EMA-MB91F467S-LS-176M07
Chapter
3: Switches and Jumpers
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 16 -
3.4 Port 17 Jumpers (APIX AIC Link)
If EMA-MB91FV460B-001 is used together with EMA-MB91F467S-LS-176M07 set J200-
J205 to 2-3 and the following mentioned restrictions will not apply!
When using EMA-MB91V460A-002B/-80/003 with the EMA-MB91V460A-300 extension
board for APIX emulation, it is possible to route the signals from the APIX Automotive
Interconnection Link on EMA-MB91V460A-300 to the appropriate pins of the EMA-
MB91F467S-LS-176M07.
Due to wrong pin connections (P17_7 is used as TCLKI on final MB91F467S instead of
P17_4) only the Use Cases where one of the data bits acts as the clock signal are
supported.
Please note: The APIX Automotive Interconnection Link 0 signals of EMA-MB91V460A-300
are routed to APIX Automotive Interconnection Link 1 of EMA-MB91F467S-LS-176M07
3.4.1 P17 / AIC Link function
Jumper U100 pin
P 1-2
[AIC Link used]
P 2-3
[P17 function]
P 3-4
[AIC Link used]
J200 87
1
J801_66 (RCK1)
P17_0 P17_0
pulldown
J201 86
J801_69
(RDA10) P17_1 P17_1
pulldown
J202 85
J801_70
(RDA11) P17_2 P17_2
pulldown
J203 83²
J801_67
(TCKI1)
P17_4 P17_4
pulldown
J204 82
J801_68
(TDA10)
P17_5 P17_5
pulldown
J205 81
J801_65
(TDA11)
P17_6 P17_6
pulldown
Default: all 2-3
1
Signal available, but corresponding Use Case not supported due to wrong pin assignment of TCLKI1 signal
² TCLKI1 signal available on this pin (P17_4 instead of P17_7)
Please refer also to the User Guide of EMA-MB91V460A-300 for the necessary settings on
that board.