background image

En-14

Filter Indicator Reset (The special setting)

•  Can be used if set correctly during installation.

Please consult authorized serviceman when using this function. 

•  It lights on when it is time to clean the air  lters. 

Clean the  lter referring to “CLEANING AND CARE”. 
After cleaning, press the MANUAL AUTO button (Fig. 2 

2

) for 2 seconds or less on 

the indoor unit.

OPERATION

●   

Indicator Lamp

   

 

Flashing

: OFF

TIMER

ECONOMY

CLEANING AND CARE

SELECTING THE REMOTE CONTROLLER SIGNAL CODE

When two or more air conditioners are installed in a room and the Remote Controller is operating an air conditioner other than the 
one you wish to set, change the signal code of the Remote Controller to operate only the air conditioner you wish to set (4 selections 
possible).
When two or more air conditioners are installed in a room, please contact your retailer to set the individual air conditioner signal 
codes.

Selecting the Remote Controller Signal Code

Use the following steps to select the signal code of the Remote Controller. (Note that 
the air conditioner cannot receive a signal code if the air conditioner has not been set 
for the signal code.)

1

  Press the START/STOP button until only the clock is 

displayed on the Remote Controller display.

2

  Press the MODE button for at least five seconds to 

display the current signal code (initially set to  ).

3

  Press the (

 / 

) buttons to change the signal code 

between

 

. Match the code on the display 

to the air conditioner signal code.

4

  Press the MODE button again to return to the clock 

display. The signal code will be changed.

  If no buttons are pressed within 30 seconds after the signal code is displayed, the system returns to the original clock display. In this case, 

start again from step 1.

  The air conditioner signal code is set to A prior to shipment. Contact your retailer to change the signal code.
  The Remote Controller resets to signal code A when the batteries in the Remote Controller are replaced. If you use a signal code other than 

signal code A, reset the signal code after replacing the batteries.

    If you do not know the air conditioner signal code setting, try each of the signal codes (

) until you  nd the code which operates the 

air conditioner.

9315345509_OM_EN.indb   14

2012-7-17   17:17:00

Summary of Contents for ASTG24JF

Page 1: ...e COOL MODEL R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product PART No 9315345509 ...

Page 2: ...conditioner with wet hands Do not pull power supply cord Turn off power supply when not using the indoor unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air ow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipm...

Page 3: ...ooling or dry mode the thermostat setting is gradually raised during the pe riod of operation When the set time is reached the unit auto matically turns off Clean function REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care ...

Page 4: ...xplanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 1 Fig 2 Fig 3 Fig 4 NAME OF PARTS ...

Page 5: ...R Display Y Transmit Indicator Z Fan Speed Display SWING Display Timer Mode Display Clock Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced...

Page 6: ...e arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 5 R Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 5 Q to adjust the clock to the current time button Press to advance the time button Press to rev...

Page 7: ...d a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN button Fig 5 K Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermostat setting the fan speed becomes slowe...

Page 8: ...ooling to adjust the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust...

Page 9: ...orange Fig 3 6 will light 3 Use the TIMER SET buttons Fig 5 Q to adjust the desired OFF time or ON time Set the time while the time display is ashing the ashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program timer 1 Press the START STOP button Fig 5 L if the unit is alread...

Page 10: ...out 5 seconds later the entire display will reappear To Cancel the Timer Use the TIMER MODE button to select CANCEL The air conditioner will return to normal operation To Stop the Air Conditioner During Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive cooling during sleep the SLEEP timer function automatically modi es the thermostat setting in accordance with ...

Page 11: ...ill automatically return to position 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 5 M Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air ow Direction Setting 1 2 3 ...

Page 12: ...operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button Fig 5 H The ECONOMY Indicator Lamp green Fig 3 7 will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button Fig 5 H again The ECONOMY Indicator Lamp green Fig 3 7 will go out Normal operation begins About ECONOMY Operation When ECONOMY operation mode is operated the room...

Page 13: ... thoroughly in a shaded place 3 Replace the Air Filter and close the Intake Grille 1 Align the sides of the air lter with the panel and push in fully making sure the 2 lower tabs are returned prop erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit with out Intake Grille installed Dust can be cleaned from the air lter either with a vac...

Page 14: ...re disposable lters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the lters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated air cleaning lters UTR FA13 1 Sold separately to exchange the used dirty...

Page 15: ...he Remote Controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code 1 Press the START STOP button until only the clock is displayed on the Remote Controller display 2 Press the MODE button for at least five seconds to display the current signal code initially set to 3 Press the buttons to change the signal code between Match t...

Page 16: ...he indoor unit This results from the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in condensation and misting Air ow is weak or stops During Dry mode the indoor unit will operate at low speed in order to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity 7 During SUPER QU...

Page 17: ...g TIMER operation the timer will be reset and the indoor unit will begin or stop op eration at the new time setting In the event that this kind of timer fault occurs the TIMER Indicator Lamp will ash see Page 3 Use of other electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily turn off the circ...

Page 18: ......

Reviews: