background image

En-9

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

General Informations on Operation

Auto-restart function

In event of power interruption such as a blackout, the air 

conditioner stops once. But it restarts automatically and 

performs previous operation when the power supply is resumed.

If any power interruption occurs after the timer is set, counting 

down of the timer will be reset. 

After the power supply is resumed, the TIMER indicator on the 

indoor unit blinks to notify you that there has been a timer fault. 

In such a case, reset the timer for your opportune time.

Malfunctions caused by other electrical devices:

Use of other electrical appliances such as an electric shaver or 

nearby use of a wireless radio transmitter may cause the malfunction 

of the air conditioner. 

If you encounter such a malfunction, turn off the circuit breaker once. 

Then turn it on again, and resume operation by using the remote 

controller.

Wired remote controller (option)

The optional wired remote controller can be used.

When you use remote controller, there are following different points 

as compared with using wireless remote controller.

[The additional functions for wired remote controller]

• Temperature set back timer
And you can use both wired and wireless remote controller 

simultaneously. (But function is limited.)

When the restricted functions on the remote controller are used, 

beeping sound will be heard, OPERATION, TIMER and the 

ECONOMY indicator of the indoor unit will flash.

[The restricted functions for wireless remote controller]

<Polar 3-core wired remote controller>

• Outdoor unit low noise

• Energy saving

• Powerful

• Timer operation

<Non-polar 2-core wired remote controller>

• Outdoor unit low noise

• Weekly timer

• Powerful

Temperature and Humidity Range

Permissible ranges of temperature and humidity are as follows:

COOL/DRY

Indoor temperature

About 18 °C to 32 °C

Indoor humidity

Below approximately 80%.

If the air conditioner is used continuously for many 

hours, water may condense on the surface and drip.

If the unit is used under higher temperature conditions than those noted here, the automatic protection circuit may operate, interrupting the operation.

If the unit is used under lower temperature conditions than those noted here, the heat exchanger may freeze, causing water leakage or other mal-

function.

  Do not use the air conditioner for any purpose other than room cooling/dry or fan.

  For the permissible ranges of temperature and humidity for the outdoor unit, refer to the outdoor unit installation manual.

Summary of Contents for ASTG30CMTA

Page 1: ...l breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personn...

Page 2: ...e this product directly to water Do not use this product for preservation of food plants animals precision equipment art work or other objects This may cause quality deterioration of those items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable Do not touch the aluminum fins of heat exchanger built in this pr...

Page 3: ...r will automatically return to position 3 Keeping the position 4 6 during COOL or DRY mode may cause condensation to form and the drops may damage your property 6 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow directi...

Page 4: ...n In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down the room When activated the indoor unit will emit 2 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 1 sh...

Page 5: ...ning of AUTO mode you cannot change the airflow direction See page 6 12 WEEKLY timer button Activates the WEEKLY timer for a maximum of 4 on or off programs per day each day of the week See page 6 13 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used...

Page 6: ...EEP timer press the SLEEP button while the SLEEP indicator is on Erases the indicator To help you to fall asleep comfortably and prevent excessive cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or D...

Page 7: ...he SEND button Press the NEXT button 7 Press the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer ...

Page 8: ...appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switche...

Page 9: ...for wired remote controller Temperature set back timer And you can use both wired and wireless remote controller simultaneously But function is limited When the restricted functions on the remote controller are used beeping sound will be heard OPERATION TIMER and the ECONOMY indicator of the indoor unit will flash The restricted functions for wireless remote controller Polar 3 core wired remote co...

Page 10: ...cloth 3 While holding the grille horizontal set the left and right mounting shafts into the pillow blocks at the top of the panel d To latch each shaft properly insert the shaft until it snaps Then close the intake grille e e e d d 4 Press 4 places on the intake grille to close it completely Cleaning the air filters 1 Open the intake grille and remove the air filters Lift up the air filter s handl...

Page 11: ...ilters They can not be washed and reused For storage of the filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated APPLE CATECHIN FILTER UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters...

Page 12: ...eed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operat...

Reviews: