background image

D3141 (RX600 S6) 

Technical Manual

39

Features

PCI interrupt assignment

The BIOS assigns the PCI interrupts automatically. Further settings are not 
possible. 

CPU - Memory board - PCI slot assignment 

I

Legacy I/O devices i.e. video cards are only supported on slots #1, 2, 3, 
4 or 10 

C

Slot 8

PCI Express 2.0 (x4), 3/4 length, x8 connector

no

D

Slot 7

PCI Express 2.0 (x8), 3/4 length, x8 connector 

yes

E

Slot 6

PCI Express 2.0 (x8), 3/4 length, x8 connector

yes

F

Slot 5

PCI Express 2.0 (x16), 3/4 length, x16 connector no

G

Slot 4

PCI Express 2.0 (x4), 1/2 length, x8 connector

no

H

Slot 3

PCI Express 2.0 (x4), 1/2 length, x8 connector

no

I

Slot 2

PCI Express 2.0 (x8), 3/4 length, x8 connector 

no

J

Slot 1

PCI Express 2.0 (x8), 3/4 length, x8 connector

no

K

I/O riser

PCI Express 1.0 (x1), PCIe type connector

no

L

SAS ctrl. PCI Express 2.0 (x8), x8 connector

no

CPU

Mem. board PCI slot

Remarks

1

1 & 2

1, 2, 3, 4, 10

2

3 & 4

1, 2, 3, 4, 10

3

5 & 6

5 - 9

CPU 3 must be installed to support 
PCI slots 5 - 9

4

7  &  8

5  -  9

Pos. PCIe slot Description

Hot-plug

Summary of Contents for D3141

Page 1: ...Technical Manual English System Board D3141 for PRIMERGY RX600 S6 Technical Manual July 2011 ...

Page 2: ...entation mbH 2011 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 11998 001 fm Copyright 2011 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes...

Page 3: ...these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The cust...

Page 4: ... notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain ...

Page 5: ...nical Manual 5 Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include CSS Customer Self Service Replacing the lithium battery ...

Page 6: ...6 Technical Manual D3141 RX600 S6 cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 11998 001 fm ...

Page 7: ... 21 3 2 1 Fitting rules 23 3 2 2 Memory configuration modes 24 3 2 3 Memory board configuration table 36 3 3 PCIe slots 38 3 4 Screen resolutions 40 3 5 Temperature and system monitoring 40 3 6 Connectors jumpers and indicators 42 3 6 1 Onboard connectors 42 3 6 2 Onboard jumpers 44 3 6 3 Onboard indicators 46 3 6 4 External connectors and indicators 48 3 6 5 Connectors and indicators on the I O r...

Page 8: ...Technical Manual D3141 RX600 S6 Contents cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 11999 001 fm ...

Page 9: ...ilable in PDF format on the ServerView Suite DVD 2 The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server The ServerView Suite Glossary can also be found on the ServerView Suite DVD 2 1 1 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and t...

Page 10: ...10 Technical Manual D3141 RX600 S6 Introduction cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 12000 001 fm ...

Page 11: ...d staff Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original pa...

Page 12: ...s to comply with EN 50173 and EN 50174 1 2 standards or ISO IEC 11801 standard respectively The minimum requirement is a Category 5 shielded cable for 10 100 Ethernet or Category 5e for Gigabit Ethernet Never connect or disconnect data transmission lines during a thunderstorm risk of lightning hazard Batteries V CAUTION Incorrect replacement of batteries may lead to a risk of explosion The batteri...

Page 13: ...always discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conduction p...

Page 14: ...without damaging components or conductors on the board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects screw drivers for leverage Do not damage or modify internal cables or devices Doing so may cause a device...

Page 15: ...ly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumable...

Page 16: ...nd consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste...

Page 17: ... with 4 GB 8 GB 16 GB and 32 GB capacity Up to 2048 GB memory with availability of 32 GB memory modules Minimum 8 GB 2 memory modules Maximum 32 Gbit s band width DDR3 Hardware memory scrubbing Single Device Data Correction SDDC function Chipkill Memory mirroring function Optional hot spare memory function Chipset devices on the system board Intel E7500 chipset 2x Intel Memory Controller Hub MCH I...

Page 18: ...1x PCI Express 1 0 x1 dedicated for I O riser board 1x PCI Express 2 0 x8 dedicated for SAS controller card Integrated Remote Management Controller iRMC S2 on I O riser The following features are integrated into iRMC S2 Server class Super I O SIO Remote KVMS Baseboard Management Controller BMC including the following functionality 250MHz 32 bit ARM9 processor IPMI 2 0 6x I2 C SMBus Two 10 100 Ethe...

Page 19: ...0BASE T 802 3 802 3u and 802 3ab applications Serializer Deserializer SerDes to support 1000BASE SX LX optical fiber and gigabit backplane applications SGMII for external PHY or SFP module Management of MAC and PHY Ethernet layer functions Management of PCI Express packet traffic across its transaction link and physical logical layers External SPI 4 wire serial interface to Flash EEPROM devices up...

Page 20: ...Module option The system board can be equipped with a Trusted Platform Module TPM by the manufacturer or by an add on kit This module enables programs from third party manufacturers to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated via the BIOS system for more information refer to the System Board D3141 BIOS Setup Utility for PRIMERGY RX600...

Page 21: ...048 GB ECC with memory scrubbing and the single device data correction SDDC function are standard There is no support for non ECC DIMMs Although there is an assignment between memory boards and CPUs see table on page 39 every CPU can access the memory installed in memory boards of all other CPUs The following figure shows the DIMM slot assignment of the memory riser board Figure 2 DIMM slot assign...

Page 22: ...lers so called Mboxes Each memory board comes with two memory buffers on board so called BOBs Each BOB controls two memory channels e g A B or C D For performance reasons two channels of different BOBs are used in parallel to access the DIMMs The DIMMs that are locked together this way as pairs are called lockstep pairs FNPSZ NPEVMFT T FNPSZ NPEVMFT T FNPSZ DPOUSM CPY FNPSZ DPOUSM CPY 0 PDLTUFQ QB...

Page 23: ...ep pairs see figure 3 on page 22 Both DIMMs of a pair must have identical values I This is a general rule Therefore memory boards must be fitted with DIMMs as follows 1 Start with DIMM slots 1B and 1D minimum per memory riser board 2 Now fill DIMM slots 1A and 1C 3 Continue with DIMM slots 2B and 2D 4 Finally fill DIMM slots 2A and 2C The fitting rules are also illustrated on the sticker on every ...

Page 24: ... BIOS of the server See the System Board D3141 BIOS Setup Utility for PRIMERGY RX600 S6 manual for detailed information Spare mode In spare mode one pair of DIMMs will be spare for the other pairs The spare DIMMs must have the same capacity or higher than the other DIMMs DIMM sparing only relates to BOBs There is no sparing over memory boards or CPUs Figure 5 Absolute minimum configuration in Spar...

Page 25: ...ain 4 DIMMs have to be added Figure 7 Second maximum upgrade in Spare Mode for 2 CPUs and 2 memory boards FNPSZ T CPY 4MPU 0 0 CPY CPY 4MPU 0 0 CPY 4QBSF T 4QBSF T FNQUZ FN PSZ CPBSE 16 16 16 NJO DPOGJH TU BEEJUJPO TQBSF FNPSZ T CPY 4MPU 0 0 CPY CPY 4MPU 0 0 CPY 4QBSF T 4QBSF T FN PSZ CPBSE 16 16 16 NJO DPOGJH TU BEEJUJPO OE BEEJUJPO TQBSF ...

Page 26: ... data are distributed over the Mboxes of each CPU see figure 8 on page 27 Therefore this type is called Intra Socket Interleaving 4 way interleaving mode also called Inter Socket Interleaving This type requires 2 memory boards per CPU and is possible with 2 or 4 CPUs The data are distributed over the Mboxes of two CPUs see figure 9 on page 28 Therefore this type is called Inter Socket Interleaving...

Page 27: ...o be added Figure 8 Upgrade configuration for 2 CPUs and 2 memory boards I The same upgrade rules have to be applied for 2 CPUs and 4 memory boards for 3 CPUs and 6 memory boards and for 4 CPUs and 8 memory boards 16 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY CPY FNPSZ CPBSE OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO BUB BSF EJTUSJCVUFE PWFS UIF UXP CPYFT PG 16 ...

Page 28: ...Socket with 2 CPUs and 4 memory boards For one upgrade step minimum 8 DIMMs one color have to be added Figure 9 Upgrade configuration for 2 CPUs and 4 memory boards I The same upgrade rules have to be applied for configurations with 4 CPUs 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO FN PSZ CPBSE 16 BUB BSF EJTUSJCVUFE PWFS GPVS C...

Page 29: ...ne color have to be added Figure 10 Upgrade configuration for 4 CPUs and 8 memory boards I This mode is only possible with 4 CPUs FN PSZ CPBSE 16 FNPSZ T BUB BSF EJTUSJCVUFE PWFS FJHIU CPYFT OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO 16 16 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 16 16 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 ...

Page 30: ...ll be mirrored from one Mbox to the other Mbox within the same CPU see figure 11 on page 31 Intrasocket Mirroring is possible for all CPU configurations 2 3 or 4 I This mode requires 2 memory boards per CPU 2 4 6 or 8 total All DIMMs must be identical same capacity and technology Intersocket Mirroring Memory will be mirrored from one Mbox to an Mbox on another CPU home agent to mirror agent see fi...

Page 31: ...ry Boards For one upgrade step minimum 4 DIMMs one color have to be added Figure 11 Upgrade configuration for 2 CPUs and 2 memory boards 16 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY CPY FNPSZ CPBSE OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO BUB BSF NJSSPSFE GSPN CPY UP CPY PO TBNF 16 ...

Page 32: ...ds For one upgrade step minimum 8 DIMMs one color have to be added Figure 12 Upgrade configuration for 2 CPUs and 4 memory boards I The same upgrade rules have to be applied for configurations with 3 or 4 CPUs 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO FN PSZ CPBSE 16 BUB BSF NJSSPSFE GSPN CPY UP CPY PO TBNF 16 BUB BSF NJSSPSFE ...

Page 33: ...JO DPOGJH SE BEEJUJPO TU BEEJUJPO FN PSZ CPBSE 16 16 16 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 BUB BSF NJSSPSFE GSPN POF CPY UP TBNF CPY PO PUIFS 16 BUB BSF NJSSPSFE GSPN POF CPY UP TBNF CPY PO PUIFS 16 CPY Y 4 4MMP PU U 0 0 0 0 0 0 PNF HFOU CPY Y 4 4MMP PU U 0 0 0 0 PNF HFOU CPY Y 4 4MMP PU U 0 0 0 0 JSSPS HFOU CPY Y 4 4MMP PU U 0 0 0 0 JSSPS HFOU CPY Y 4 4MMP PU U 0 0 0 0 PNF HFOU C...

Page 34: ...n the other Mbox of the same CPU Hemisphere mode is possible with 2 3 or 4 CPUs I All DIMMs must be identical same capacity and technology A memory board must have a capacity of 8 16 32 64 or 128 GB The configuration of the memory boards per CPU must be the same Hemisphere Mode with 2 CPUs and 2 Memory Boards Figure 14 Minimum configuration for 2 CPUs and 2 memory boards 16 FNPSZ T 16 CPY 4MPU 0 0...

Page 35: ...be configured the same way Since channel 1 is equipped with 16 DIMMs after the first upgrade step channel 2 also has to be equipped with 16 DIMMs I The same upgrade rules have to be applied for configurations with 3 and 4 CPUs 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 FN PSZ CPBSE 16 OE BEEJUJPO TU BEEJUJPO NJO DPOGJH CPY Y 4 4MMP PU U 0 0 0 0 0 0 PXFS FNJTQIFSF CPY Y 4 4MM...

Page 36: ...2 way configuration 3 way configuration Memory Mode CPU 1 CPU 2 CPU 3 CPU 4 No of Mem boards None Lock step Spare Inter leaving 2 way Mirror Intra socket Memory Board Slot No 1 2 3 4 5 6 7 8 2 X X 1st 2nd 3 X X 1st 3rd 2nd 4 X X 1st 3rd 2nd 4th 4 X X 1st 2nd 3rd 4th Memory Mode CPU 1 CPU 2 CPU 3 CPU 4 No of Mem boards None Lock step Spare Inter leaving 2 way Mirror Intra socket Memory Board Slot N...

Page 37: ...k step Spare Inter leaving 2 way Mirror Intra socket Memory Board Slot No 1 2 3 4 5 6 7 8 2 X X 1st 2nd 3 X X 1st 3rd 2nd 4 X X 1st 3rd 2nd 4th 4 X X 1st 2nd 3rd 4th 5 X X 1st 5th 3rd 2nd 4th 6 X X 1st 5th 3rd 2nd 6th 4th 6 X X 1st 2nd 5th 6th 3rd 4th 7 X X 1st 5th 3rd 7th 2nd 6th 4th 8 X X X X 1st 2nd 5th 6th 3rd 4th 7th 8th ...

Page 38: ... Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 12002 001 fm 3 3 PCIe slots Figure 16 PCIe slots on system board D3141 Pos PCIe slot Description Hot plug A Slot 10 PCI Express 1 0 x4 1 2 length x8 connector no B Slot 9 PCI Express 1 0 x4 1 2 length x8 connector no K L F G H I J A B C D E ...

Page 39: ...CI Express 2 0 x8 3 4 length x8 connector yes F Slot 5 PCI Express 2 0 x16 3 4 length x16 connector no G Slot 4 PCI Express 2 0 x4 1 2 length x8 connector no H Slot 3 PCI Express 2 0 x4 1 2 length x8 connector no I Slot 2 PCI Express 2 0 x8 3 4 length x8 connector no J Slot 1 PCI Express 2 0 x8 3 4 length x8 connector no K I O riser PCI Express 1 0 x1 PCIe type connector no L SAS ctrl PCI Express ...

Page 40: ...fan speed Temperature and system monitoring is controlled by an onboard controller that supports the following functions Temperature monitoring Measuring of the processor temperature memory module and ambient temperature by way of a temperature sensor If the critical upper temperature value is reached the system will turn off immediately Fan monitoring The fans are monitored Fans that are blocked ...

Page 41: ...ppen all fans run at maximum speed to ensure the highest possible protection of the hardware Power monitoring When the voltage exceeds or falls below the warning levels an alert is issued and the system will start to throttle System Event Log SEL All monitored critical and warning events of the system board are signalized via the Global Error LED or CSS LED and recorded in the System Event Log The...

Page 42: ...im_app tim_local work PICHOL OBJ_DOKU 12002 001 fm 3 6 Connectors jumpers and indicators 3 6 1 Onboard connectors Figure 17 Connectors on system board D3141 Pos Connector Pos Connector A PCIe slots see figure B I O riser slot 1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 4 5 6 7 8 9 10 B C G F M P L M N M O L M H I J G E D 5 4 3 2 1 0 K A ...

Page 43: ...B ports 2x H HDD activity I TPM Trusted Platform Module J internal USB cable conn K Processor sockets see figure L Signal connectors to Front Panel Fan Board M Power connectors to Power Distribution Board N Signal connector to Power Distribution Board O Power connector to Power Distribution Board P Memory board slots see figure Pos Connector Pos Connector ...

Page 44: ... Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 12002 001 fm 3 6 2 Onboard jumpers Figure 18 Position of the jumpers on system board D3141 Pos Jumper A Clear CMOS J5C2 B Password Disable Clear J5C3 C Reserved J5C1 D BIOS Recovery J6D1 D C B A ...

Page 45: ...tings of Jumper Clear CMOS J5C2 Settings of Jumper Password Disable Clear J5C3 Settings of the reserved Jumper J5C1 Settings of Jumper BIOS Recovery J6D1 Clear CMOS Normal Default Disable Clear Protect Default Default setting Recover Normal Default ...

Page 46: ... tim_local work PICHOL OBJ_DOKU 12002 001 fm 3 6 3 Onboard indicators Figure 19 Indicators and indicate CSS button on system board D3141 The positions in the figure have the following meaning Pos Indicator A Hot swap status LEDs for PCIe slot 7 B Hot swap status LEDs for PCIe slot 6 1 2 3 4 1 2 3 4 5 6 7 8 9 10 F G H I A B D E C ...

Page 47: ...s been removed If the server has been powered off power plugs must be disconnected it is possible to indicate the faulty component by pressing the indicate CSS button C CSS LEDs for PCIe slots 1 10 D VRM PWRGD LED E Platform Reset LED F System ID LED G CSS LED for SAS controller card slot H Indicate CSS button I CSS LEDs for CPU 1 4 see figure Pos Indicator ...

Page 48: ...okumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 12002 001 fm 3 6 4 External connectors and indicators Figure 20 External connectors and indicators on system board D3141 Pos Indicator A System ID LED B System ID button C 2x USB connector B A C ID ...

Page 49: ...t controllers system LAN and an ARM9 controller management LAN These LAN controllers support transmission rates of 10 Mbit s 100 Mbit s and 1 Gbit s only system LAN They also support WoL functionality by means of Magic Packet Pos Indicator A 4x LAN connector LED description on page 50 B Global Error LED orange C Serial connector D Video connector VGA E CSS LED yellow F Management LAN connector LED...

Page 50: ...nagement interface iRMC S2 and is prepared for operation with the Remote Management Each LAN controller connector has two LEDs that indicate the transfer rate A and the state B of the connection Figure 22 LEDs of the LAN ports on the I O riser board Pos Function Description A LAN speed system LAN Steady yellow signal in the event of a LAN transfer rate of 1 Gbit s Steady green signal in the event ...

Page 51: ...hen LAN transfer takes place C LAN link transfer management LAN Steady green signal when a LAN connection exists Remains dark when no LAN connection exists Flashes green when LAN transfer takes place D LAN speed management LAN Steady green signal in the event of a LAN transfer rate of 100 Mbit s Remains dark in the event of a LAN transfer rate of 10 Mbit s Pos Function Description ...

Page 52: ...52 Technical Manual D3141 RX600 S6 Features cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 12002 001 fm ...

Page 53: ...nese market only the Fujitsu service partner can replace the lithium battery Do not throw lithium batteries into the trash can They must be disposed of in accordance with local regulations on special waste Make sure you insert the lithium battery the right way round the positive pole must be on the housing side Figure 23 Replacing the lithium battery boards removed for clarity Ê Press the metal cl...

Page 54: ...54 Technical Manual D3141 RX600 S6 Replacing the lithium battery cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 12003 001 fm ...

Reviews: