En-13

Air Cleaning Filter Installation

1. Open the Intake Grille and remove the Air 

 lters.

2. Install the Air cleaning  lter set (set of 2).

1

 Set the air cleaning  lter into the air cleaning  lter frame.

2

 Engage the latch at both ends of the filter with the 2 

hooks at the rear of the air cleaning  lter frame.

Take care that the air cleaning  lter does not project beyond 
the frame.

3

 Engage the 6  xing locations at the top and bottom of 

the air cleaning  lter frame with the hooks of the air  l-
ter.

3. Install the 2 Air filters and close the 

Intake Grille.

  When air cleaning  lters are used, the effect will increased 

by setting the fan speed to “High”.

Replacing dirty Air cleaning  lters

Replace  lters with the following components (purchased sep-
arately).

  POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FA13-1

  Negative air ions deodorizing  lter: UTR-FA13-2

1. Open the Intake Grille and remove the Air 

 lters.

2. Replace them by 2 new Air cleaning 

 lters.

1

 Remove the old air cleaning  lters in reverse order of 

their installation.

2

 Install in the same way as for installation of the air 

cleaning  lter set.

3. Install the 2 Air filters and close the 

Intake Grille.

In regard to the Air Cleaning Filters

POLYPHENOL CATECHIN AIR CLEANING FILTER (1 sheet)

  The Air Cleaning Filters are disposable  lters. (They can not 

be washed and reused.)

 For storage of the Air Cleaning Filters, use the filters as 

soon as possible after the package has been opened.

 

(The air cleaning effect decreases when the  lters are left in 
the opened package)

 Generally, the filters should be exchanged about every 

3 months.

Please buy dedicated air cleaning  lters (UTR-FA13-1) (Sold 
separately) to exchange the used dirty air cleaning  lters. 

[Negative air ions deodorizing  lter (1 sheet) — light blue]

  The  lters should be exchanged about every 3 years so as 

to maintain the deodorizing effect.

  Filter frame is not a one-off product.

Please buy dedicated deodorizing  lter (UTR-FA13-2) (Sold 
separately) when exchanging the  lters.

Maintenance of Deodorizing Filters

In order to maintain the deodorizing effect, please clean the 
 lter in the follow way once 3 months.

1

 Remove the deodorizing  lter.

2

 Clean with water and dry in the air.

1) Flush the  lters with high-pressure hot water until the 

surface of the  lters are covered with water. Please 
 ush with diluent neutral detergent. 

  Never wash by reaming or rubbing, otherwise it 

will damage the deodorizing effect.

2)  Rinse with water  ow.
3)  Dry in shade. 

3

 Reinstall the deodorizing  lter.

Hook (2 places at the rear)

Latch (2 places)

CLEANING AND CARE

Air Filter (Right & Left)

Air cleaning  lter frame

Air cleaning  lter

Air cleaning  lter set

Air Filter (Right & Left)

Air Filter (Right & Left)

Air Filter (Right & Left)

Rear of the  lter

Fixing location, hook (6 places)

9315345509_OM_EN.indb   13

2012-7-17   17:17:00

Summary of Contents for ASTG24JF

Page 1: ...e COOL MODEL R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product PART No 9315345509 ...

Page 2: ...conditioner with wet hands Do not pull power supply cord Turn off power supply when not using the indoor unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air ow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipm...

Page 3: ...ooling or dry mode the thermostat setting is gradually raised during the pe riod of operation When the set time is reached the unit auto matically turns off Clean function REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care ...

Page 4: ...xplanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 1 Fig 2 Fig 3 Fig 4 NAME OF PARTS ...

Page 5: ...R Display Y Transmit Indicator Z Fan Speed Display SWING Display Timer Mode Display Clock Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When the MANUAL AUTO button is pressed in for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced...

Page 6: ...e arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 5 R Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 5 Q to adjust the clock to the current time button Press to advance the time button Press to rev...

Page 7: ...d a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN button Fig 5 K Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermostat setting the fan speed becomes slowe...

Page 8: ...ooling to adjust the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust...

Page 9: ...orange Fig 3 6 will light 3 Use the TIMER SET buttons Fig 5 Q to adjust the desired OFF time or ON time Set the time while the time display is ashing the ashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program timer 1 Press the START STOP button Fig 5 L if the unit is alread...

Page 10: ...out 5 seconds later the entire display will reappear To Cancel the Timer Use the TIMER MODE button to select CANCEL The air conditioner will return to normal operation To Stop the Air Conditioner During Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive cooling during sleep the SLEEP timer function automatically modi es the thermostat setting in accordance with ...

Page 11: ...ill automatically return to position 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 5 M Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air ow Direction Setting 1 2 3 ...

Page 12: ...operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button Fig 5 H The ECONOMY Indicator Lamp green Fig 3 7 will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button Fig 5 H again The ECONOMY Indicator Lamp green Fig 3 7 will go out Normal operation begins About ECONOMY Operation When ECONOMY operation mode is operated the room...

Page 13: ... thoroughly in a shaded place 3 Replace the Air Filter and close the Intake Grille 1 Align the sides of the air lter with the panel and push in fully making sure the 2 lower tabs are returned prop erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit with out Intake Grille installed Dust can be cleaned from the air lter either with a vac...

Page 14: ...re disposable lters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the lters are left in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated air cleaning lters UTR FA13 1 Sold separately to exchange the used dirty...

Page 15: ...he Remote Controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code 1 Press the START STOP button until only the clock is displayed on the Remote Controller display 2 Press the MODE button for at least five seconds to display the current signal code initially set to 3 Press the buttons to change the signal code between Match t...

Page 16: ...he indoor unit This results from the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in condensation and misting Air ow is weak or stops During Dry mode the indoor unit will operate at low speed in order to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity 7 During SUPER QU...

Page 17: ...g TIMER operation the timer will be reset and the indoor unit will begin or stop op eration at the new time setting In the event that this kind of timer fault occurs the TIMER Indicator Lamp will ash see Page 3 Use of other electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily turn off the circ...

Page 18: ......

Reviews: