Smell coming from the unit.

 

The air conditioner may absorb various smells generated from 

interior textile, furniture, or cigarette smoke. These smells may be 

emitted during the operation.

Mist or steam is emitted from the unit.

 

<In the Cooling or Dry mode> A thin mist may be generated by 

condensation formed with sudden cooling process.

 

<In the Heating mode> Is [  ] indicator on the indoor unit blinking?  

In this case, steam may rise from the outdoor unit because of the 

Automatic defrosting operation.(Refer to 

page 8

.)

Outdoor unit emits water.

 

<In the Heating mode> The outdoor unit may emit water gener-

ated by the Automatic defrosting operation. (Refer to 

page 8

.)

The unit operates differently from the remote controller setting.

 

Do you have an arrangement with your electric company for 

Demand Response?  

In this case, the air conditioning performance may become lower 

or the operation may stop. (Refer to 

page 6.

)

 

Are the batteries in the remote controller exhausted? 

 Replace the batteries.

Operation is delayed after restart.

 

Has the power supply turned from Off to On suddenly? 

 

In this case, the compressor will not operate for about 3 minutes 

to prevent a blowout of the fuse.

Immediately stop operation and turn off the electrical breaker in 

following cases. Then consult authorized service personnel.

•  The problem persists even if you perform these checks or 

diagnostics.

•  On the indoor unit, [  ] and [   ] blink while [   ] is blinking fast.

 

State of indicator lamps

Lighting pattern: 

 Off,   

 On,   

 Blinking,   

 Any state

State

Causes and solutions

See

page

Automatic defrosting operation

 Please wait until finishing the defrosting 

(maximum of 15 minutes).

8

Filter indicator

⇒  

Clean  the  air  filter  and  reset  the  filter 

sign.

8

Demand response operation

6

Error code display

⇒  

Check the error code and consult 

authorized service personnel.

10

Timer setting error because of Auto restart

⇒ 

Reset the clock and timer settings.

8

Test run operation (for authorized 

personnel only)

⇒ 

Press

 

 

  to quit the test run.

4

Restricted function

9

 

Manual Auto operation and Filter indicator 

reset

You can operate the air conditioner with

 

 

on the indoor unit.

Status

Length of pressing down Mode or operation

In operation More than 3 seconds

Stop

Stopping

2 seconds or less

Filter indicator reset

More than 3 seconds and 

less than 10 seconds

Auto

More than 10 seconds

(Only for servicing.) 

*

Forced cooling

*   To stop the forced cooling, press this button or

   

on the remote 

controller.

 

Service check

If [  ] and [   ] blink while [   ] is blinking fast on the indoor 

unit, check the error code. The error code is 2-digit numbers or 

characters. 

1. 

Press [ 

 ] 

The remote controller enters to the Service check mode and 

” will appear on the remote controller display. 

2. 

Press 

 to change the shown error code. 

  The indoor unit emits 1 short beep each time the error code 

changes. 

  When the corresponding error code is shown, the indoor 

unit emits multiple beeps and all the indicator lamps on the 

indoor unit blink. 

(Max. 2 min/cycle)

The characters used for error code

A

C

F

J

P

U

To finish the Service check mode, press 

The remote controller returns to the original display. 

Tell the error code to authorized service personnel when 

consulting them.

If the indoor unit emits multiple beeps at "00", no error is 

detected.

(Fast)

(3 times)

(Twice)

9333892030-02_OM_EN.indd   10

9333892030-02_OM_EN.indd   10

01/27/2022   08:35:08

01/27/2022   08:35:08

Summary of Contents for ASTH07KNCA

Page 1: ... Off timer 6 6 2 Program timer 6 6 3 Sleep timer 6 7 ENERGY SAVING OPERATIONS 6 7 1 Economy operation 6 7 2 Fan control for energy saving 6 7 3 Demand Response 6 8 OTHER OPERATION 7 8 1 Powerful operation 7 9 SETTINGS ON INSTALLATION 7 9 1 Remote controller custom code setting 7 10 CLEANING AND CARE 7 11 GENERAL INFORMATION 8 12 OPTIONAL PARTS 9 12 1 Wired remote controller 9 13 TROUBLESHOOTING 9 ...

Page 2: ...or instruction concerning use of this product by a person responsible for their safety Children should be supervised to ensure that they do not play with this product Dispose of the packing materials safely Tear and dispose of the plastic packing bags so that children cannot play with them There is danger of suffocation if children play with the original plastic bags WARNING Do not start or stop t...

Page 3: ...re that the intake grille is closed completely Incomplete closing may affect the proper function or performance of the product 2 Indicator lamps light in the following conditions Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 3 2 Remote controller CAUTION To prevent malfunction or damage of the remote controller Place...

Page 4: ...rflow direction The setting must be done while the setting screen is displayed for each function The button is controllable only when the air conditioner is operating Signal transmitter Aim at the signal receiver of the indoor unit properly Operating range is approximately 7 m will appear when the signal is transmitted The indoor unit will emit a beep when it receives the sig nal properly If there...

Page 5: ...ouvers by hand Swing operation setting Press to start stop the Swing operation NOTE The Swing operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped Airflow direction range Up down airflow direction 1 2 3 4 5 6 Change by Cooling Dry 1 2 3 4 5 6 Heating Fan 1 2 3 4 5 6 Swing operation by Cooling Dry 1 4 Heating 3 6 Fan 1 4 or 3 6 The Swing operation rang...

Page 6: ... on the indoor unit will blink Blinking pattern and the intervals are as follows Operation mode Indicator lamp blinking pattern Auto Cooling Heating Dry Fan On Blinks 2 times When the DR mode finishes the air conditioner returns to the operation set before entering the DR mode 6 1 On timer or Off timer 1 Select On timer or Off timer in step 1 of Timer setting procedure 2 Each time you press the ti...

Page 7: ...troller controls When two or more air conditioners are in the room and you wish to operate them separately set the custom code 4 selections possible NOTE If custom codes are different between the indoor unit and the remote controller the indoor unit cannot receive a signal from the remote controller How to set the remote controller custom code 1 Press until the indicators on the remote controller ...

Page 8: ...ing performance of the product For frost protection an automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the Heating operation the outdoor unit will stop automatically ...

Page 9: ...eset the circuit breaker Is the timer operating To check or deactivate the timer setting refer to page 5 Poor cooling or heating performance Is the unit operating under the conditions except the permissible temperature range In this case the air conditioner may stop because of the automatic protection circuit working Do you have an arrangement with your electric company for Demand Response In this...

Page 10: ... See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 8 Filter indicator Clean the air filter and reset the filter sign 8 Demand response operation 6 Error code display Check the error code and consult authorized service personnel 10 Timer setting error because of Auto restart Reset the clock and timer settings 8 Test run operation for authorized...