NAS maintenance
Fujitsu
55
EuP mode configuration (for compliance with legal
standby requirements)
The EU directive 2009/125/EC defines ecodesign requirements for energy-related products. In order
to comply with this directive, the EuP mode needs to be activated.
►
Activate EuP mode under
Control Panel - System Settings - Power
.
When EuP mode is enabled, the following settings will be affected so that the server maintains low
power consumption (less than 0.5W) when the server is powered off:
●
Wake on LAN: Disabled.
●
AC power resumption: The server will remain off after the power restores from an outage.
●
Schedule power on/ off/ restart settings: Disabled.
If EuP mode is deactivated, the power consumption of the server is greater than 0.5W when
switched off. EuP is disabled by default so that you can use the functions Wake on LAN, AC power
resumption, and power schedule settings properly.