background image

En-11

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

Cleaning and Care (continued)

Air cleaning filter installation

1

  Open the intake grille and remove the air filters.

Air filter (Right & Left)

2

  Install the air cleaning filter set (set of 2).

  (1) Set the air cleaning filter into the air cleaning filter frame.

Air cleaning filter

Air cleaning filter frame

  (2) Engage the latch at both ends of the filter with the two hooks 

at the rear of the air cleaning filter frame.

Hook (2 places at the rear)

Latch (2 places)

Take care that the air cleaning filter does not project beyond the 

frame.

  (3) Engage the six fixing locations at the top and bottom of the air 

cleaning filter frame with the hooks of the air filter.

Rear of the filter

Fixing location, 

hook (6 places)

3

  Install the two air filters and close the intake grille.

• When air cleaning filters are used, the effect will increased by 

setting the fan speed to “HIGH”.

Replacing dirty air cleaning filters

Replace filters with the following components (purchased separately).

• APPLE-CATECHIN FILTER: UTR-FA13-1
• ION DEODORIZATION FILTER: UTR-FA13-2

1

  Open the intake grille and remove the air filters.

2

  Replace them by two new air cleaning filters.

  (1) Remove the old air cleaning filters in reverse order of their 

installation.

  (2) Install in the same way as for installation of the air cleaning 

filter set.

3

  Install the two air filters and close the intake grille.

[In regard to the air cleaning filters]

APPLE-CATECHIN FILTER (1 sheet)

• The filters are disposable filters. (They can not be washed and 

reused.)

• For storage of the filters, use the filters as soon as possible after the 

package has been opened.

(The air cleaning effect decreases when the filters are left in the 

opened package)

• Generally, the filters should be exchanged about every 3 months.

Please buy dedicated APPLE-CATECHIN FILTER (UTR-FA13-1) 

(Sold separately) to exchange the used dirty air cleaning filters.

ION DEODORIZATION FILTER (1 sheet) - light blue

• The filters should be exchanged about every 3 years so as to 

maintain the deodorizing effect.

Please buy dedicated ION DEODORIZATION FILTER (UTR-FA13-2) 

(Sold separately) when exchanging the filters.

[Maintenance of ION DEODORIZATION FILTER]

In order to maintain the deodorizing effect, please clean the filter in the 

following way every 3 months.

1.

  Remove the filter.

2.

  Clean with water and dry in the air.

  (1) Flush the filters with high-pressure hot water until the surface 

of the filters are covered with water. Please flush with diluent 

neutral detergent.

(Never wash by reaming or rubbing, otherwise it will damage 

the deodorizing effect.)

  (2) Rinse with water flow.

  (3) Dry in shade.

3.

  Reinstall the filter.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 

FAN operation for half a day to dry the internal parts throughly before 

you perform normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 

reduce the product performance even if you have maintained the unit 

with instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.

Summary of Contents for ASTG30CMTA

Page 1: ...l breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personn...

Page 2: ...e this product directly to water Do not use this product for preservation of food plants animals precision equipment art work or other objects This may cause quality deterioration of those items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable Do not touch the aluminum fins of heat exchanger built in this pr...

Page 3: ...r will automatically return to position 3 Keeping the position 4 6 during COOL or DRY mode may cause condensation to form and the drops may damage your property 6 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow directi...

Page 4: ...n In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down the room When activated the indoor unit will emit 2 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 1 sh...

Page 5: ...ning of AUTO mode you cannot change the airflow direction See page 6 12 WEEKLY timer button Activates the WEEKLY timer for a maximum of 4 on or off programs per day each day of the week See page 6 13 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used...

Page 6: ...EEP timer press the SLEEP button while the SLEEP indicator is on Erases the indicator To help you to fall asleep comfortably and prevent excessive cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or D...

Page 7: ...he SEND button Press the NEXT button 7 Press the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer ...

Page 8: ...appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switche...

Page 9: ...for wired remote controller Temperature set back timer And you can use both wired and wireless remote controller simultaneously But function is limited When the restricted functions on the remote controller are used beeping sound will be heard OPERATION TIMER and the ECONOMY indicator of the indoor unit will flash The restricted functions for wireless remote controller Polar 3 core wired remote co...

Page 10: ...cloth 3 While holding the grille horizontal set the left and right mounting shafts into the pillow blocks at the top of the panel d To latch each shaft properly insert the shaft until it snaps Then close the intake grille e e e d d 4 Press 4 places on the intake grille to close it completely Cleaning the air filters 1 Open the intake grille and remove the air filters Lift up the air filter s handl...

Page 11: ...ilters They can not be washed and reused For storage of the filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated APPLE CATECHIN FILTER UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters...

Page 12: ...eed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operat...

Reviews: