background image

En-5

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

Remote Controller Overview and Operations (continued)

7  Signal transmitter

Aim at the signal receiver of the indoor unit properly.

• Signal transmit indicator   on the remote controller display shows 

that the signal from the remote controller is being transmitted.

• Operating range is approximately 7 m.

• You will hear a beep if the transmitted signal has been sent properly.  

If there is no beep, press the button on the remote controller again.

8  "FAN" button

Controls the fan speed.

(AUTO)

(HIGH)

(MED)

(LOW)

(QUIET)

• When AUTO is selected, the fan speed is automatically adjusted 

according to the operation mode.

9  "SWING" button

Sets the automatic swing operation. Each time the "SWING" button is 

pressed, the operation will change.

 Up/down 

Left/right 

Up/down/left/right 

Stop swing

• The Left/right swing operation will follow the direction as shown on 

page 3 "Horizontal airflow direction louver"

• The Up/down Swing operation range will differ by mode as follows:

COOL, DRY, or FAN 

mode

FAN mode

1

2

3

3

6

5

4

4

1

2

3

4

5 6

Notes:

• SWING operation may stop temporarily when the indoor unit fan is 

rotating at very low speed or is stopped.

• In FAN mode, the Up/down swing operation range of 1 

 4 or 3 

 

6 is decided according to the airflow direction previously set before 

starting the swing operation.

See page 3

10  "Vertical SET" button

Adjusts the vertical airflow direction.

Notes:

• At the beginning of AUTO mode, you cannot change the airflow 

direction.

See page 3

11  "Horizontal SET" button

Adjusts the horizontal airflow direction.

Notes:

• At the beginning of AUTO mode, you cannot change the airflow 

direction.

See page 6

12  "WEEKLY timer" button

Activates the WEEKLY timer for a maximum of 4 on or off programs 

per day, each day of the week.

See page 6

13  "SLEEP timer" button

Activates the SLEEP timer that helps you to fall asleep comfortably 

with gradual temperature control.

See page 6

14  "ON/OFF timer" button

Activates the ON/OFF timer.

15  "NEXT" button

Used for adjusting the timer setting.

16  "BACK" button

Used for adjusting the timer setting.

17  "RESET" button

When you press the "RESET" button, press it gently by using the tip 

of a ballpoint pen or other small object in correct direction as shown in 

this figure.

RESET

See page 2

18  "CLOCK ADJUST" button

Used for adjusting the clock.

19  "SEND" button

Used for sending the timer/clock setting.

See page 6

20  "TIMER SETTING" button

Used to enter the timer setting mode.

21  "SELECT" button

Used for adjusting the clock or timer.

22  "OUTDOOR UNIT LOW NOISE" button

Starts or stops OUTDOOR UNIT LOW NOISE operation that lowers 

noise generated from the outdoor unit by cutting down the rotation 

number of the compressor, and suppressing the fan speed.

Once the operation is set, the setting is preserved until you press this 

button again to stop the operation, even if the indoor unit operation is 

stopped.

 on the remote controller display shows that the unit is in 

OUTDOOR UNIT LOW NOISE mode.

Notes:

• This operation cannot be performed simultaneously with FAN, DRY 

and POWERFUL operation modes.

See page 8

23  "SENSOR" button (ENERGY SAVING PROGRAM)

Activates or deactivates the energy saving program. 

* The Energy Saving program is ON at the time of purchase.

:   The setting must be done while the setting screen is displayed for 

each function.

 :  The button is controllable only when the air conditioner is on.

Summary of Contents for ASTG30CMTA

Page 1: ...l breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personn...

Page 2: ...e this product directly to water Do not use this product for preservation of food plants animals precision equipment art work or other objects This may cause quality deterioration of those items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable Do not touch the aluminum fins of heat exchanger built in this pr...

Page 3: ...r will automatically return to position 3 Keeping the position 4 6 during COOL or DRY mode may cause condensation to form and the drops may damage your property 6 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow directi...

Page 4: ...n In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down the room When activated the indoor unit will emit 2 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 1 sh...

Page 5: ...ning of AUTO mode you cannot change the airflow direction See page 6 12 WEEKLY timer button Activates the WEEKLY timer for a maximum of 4 on or off programs per day each day of the week See page 6 13 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used...

Page 6: ...EEP timer press the SLEEP button while the SLEEP indicator is on Erases the indicator To help you to fall asleep comfortably and prevent excessive cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or D...

Page 7: ...he SEND button Press the NEXT button 7 Press the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer ...

Page 8: ...appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switche...

Page 9: ...for wired remote controller Temperature set back timer And you can use both wired and wireless remote controller simultaneously But function is limited When the restricted functions on the remote controller are used beeping sound will be heard OPERATION TIMER and the ECONOMY indicator of the indoor unit will flash The restricted functions for wireless remote controller Polar 3 core wired remote co...

Page 10: ...cloth 3 While holding the grille horizontal set the left and right mounting shafts into the pillow blocks at the top of the panel d To latch each shaft properly insert the shaft until it snaps Then close the intake grille e e e d d 4 Press 4 places on the intake grille to close it completely Cleaning the air filters 1 Open the intake grille and remove the air filters Lift up the air filter s handl...

Page 11: ...ilters They can not be washed and reused For storage of the filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated APPLE CATECHIN FILTER UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters...

Page 12: ...eed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operat...

Reviews: