times for OFF timer and ON timer Se...

Page 10: ... minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During heating operation When the SLEEP timer is s...

Page 11: ...remote controller Use the SET buttons after the indoor unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 Types of Airflow Direction Setting 1 2 3 During cooling dry modes 1 2 3 4 5 During heating mode The remote cont...

Page 12: ...eeds To select up down swing operation ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green will go out Normal operation begins About ECONOMY Operation A...

Page 13: ...us tom code other than custom code A reset the custom code after replacing the batteries If you do not know the air conditioner custom code setting try each of the custom codes until you find the code which operates the air conditioner Use the following steps to select the custom code of the remote controller Note that the air conditioner cannot receive a signal if the air conditioner has not been...

Page 14: ...ights on when it is time to clean the air filters After turning the power on press the MANUAL AUTO button for 2 seconds or less on the indoor unit CLEANING AND CARE CAUTION When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized ser...

Page 15: ... tobacco etc which have been taken into the air conditioner Mist or steam are emitted During cooling or dry operation a thin mist may be seen emit ted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner result ing in condensation and misting During heating operation the outdoor unit s fan may stop and steam may be seen rising from the u...

Page 16: ...his air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recircu lating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high during use of the heating ...

Page 17: ...r can be added up to the maximum of 2 remote controllers Either remote controller can control the air conditioner However the timer functions cannot be used at the secondary unit Group Control 1 remote controller can control up to 16 air conditioners All of the air conditioners will be operated with the same settings The wired remote controller option is required to use the following function Duri...

Reviews: