background image

En-12

OPERATING MANUAL

 

WARNING

In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical 

breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel.

As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.

• Unit smells of something burning or emits smoke

• Water leaks from the unit

Following symptoms do not indicate product malfunction, but they are normal functions or characteristics of this product.

Symptom

Cause

See page

Operation is delayed after 

restart.

To prevent blowout of the fuse, the compressor will not operate while the protection circuit is working 

for about 3 minutes after sudden OFF→ON operation of the power supply.

Noise is heard.

During operation or immediately after stopping the air conditioner, refrigerant flowing sound may be 

heard. Also it may be particularly noticeable for 2–3 minutes after starting operation.

During the operation, a slight squeaking sound produced by the minute expansion and contraction of 

the front panel caused by temperature change may be heard.

Smell coming from the unit.

Various smells generated from interior textile, furniture, or cigarette smoke absorbed into the air 

conditioner may be emitted.

Mist or steam is emitted from 

the unit.

In COOL or DRY mode, a thin mist generated by condensation formed with sudden cooling process 

may be emitted.

Airflow is weak or stops.

In DRY mode, the indoor unit operates at low fan speed to adjust the room humidity, and may stop 

from time to time.

When the fan speed is set to “QUIET”, the fan rotates at very low speed and the airflow is reduced.

In COOL mode, the indoor unit fan may stop from time to time when the outdoor unit is stopped.

4

When monitoring operation is performed in AUTO mode, the fan rotates at very low speed.

Before you call for or request servicing, troubleshoot a problem by performing following checks:

Symptom

Diagnostic

See page

Does not operate at all.

 Has the circuit breaker been turned off?

 Has there been a power outage?

 Has a fuse blown out or the circuit breaker been tripped?

 Is the timer operating? 

6

Poor cooling performance.

 Is the air filter dirty? 

10

 Is the intake grill or outlet port of indoor unit blocked?

 Is the room temperature adjusted appropriately?

4

 Is a window or door left opened?

 Is direct or strong sunlight shinning into the room in cooling operation?

  Are there other heating apparatus or computers operating, or too many people in the room in cool-

ing operation?

  Is the fan speed set to “QUIET”? 

When the fan speed setting is set to “QUIET”, noise reduction is prioritized and the air-conditioning 

performance may become lower. If the volume of provided airflow is not agreeable to your prefer-

ence, set the fan speed to “LOW” or higher fan speed.

5

 Has the OUTDOOR UNIT LOW NOISE mode been set?

5

 Do you have an arrangement with your electric company for Demand Response?

8

The unit operates differently 

from the remote controller 

setting.

 Are the batteries used in the remote controller exhausted?

 Are the batteries used in the remote controller loaded properly?

2

Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.

• The problem persists even if you perform these checks or diagnostics.

• The OPERATION indicator and TIMER indicator blink while the ECONOMY indicator is blinking fast.

Troubleshooting

Summary of Contents for ASTG30CMTA

Page 1: ...l breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personn...

Page 2: ...e this product directly to water Do not use this product for preservation of food plants animals precision equipment art work or other objects This may cause quality deterioration of those items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable Do not touch the aluminum fins of heat exchanger built in this pr...

Page 3: ...r will automatically return to position 3 Keeping the position 4 6 during COOL or DRY mode may cause condensation to form and the drops may damage your property 6 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow directi...

Page 4: ...n In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down the room When activated the indoor unit will emit 2 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 1 sh...

Page 5: ...ning of AUTO mode you cannot change the airflow direction See page 6 12 WEEKLY timer button Activates the WEEKLY timer for a maximum of 4 on or off programs per day each day of the week See page 6 13 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used...

Page 6: ...EEP timer press the SLEEP button while the SLEEP indicator is on Erases the indicator To help you to fall asleep comfortably and prevent excessive cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or D...

Page 7: ...he SEND button Press the NEXT button 7 Press the SELECT button to set the temperature If you want to move on to the next setting press the NEXT button return to step 4 and configure the next setting 8 To complete the setting press the SEND button If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button Notes When canceling the WEEKLY timer ...

Page 8: ...appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switche...

Page 9: ...for wired remote controller Temperature set back timer And you can use both wired and wireless remote controller simultaneously But function is limited When the restricted functions on the remote controller are used beeping sound will be heard OPERATION TIMER and the ECONOMY indicator of the indoor unit will flash The restricted functions for wireless remote controller Polar 3 core wired remote co...

Page 10: ...cloth 3 While holding the grille horizontal set the left and right mounting shafts into the pillow blocks at the top of the panel d To latch each shaft properly insert the shaft until it snaps Then close the intake grille e e e d d 4 Press 4 places on the intake grille to close it completely Cleaning the air filters 1 Open the intake grille and remove the air filters Lift up the air filter s handl...

Page 11: ...ilters They can not be washed and reused For storage of the filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated APPLE CATECHIN FILTER UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters...

Page 12: ...eed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operat...

Reviews: