6.3.  Sleep timer 

The Sleep timer supports your comfortable sleep by moderating the air 
conditioner operation gradually.

1.  Press 

.

2.  Press 

(

)

 to set the time until the operation 

stops.

Each time you press the button, the time changes as follows:

9H

00M

7H

00M

5H

00M

3H

00M

2H

00M

1H

00M

0H

30M

hours

(30 min.)

NOTES:  If you do not press any buttons for 5 seconds, the remote 

controller display returns to the standby screen.

• 

The setting time is kept even if the Sleep timer finishes. To repeat 

the Sleep timer, press 

 while 

 is not shown on the 

remote controller display.

•  To deactivate the Sleep timer, press 

 while 

 is shown 

on the remote controller display. 
The indicator will disappear.

During the Sleep timer operation, the setting temperature changes as 

the following figure.

In Heating mode

Set 
temperature

Set time

1 hour

Set time

1 hour

1.5 hour

30 min.

1 °C 2 °C 3 °C 4 °C

2 °C

1 °C

In Cooling or Dry mode

After the set time has elapsed, the air conditioner operation turns off.

NOTES:  If you set the On timer or Off timer after setting the Sleep 

timer, the Sleep timer is canceled.

7.  ENERGY SAVING OPERATION

7.1.  Economy operation

It saves more electricity than other operation modes by changing the set 
temperature to a moderate setting.

)

)

Press 

 to activate/deactivate the Economy 

operation.

 ] indicator on the indoor unit will turn on.

Operation 

mode

Room temperature

Cooling/Dry

Few degrees higher than the set temperature

Heating

Few degrees lower than the set temperature

NOTES:

•  In the Cooling, Heating, or Dry mode, the maximum output of this 

operation is approximately 70 % of usual operation.

•  This operation cannot be performed during the temperature 

monitoring by the Auto mode.

8.  OTHER OPERATIONS

8.1.  Powerful operation

In the Powerful operation, the air conditioner will operate at maximum 

power and strong airflow to cool down or warm up the room quickly.

NOTES: In multi connection, this function cannot be used.

)

)

Press 

 to activate/deactivate the Powerful operation.

When activated, the indoor unit will emit 2 short beeps.

When deactivated, the indoor unit will emit 1 short beep.

The Powerful operation will be turned off automatically in the following 
situations:

•  The Powerful operation runs for a certain amount of time and the 

room temperature reaches the set temperature in the Cooling, Dry, 
or Heating mode.

•  20 minutes after the Powerful operation has started.

NOTES:

• 

The airflow direction and the fan speed are controlled automatically.

•  The Powerful operation cannot be performed simultaneously with 

Economy operation.

•  The Powerful operation overrides the following operations. If 

the following operations are set, they will start after the Powerful 

operation finishes.

 

- Outdoor Unit Low Noise operation

 

- Energy Saving program

•  If the wired remote controller (optional) is connected, this function is 

restricted.

8.2.  Outdoor Unit Low Noise operation

The Outdoor Unit Low Noise operation lowers noise from the outdoor 
unit. During this operation, the rotation number of the compressor 
decreases and the outdoor unit fan rotates slowly.

NOTES: In multi connection, this function cannot be used.

)

)

Press 

 to activate/deactivate the Outdoor Unit Low 

Noise operation.

While the Outdoor Unit Low Noise operation is activated, 

 

on the remote controller is displayed.
The setting is preserved even if the air conditioner is turned off.

NOTES: 

•  This operation cannot be performed simultaneously with the Fan 

mode, Dry mode, and Powerful operation.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

8.3.  10 °C Heat operation

10 °C Heat operation maintains the room temperature at 10 °C so as to 

prevent the room temperature to drop too low.

)

)

Press 

 to activate the 10 °C Heat operation.

The indoor unit will emit 1 short beep and [ 

 ] indicator on the 

indoor unit will turn on.

)

)

Press 

 to turn off the air conditioner. 

 ] indicator will turn off.

NOTES:

• 

During the 10 °C Heat operation, only 

 is valid.

•  When the room temperature is warm enough, this operation will not 

perform.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

9387858020_OM.indb   6

2/8/2019   1:53:15 PM

Summary of Contents for ASYG07KMTB

Page 1: ...montage mural Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di util...

Page 2: ...nsult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air ...

Page 3: ...rroundings of the outdoor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product...

Page 4: ...er to page 6 Activates the 10 C Heat operation 3 1 Indoor unit Remote controller signal receiver Horizontal airflow direction louvers For Manual Auto operation and Filter indicator reset Refer to page 11 Rating label Drain hose Indicator lamps 2 Front panel Air filter Intake grille 1 Air cleaning filter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation...

Page 5: ...Powerful operation Refer to page 6 Activates or deactivates the Powerful operation For Airflow settings Refer to page 5 Controls the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Sets the On...

Page 6: ... displayed as follows Timer Indicator on the remote controller display On Off timer Off On timer NOTES You can set the Program timer only within a span of 24 hours If you set the Sleep timer after setting the Program timer the Program timer is canceled 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode change...

Page 7: ...e Powerful operation When activated the indoor unit will emit 2 short beeps When deactivated the indoor unit will emit 1 short beep The Powerful operation will be turned off automatically in the following situations The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling Dry or Heating mode 20 minutes after the Powerful operation...

Page 8: ...ilter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Air filters Indoor unit ...

Page 9: ...dorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a horizontal position Inst...

Page 10: ...IONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard and indicator on the indoor unit will blink Restricted functions for wireless remote controller When using together ...

Page 11: ...n the heating apparatus or computers off or set the temperature lower Refer to page 5 Airflow is weak or stops Is the fan speed set to Quiet To change the fan speed refer to page 5 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the se...

Page 12: ...test run Restricted function Slow Slow In multi connection Standby mode Check the set operation mode of the indoor units 9 Manual Auto operation and Filter indicator reset You can operate the air conditioner with on the indoor unit Status Time to keep pressing Mode or operation In operation More than 3 seconds Stop Stopping 2 seconds or less Filter indicator reset More than 3 seconds and less than...

Reviews: