En-7

9.  SETTINGS ON INSTALLATION

9.1.  Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can 
specify the air conditioner which the remote controller controls.

When two or more air conditioners are in the room and you wish to 

operate them separately, set the custom code (4 selections possible).

NOTES: If custom codes is different between the indoor unit and the 

remote controller, the indoor unit cannot receive a signal from 
the remote controller.

How to set the remote controller custom code

1.   Press 

 until only the clock is displayed on the remote 

controller display.

2.   Press and hold

 

 

for more than 

5 seconds.

The current custom code will be 
displayed (initially set to A).

3.  Press 

 to change the 

custom code between A↔B↔C↔D 

(

).

* Match the custom code on the display 
to the air conditioner custom code.

4.  Press 

 again.

The custom code will be set.  
The display  will return to the clock display.

•  To change the air conditioner custom code, contact an authorized 

service personnel (initially set to A).

•   If you do not press any buttons for 30 seconds after the custom 

code is displayed, the display returns to the clock display. In this 
case, repeat the setting from step 2.

•  Depending on the remote controller, the custom code may return 

to A when replacing the batteries. In this case, reset the custom 
code as necessary. If you do not know the air conditioner custom 

code, try each code until you find the code which operates the air 

conditioner.

10. CLEANING  AND  CARE

 

CAUTION

•  Before cleaning this product, be sure to turn it off and 

disconnect all the power supply. 

•  Before starting operation, make sure that the intake 

grille has been shut completely. Incomplete closing 
of the intake grille might have an effect on the proper 
working or performance of the air conditioner.

• 

If the filter cleaning involves high-place work, please 

consult the authorized service

 

personnel.

• 

Do not touch the aluminum fins of heat exchanger 

built-in the indoor unit to avoid personal injury when 
you  maintain the unit.

•  Do not expose the indoor unit to liquid insecticides or 

hair sprays.

•  Do not stand on slippery, uneven or unstable surfaces 

when you maintain the unit.

Intake grille

Air filters

Indoor unit body

Air cleaning filters

(Apple catechin filter, Ion deodorization filter)

The frequency of the cleaning is as shown in the following table.

What to do

Frequency

Cleaning indoor unit body

When you notice

Cleaning air filter

Every 2 weeks

Cleaning Ion deodorization filter

Every 3 months

Replacing Apple-catechin filter

(Model name: UTR-FA16)
Replacing Ion deodorization filter

(Model name: UTR-FA16-2)

Every 3 years

* The air cleaning filters are sold separately. When you replace them, 

please contact the store of purchase.

Cleaning indoor unit body

NOTES:

• 

Do not use water hotter than 40 °C.

•  Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

1.  Wipe the indoor unit body gently with a soft cloth moisten 

with warm water.

2.  Wipe the indoor unit body gently with a dry and soft cloth.

Cleaning air filter

1.  Open the intake grille until it snaps.

2. 

Remove the air filters.

Lift up the air filters' handle, disconnect the two lower tabs, and pull 

out.

Air Filter handle

Tabs (2 places)

3.  Remove the dust in either of the following ways.

•  Cleaning with vacuum cleaner.
•  Washing with mild detergent and warm water. After washing, dry the 

air filters thoroughly in shade.

4. 

Replace the air filters.

Align the sides of the air filter with the panel, and push in fully. 

Make sure to the two lower tabs are returned to their holes in the 
indoor unit properly.

5.  Close the intake grille. 

Press 4 places on the intake grille to close it completely.

NOTES: 

If dirt accumulates on the air filter, airflow will be reduced, 

operating  efficiency will lower, and the noise will increase.

9387858020_OM.indb   7

2/8/2019   1:53:16 PM

Summary of Contents for ASYG07KMTB

Page 1: ...montage mural Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di util...

Page 2: ...nsult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air ...

Page 3: ...rroundings of the outdoor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product...

Page 4: ...er to page 6 Activates the 10 C Heat operation 3 1 Indoor unit Remote controller signal receiver Horizontal airflow direction louvers For Manual Auto operation and Filter indicator reset Refer to page 11 Rating label Drain hose Indicator lamps 2 Front panel Air filter Intake grille 1 Air cleaning filter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation...

Page 5: ...Powerful operation Refer to page 6 Activates or deactivates the Powerful operation For Airflow settings Refer to page 5 Controls the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Sets the On...

Page 6: ... displayed as follows Timer Indicator on the remote controller display On Off timer Off On timer NOTES You can set the Program timer only within a span of 24 hours If you set the Sleep timer after setting the Program timer the Program timer is canceled 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode change...

Page 7: ...e Powerful operation When activated the indoor unit will emit 2 short beeps When deactivated the indoor unit will emit 1 short beep The Powerful operation will be turned off automatically in the following situations The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling Dry or Heating mode 20 minutes after the Powerful operation...

Page 8: ...ilter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Air filters Indoor unit ...

Page 9: ...dorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a horizontal position Inst...

Page 10: ...IONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard and indicator on the indoor unit will blink Restricted functions for wireless remote controller When using together ...

Page 11: ...n the heating apparatus or computers off or set the temperature lower Refer to page 5 Airflow is weak or stops Is the fan speed set to Quiet To change the fan speed refer to page 5 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the se...

Page 12: ...test run Restricted function Slow Slow In multi connection Standby mode Check the set operation mode of the indoor units 9 Manual Auto operation and Filter indicator reset You can operate the air conditioner with on the indoor unit Status Time to keep pressing Mode or operation In operation More than 3 seconds Stop Stopping 2 seconds or less Filter indicator reset More than 3 seconds and less than...

Reviews: