background image

En-10

● 

Operation can be done in the following different operating modes. 

 

Cooling mode and Dry mode 

 

Cooling mode and Fan mode 

 

Dry mode and Fan mode

● 

The operating mode (Heating mode or Cooling (Dry) mode) of the out-
door unit will be determined by the operating mode of the indoor unit 

that was operated first. If the indoor unit was started in the Fan mode, 

the operating mode of the outdoor unit will not be determined. 

  For example, if indoor unit (A) was started in the Fan mode and then 

indoor unit (B) was then operated in the Heating mode, indoor unit (A) 
would temporarily start operation in the Fan mode but when indoor 
unit (B) started operating in the Heating mode, [   ] indicator for indoor 

unit (A) would begin to flash (1 second on, 1 second off) and it would 

go into standby mode.  Indoor unit (B) would continue to operate in 
Heating mode.

13. TROUBLESHOOTING

 WARNING

In the following events, immediately stop operation of 
the air conditioner, and disconnect all the power supply 
by turning off the electrical breaker or disconnecting 
the power plug. Then consult your dealer or authorized 
service personnel.
As long as the unit is connected to the power supply, it 
is not insulated from the power supply even if the unit is 
turned off.
•  Unit smells of something burning or emits smoke
•  Water leaks from the unit

Does not operate at all.

 

Has there been a power outage?  
In this case, the unit restarts automatically after the power supply 
is resumed. (Refer to page 9.)

 

Has the circuit breaker been turned off?  

⇒ 

Turn on the circuit breaker.

 

Has a fuse blown out or the circuit breaker been tripped? 

⇒ 

Replace the fuse or reset the circuit breaker.

 

Is the timer operating? 

 To check or deactivate the timer setting, refer to page 5.

Poor cooling or heating performance.

 

Is the unit operating under the conditions except the permissible 
temperature range?  
In this case, the air conditioner may stop because of the automatic 
protection circuit working.

 

Is the 

air filter dirty?

 

 Clean the air filter. (Refer to 

page 7.

 

Is the intake grille or outlet port of indoor unit blocked? 

 Remove the obstructions.

 

Is the room temperature adjusted appropriately? 

 To change the temperature setting, refer to page 5.

 

Is a window or door left opened? 

 Close the window or the door.

 

Is the fan speed set to Quiet?  

 To change the fan speed, refer to page 5.

 

Has the Outdoor Unit Low Noise operation been set? 

 To stop the Outdoor Unit Low Noise operation, refer to page 6.

 

<In the Cooling mode> Is direct or strong sunlight shining into the 

room? 

 Close the curtains.

 

<In the Cooling mode> Are there other heating apparatus or com

-

puters operating, or too many people in the room?

 Turn the heating apparatus or computers off, or set the 

temperature lower. (Refer to page 5.)

Airflow is weak or stops.

 

Is the fan speed set to Quiet?  

⇒ 

To change the fan speed, refer to page 5.

 

<In the Heating mode> Have you just started the operation? 

 

In this case, the fan rotates at very low speed temporarily to warm 
up the internal parts of the unit.

 

<In the Heating mode> Is the room temperature higher than the 

set temperature?  
In this case, the outdoor unit stops and the indoor unit fan rotates 
at very low speed. 

 

<In the Heating mode> Is  [ 

 ] indicator blinking?  

In this case, the Automatic defrosting operation is working. The in-

door unit stops for maximum of 15 minutes. (Refer to 

page 9.)

 

<In the Dry mode> The indoor unit operates at low fan speed to 

adjust the room humidity, and may stop from time to time.

 

<In the Auto mode> While the monitoring operation, the fan 

rotates at very low speed.

Noise is heard.

 

Is the unit operating, or immediate after stopping operation? 

In this case, refrigerant flowing sound may be heard. It may be 

particularly noticeable for 2-3 minutes after starting operation.

 

Do you hear a slight squeaking sound during the operation?  
This sound is produced by the minute expansion and contraction 
of the front panel caused by temperature change.

 

<In the Heating mode> Do you hear a sizzling sound? 

 

This sound is produced by the Automatic defrosting operation. 
(Refer to page 9.)

Smell coming from the unit.

 

The air conditioner may absorb various smells generated from 
interior textile, furniture, or cigarette smoke. These smells may be 
emitted during the operation.

Mist or steam is emitted from the unit.

 

<In the Cooling or Dry mode> A thin mist may be generated by 

condensation formed with sudden cooling process.

 

<In the Heating mode> Is [ 

 ] indicator on the indoor unit blinking?  

In this case, steam may rise from the outdoor unit because of the 
Automatic defrosting operation.(Refer to page 9.)

Outdoor unit emits water.

 

<In the Heating mode> The outdoor unit may emit water gener

-

ated by the Automatic defrosting operation. (Refer to page 9.)

The unit operates differently from the remote controller setting.

 

Are the batteries in the remote controller exhausted? 

 Replace the batteries.

Operation is delayed after restart.

 

Has the power supply turned from Off to On suddenly?  
In this case,  the compressor will not operate for about 3 minutes 
to prevent a blowout of the fuse.

Immediately stop operation and turn off the electrical breaker in 
following cases. Then consult authorized service personnel.

•  The problem persists even if you perform these checks or 

diagnostics.

•  On the indoor unit, [   ] and [ 

 ] blink while [ 

 ] is blinking fast.

NOTES: For any troubleshooting related to the W-LAN control, refer 

to the setting manual for W-LAN adapter or the mobile app 
installed in your smartphone or tablet PC.

9387858020_OM.indb   10

2/8/2019   1:53:17 PM

Summary of Contents for ASYG07KMTB

Page 1: ...montage mural Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di util...

Page 2: ...nsult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air ...

Page 3: ...rroundings of the outdoor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product...

Page 4: ...er to page 6 Activates the 10 C Heat operation 3 1 Indoor unit Remote controller signal receiver Horizontal airflow direction louvers For Manual Auto operation and Filter indicator reset Refer to page 11 Rating label Drain hose Indicator lamps 2 Front panel Air filter Intake grille 1 Air cleaning filter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation...

Page 5: ...Powerful operation Refer to page 6 Activates or deactivates the Powerful operation For Airflow settings Refer to page 5 Controls the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Sets the On...

Page 6: ... displayed as follows Timer Indicator on the remote controller display On Off timer Off On timer NOTES You can set the Program timer only within a span of 24 hours If you set the Sleep timer after setting the Program timer the Program timer is canceled 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode change...

Page 7: ...e Powerful operation When activated the indoor unit will emit 2 short beeps When deactivated the indoor unit will emit 1 short beep The Powerful operation will be turned off automatically in the following situations The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling Dry or Heating mode 20 minutes after the Powerful operation...

Page 8: ...ilter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Air filters Indoor unit ...

Page 9: ...dorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a horizontal position Inst...

Page 10: ...IONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard and indicator on the indoor unit will blink Restricted functions for wireless remote controller When using together ...

Page 11: ...n the heating apparatus or computers off or set the temperature lower Refer to page 5 Airflow is weak or stops Is the fan speed set to Quiet To change the fan speed refer to page 5 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the se...

Page 12: ...test run Restricted function Slow Slow In multi connection Standby mode Check the set operation mode of the indoor units 9 Manual Auto operation and Filter indicator reset You can operate the air conditioner with on the indoor unit Status Time to keep pressing Mode or operation In operation More than 3 seconds Stop Stopping 2 seconds or less Filter indicator reset More than 3 seconds and less than...

Reviews: