background image

En-3

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

1  Intake grille

Before starting operation, make sure that the intake grille has been 

shut completely. Incomplete closing may have an effect on the proper 

function or performance of the product.

2  "MANUAL AUTO" button

Use when the remote controller is lost or there is a malfunction.

Status

Action

Mode or operation

In operation

Press.

Stop

Stopping

Press less than 10 seconds.

AUTO

Press more than 10 seconds.

(Only for servicing.*)

Forced cooling

*:To stop forced cooling, press this button or "Start/Stop(

)" button 

on the remote controller.

3  Front panel

See page 8

4  Human Sensor

Used for Energy Saving Program. Controls temperature setting by 

detecting people in the room.

Vertical airflow direction louver

Each time you press "Vertical SET" button on the remote controller, 

the angle of the vertical airflow direction louver moves as follows:

1

2

3

4

5 6

COOL, DRY or FAN 

mode**

FAN mode

1

2

3

6

5

*

4

*: Default setting in each mode.

**: Suggested setting range

• Do not adjust by hand.

• At the beginning of AUTO mode, they may stay on position 1 for a 

while for adjustment.

• If the angle is set to position 4-6 for more than 20 minutes in COOL 

or DRY mode, the louver will automatically return to position 3.

• Keeping the position 4-6 during COOL or DRY mode may cause 

condensation to form, and the drops may damage your property.

Horizontal airflow direction louver

Each time you press the "Horizontal SET" button on the remote 

controller, the airflow direction range of the horizontal airflow direction 

louver will change as follows: 

1

2

3

4

5

Horizontal airflow direction louver

5

4

1

3

*

2

*: Default setting.

7  Drain hose

Remote controller signal receiver

 

CAUTION

For appropriate signal transmission between remote controller and 

indoor unit, keep the signal receiver away from the following items:

 -Direct sunlight or other strong lights

 -Flat-panel television screen

In rooms with instantaneous fluorescent lights, such as in-

verter type ones, the signal may not be transmitted properly. In 

such a case, consult the store of purchase.

13

1

2

3

4
5

8
9

7

6

10

11

12

9  ECONOMY indicator (green)

Lights in ECONOMY operation.

10  TIMER indicator (orange)

Lights in TIMER operation, and blinks slowly when the timer setting 

error is detected.

For details, refer to “Auto-restart function” on page 9.

11  OPERATION indicator (green)

Lights in normal operation, and blinks during Demand Response 

operation. For details, refer to page 8.

See page 10

12 

Air filter

See page 11

13 

Air cleaning filters

Purify or deodorize the air, and provide fresh airflow

Indoor Unit Overview and Operations

Summary of Contents for ASTG30CMTA

Page 1: ...l breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personn...

Page 2: ...e this product directly to water Do not use this product for preservation of food plants animals precision equipment art work or other objects This may cause quality deterioration of those items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable Do not touch the aluminum fins of heat exchanger built in this pr...

Page 3: ...r will automatically return to position 3 Keeping the position 4 6 during COOL or DRY mode may cause condensation to form and the drops may damage your property 6 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow directi...

Page 4: ...n In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down the room When activated the indoor unit will emit 2 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 1 sh...

Page 5: ...ning of AUTO mode you cannot change the airflow direction See page 6 12 WEEKLY timer button Activates the WEEKLY timer for a maximum of 4 on or off programs per day each day of the week See page 6 13 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used...

Page 6: ...EEP timer press the SLEEP button while the SLEEP indicator is on Erases the indicator To help you to fall asleep comfortably and prevent excessive cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or D...

Page 7: ...he SEND button Press the NEXT button 7 Press the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer ...

Page 8: ...appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switche...

Page 9: ...for wired remote controller Temperature set back timer And you can use both wired and wireless remote controller simultaneously But function is limited When the restricted functions on the remote controller are used beeping sound will be heard OPERATION TIMER and the ECONOMY indicator of the indoor unit will flash The restricted functions for wireless remote controller Polar 3 core wired remote co...

Page 10: ...cloth 3 While holding the grille horizontal set the left and right mounting shafts into the pillow blocks at the top of the panel d To latch each shaft properly insert the shaft until it snaps Then close the intake grille e e e d d 4 Press 4 places on the intake grille to close it completely Cleaning the air filters 1 Open the intake grille and remove the air filters Lift up the air filter s handl...

Page 11: ...ilters They can not be washed and reused For storage of the filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated APPLE CATECHIN FILTER UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters...

Page 12: ...eed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operat...

Reviews: