background image

En-7

 

Details on Demand Response mode

DR mode

Description of operation in this mode

DR mode 1

Compressor off.

DR mode 2

Electrical energy consumption in 30 minutes:
50 % or less 

(compared with rated energy consumption)

DR mode 3

Electrical energy consumption in 30 minutes:
75 % or less

(compared with rated energy consumption)

NOTES:

•  During the DR mode, the cooling or heating performance may be 

reduced.

•  During the DR mode, only the following operations are valid.

 -

Turning off the operation by 

 -

Off timer operation

•  The Powerful operation is performed within the operable range of 

the DR mode.

•  During the DR mode, the Filter sign will not display.

•  Timer setting error indicator will be prioritized over the DR mode 

indicator.

If you have operational issues:

(1)  Contact your electricity supplier to check whether they are activating 

the DR mode.

(2)  Is the air conditioner under the Demand controlling?

Yes

Contact your electricity supplier.

No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to 

your warranty card.) 
or

• Visit our website (www.fujitsugeneral.com.au).

8.  OTHER OPERATION

8.1.  Powerful operation

In the Powerful operation, the air conditioner will operate at maximum 

power and strong airflow to cool down or warm up the room quickly.

 

)

Press 

 to activate/deactivate the Powerful operation.

When activated, the indoor unit will emit 2 short beeps.

When deactivated, the indoor unit will emit 1 short beep.

The Powerful operation will be turned off automatically in the following 

situations:

•  The Powerful operation runs for a certain amount of time and the 

room temperature reaches the set temperature in the Cooling, Dry, 

or Heating mode.

•  20 minutes after the Powerful operation has started.

NOTES:

• 

The airflow direction and the fan speed are controlled automatically.

•  The Powerful operation cannot be performed simultaneously with 

Economy operation.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

9.  SETTINGS ON INSTALLATION

9.1.  Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can 

specify the air conditioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to 

operate them separately, set the custom code (4 selections possible).

NOTE: 

If custom codes are different between the indoor unit and the 

remote controller, the indoor unit cannot receive a signal from 

the remote controller.

How to set the remote controller custom code

1. 

 Press 

 until the indicators on the remote controller turn 

off.

2. 

 Press  down 

 for more than 5 seconds.

The current custom code will be displayed (initially set to A).

3. 

Press 

 to change 

the custom code between  

A (

) ↔ B ( ) ↔ C (

/

) ↔D (

).

* Match the custom code on the display 

to the air conditioner custom code.

4. 

Press 

 again.

The custom code will be set.  

The display will return to the original 

display.

•  To change the air conditioner custom code, contact authorized 

service personnel (initially set to A).

•   If you do not press any buttons for 30 seconds after the custom 

code is displayed, the displayed custom code is set and the 

display returns to the original display.

•  Depending on the remote controller, the custom code may return 

to A when replacing the batteries. In this case, reset the custom 

code as necessary. If you do not know the air conditioner custom 

code, try each code until you find the code which operates the air 

conditioner.

10. CLEANING AND CARE

 

CAUTION

• 

Before cleaning this product, be sure to turn it off and 

disconnect all the power supply. 

•  Before starting operation, make sure that the intake 

grille has been shut completely. Incomplete closing 

of the intake grille might have an effect on the proper 

working or performance of the air conditioner.

• 

If the filter cleaning involves high-place work, consult 

the authorized service personnel.

• 

Do not touch the aluminum fins of heat exchanger 

built-in the indoor unit to avoid personal injury when 

you maintain the unit.

•  Do not expose the indoor unit to liquid insecticides or 

hair sprays.

•  Do not stand on slippery, uneven or unstable surfaces 

when you maintain the unit.

Intake grille

Air filter

Indoor unit body

The frequency of the cleaning is as shown in the following table.

What to do

Frequency

Cleaning indoor unit body

When you notice

Cleaning air filter

Every 2 weeks

Cleaning indoor unit body

NOTES:

•  Do not use water hotter than 40 °C.

•  Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

9333892030-02_OM_EN.indd   7

9333892030-02_OM_EN.indd   7

01/27/2022   08:35:06

01/27/2022   08:35:06

Summary of Contents for ASTH07KNCA

Page 1: ... Off timer 6 6 2 Program timer 6 6 3 Sleep timer 6 7 ENERGY SAVING OPERATIONS 6 7 1 Economy operation 6 7 2 Fan control for energy saving 6 7 3 Demand Response 6 8 OTHER OPERATION 7 8 1 Powerful operation 7 9 SETTINGS ON INSTALLATION 7 9 1 Remote controller custom code setting 7 10 CLEANING AND CARE 7 11 GENERAL INFORMATION 8 12 OPTIONAL PARTS 9 12 1 Wired remote controller 9 13 TROUBLESHOOTING 9 ...

Page 2: ...or instruction concerning use of this product by a person responsible for their safety Children should be supervised to ensure that they do not play with this product Dispose of the packing materials safely Tear and dispose of the plastic packing bags so that children cannot play with them There is danger of suffocation if children play with the original plastic bags WARNING Do not start or stop t...

Page 3: ...re that the intake grille is closed completely Incomplete closing may affect the proper function or performance of the product 2 Indicator lamps light in the following conditions Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 3 2 Remote controller CAUTION To prevent malfunction or damage of the remote controller Place...

Page 4: ...rflow direction The setting must be done while the setting screen is displayed for each function The button is controllable only when the air conditioner is operating Signal transmitter Aim at the signal receiver of the indoor unit properly Operating range is approximately 7 m will appear when the signal is transmitted The indoor unit will emit a beep when it receives the sig nal properly If there...

Page 5: ...ouvers by hand Swing operation setting Press to start stop the Swing operation NOTE The Swing operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped Airflow direction range Up down airflow direction 1 2 3 4 5 6 Change by Cooling Dry 1 2 3 4 5 6 Heating Fan 1 2 3 4 5 6 Swing operation by Cooling Dry 1 4 Heating 3 6 Fan 1 4 or 3 6 The Swing operation rang...

Page 6: ... on the indoor unit will blink Blinking pattern and the intervals are as follows Operation mode Indicator lamp blinking pattern Auto Cooling Heating Dry Fan On Blinks 2 times When the DR mode finishes the air conditioner returns to the operation set before entering the DR mode 6 1 On timer or Off timer 1 Select On timer or Off timer in step 1 of Timer setting procedure 2 Each time you press the ti...

Page 7: ...troller controls When two or more air conditioners are in the room and you wish to operate them separately set the custom code 4 selections possible NOTE If custom codes are different between the indoor unit and the remote controller the indoor unit cannot receive a signal from the remote controller How to set the remote controller custom code 1 Press until the indicators on the remote controller ...

Page 8: ...ing performance of the product For frost protection an automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the Heating operation the outdoor unit will stop automatically ...

Page 9: ...eset the circuit breaker Is the timer operating To check or deactivate the timer setting refer to page 5 Poor cooling or heating performance Is the unit operating under the conditions except the permissible temperature range In this case the air conditioner may stop because of the automatic protection circuit working Do you have an arrangement with your electric company for Demand Response In this...

Page 10: ... See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 8 Filter indicator Clean the air filter and reset the filter sign 8 Demand response operation 6 Error code display Check the error code and consult authorized service personnel 10 Timer setting error because of Auto restart Reset the clock and timer settings 8 Test run operation for authorized...

Page 11: ......

Page 12: ......

Reviews: