Safety Precautions

To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the 

following safety precautions.

Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows:

 

WARNING

 

CAUTION

This mark warns of death or serious injury.

This mark warns of injury or damage to property.

 This mark denotes an action that is PROHIBITED.

 This mark denotes an action that is COMPULSORY.

• Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposure to an external 

ignition source, there is a risk of fire.

CAUTION

This symbol shows that the Operation Manual should be read carefully.

CAUTION

This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.

CAUTION

This symbol shows that information is available such as the Operating Manual or Installation Manual.

 

WARNING

• The appliance, outlet and inlet shall be installed, operated 

and stored in a room with a floor area larger than X m

2

30 type

M (kg)

M ≤ 1.65

1.65 < M ≤ 2.05 2.05 < M ≤ 2.45 2.45 < M ≤ 2.85

X (m

2

)

2.60

4.01

5.72

7.74

34 type

M (kg)

M ≤ 2.00

2.00 < M ≤ 2.45 2.45 < M ≤ 2.90

X (m

2

)

3.81

5.72

8.02

M (kg): Amount of refrigerant charge                       ( IEC 60335-2-40 ) 
X (m

2

): Minimum room area

• The appliance shall be installed, operated and stored in a 

room with a floor area larger than 2.06m

2

.

• The appliance contains no user-serviceable parts. Always 

consult authorized service personnel for repairing, installation, 

and relocation of this product.

  Improper installation or handling will cause leakage, electric 

shock, or fire.

• In the event of a malfunction such as burning smell, 

immediately stop operation of the air conditioner, and 

disconnect all the power supply by turning off the electrical 

breaker or disconnecting the power plug. Then consult 

authorized service personnel.

• Take care not to damage the power supply cable. 

If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons 

in order to avoid a hazard.

• In the event of refrigerant leakage, be sure to keep away 

from fire or any flammables, and consult authorized service 

personnel.

• If you see lightning or hear thunder, there might be a lightning 

strike. 

To prevent electric shock hazard, turn off the air conditioner 

by using the remote controller, and do not touch this product 

or the power source during thunderstorm.

• The appliance shall be stored in a room without continuously 

operating ignition sources (for example: open flames, an 

operating gas appliance or an operating electric heater).

• The appliance shall be stored in a well-ventilated area.

• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical 

damage from occurring.

• Disposing of the product shall be done properly, in 

compliance with national or regional regulations.

• During transportation or relocation of the indoor unit, pipes 

shall be covered with the wall hook bracket for protection. 

Do not move the appliance by holding the indoor unit pipes. 

(The stress applied to the pipe joints may cause the 

flammable gas to leak during operation).

(continued)

Contents

Safety Precautions ..........................................................En-1
Indoor Unit Overview and Operations .............................En-3
Remote Controller Overview and Operations ..................En-4
Timer Operation...............................................................En-6
Human Sensor (Energy Saving) ......................................En-8
Demand Response and Indoor Unit Operation ...............En-8
General Informations on Operation .................................En-9
Cleaning and Care.........................................................En-10
Troubleshooting .............................................................En-12

R32

REFRIGERANT

This Air Conditioner contains and 

operates with refrigerant R32.

THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED

BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,

regulations, codes, installation & operation manuals, before 

the installation, maintenance or service of this product.

PART No. 9387081022

Before using this product, read these instructions thoroughly. Also, keep this manual for future reference, 

together with the installation manuals for the indoor and outdoor units.

Summary of Contents for ASTG30CMTA

Page 1: ...l breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personn...

Page 2: ...e this product directly to water Do not use this product for preservation of food plants animals precision equipment art work or other objects This may cause quality deterioration of those items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable Do not touch the aluminum fins of heat exchanger built in this pr...

Page 3: ...r will automatically return to position 3 Keeping the position 4 6 during COOL or DRY mode may cause condensation to form and the drops may damage your property 6 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow directi...

Page 4: ...n In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down the room When activated the indoor unit will emit 2 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 1 sh...

Page 5: ...ning of AUTO mode you cannot change the airflow direction See page 6 12 WEEKLY timer button Activates the WEEKLY timer for a maximum of 4 on or off programs per day each day of the week See page 6 13 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used...

Page 6: ...EEP timer press the SLEEP button while the SLEEP indicator is on Erases the indicator To help you to fall asleep comfortably and prevent excessive cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or D...

Page 7: ...he SEND button Press the NEXT button 7 Press the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer ...

Page 8: ...appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switche...

Page 9: ...for wired remote controller Temperature set back timer And you can use both wired and wireless remote controller simultaneously But function is limited When the restricted functions on the remote controller are used beeping sound will be heard OPERATION TIMER and the ECONOMY indicator of the indoor unit will flash The restricted functions for wireless remote controller Polar 3 core wired remote co...

Page 10: ...cloth 3 While holding the grille horizontal set the left and right mounting shafts into the pillow blocks at the top of the panel d To latch each shaft properly insert the shaft until it snaps Then close the intake grille e e e d d 4 Press 4 places on the intake grille to close it completely Cleaning the air filters 1 Open the intake grille and remove the air filters Lift up the air filter s handl...

Page 11: ...ilters They can not be washed and reused For storage of the filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated APPLE CATECHIN FILTER UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters...

Page 12: ...eed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operat...