En-3

3.  SELECTING THE MOUNTING POSITION

With  considering written conditions below, select an appropriate installing location in 
consultation with the customer.

 WARNING

Securely install the outdoor unit at a location that can withstand the weight of the unit. 
Otherwise, the outdoor unit may fall and cause injury.

Be sure to install the outdoor unit as prescribed, so that it can withstand earthquakes 
or strong winds. Improper installation can cause the unit to topple or fall, or other 
accidents.

 CAUTION

Do not install the outdoor unit in the following areas:

• Area with high salt content, such as at the seaside. It will deteriorate metal parts, 

causing the parts to fail or the unit to leak water.

• Area 

fi

 lled with mineral oil or containing a large amount of splashed oil or steam. It will 

deteriorate plastic parts, causing the parts to fail or the unit to leak water.

• Area that generates substances that adversely affect the equipment, such as sulfuric 

gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed joints to 
corrode, which can cause refrigerant leakage.

• Area containing equipment that generates electromagnetic interference. It will cause 

the control system to malfunction, preventing the unit from operating normally.

• Area that can cause combustible gas to leak, contains suspended carbon 

fi

 bers or 

fl

 ammable dust, or volatile in

fl

 ammables such as paint thinner or gasoline. If gas leaks 

and settles around the unit, it can cause a 

fi

 re.

• Area that has heat sources, vapors, or the risk of the leakage of 

fl

 ammable gas in the 

vicinity.

• Area where small animals may live. It may cause failure, smoke or 

fi

 re if small ani-

mals enter and touch internal electrical parts.

• Area where animals may urinate on the unit or ammonia may be generated.

(1) If possible, do not install the unit where it will be exposed to direct sunlight. 

(If necessary, Install a blind that does not interfere with the air 

fl

 ow.)

(2)  Do not install the unit where a strong wind blows or where it is very dusty.
(3)  Do not install the unit where people pass.
(4)  Take you neighbors into consideration so that they are not disturbed by air blowing 

into their windows or by noise.

(5)  Provide the space shown in 

fi

 gure so that the air 

fl

 ow is not blocked. Also for ef-

fi

 cient operation, leave open three of the four directions front, rear, and both sides.

(6)  Install the unit where keep away more than 3m from the antenna of TV set and 

Radio.

(7)  Outdoor unit should be set to a place where both drainage and itself will not be af-

fected when heating.

•  When there are obstacles at the back side.

AIR

100 mm

or more

•  When there are obstacles at the back and front sides.

AIR

600 mm

or more

100 mm

or more

•  When there are obstacles at the back, side(s), and top.

100-300 mm*

250 mm or more 

(Service space)

AIR

300 mm

or more

600mm or more

*  If the space is larger than that is stated, the condition will be the same as that there are 

no obstacles.

•  When there are obstacles at the back side with the installation of more than one unit.

AIR

250 mm 

or more

250 mm 

or more

300 mm

or more

4. INSTALLATION DIAGRAM

[OUTDOOR UNIT]

5 cm or over

INDOOR UNIT

•  Fix securely with bolts on a solid 

block. (Use 4 sets of commercially 
available M10 bolt, nut and washer.)

•  Do not directly install it on the ground, 

otherwise it will cause failure.

Outdoor unit 
bottom

54 cm

32 cm

Drain hose

Bolt

Nut

Block

Power 

supply 

cable

9377863133_IM.indb   3

9377863133_IM.indb   3

11/25/2011   11:30:56 AM

11/25/2011   11:30:56 AM

Summary of Contents for AOYG12-14LBLA

Page 1: ... INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION...

Page 2: ... in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not place any other electrical products or household belongings under indoor unit or outdoor unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Be careful not to scratch the air conditioner when handling it After installation explain correct...

Page 3: ...Application Installation Manual 1 This manual Drain pipe 1 For outdoor unit drain piping work Adapter assy 12 7mm 9 52mm 1 For use when connecting 12 type only 2 6 Limitation of refrigerant piping length CAUTION The total maximum pipe lengths and height difference of this product are shown in the table If the units are further apart than this correct operation cannot be guaranteed Pipe length Maxi...

Page 4: ...imals may live It may cause failure smoke or fire if small ani mals enter and touch internal electrical parts Area where animals may urinate on the unit or ammonia may be generated 1 If possible do not install the unit where it will be exposed to direct sunlight If necessary Install a blind that does not interfere with the air flow 2 Do not install the unit where a strong wind blows or where it is...

Page 5: ...nnect them securely and fasten them so that there is 3 no stress placed on the terminals Use an appropriate screwdriver to tighten the terminal screws Do not use a 4 screwdriver that is too small otherwise the screw heads may be damaged and prevent the screws from being properly tightened Do not tighten the terminal screws too much otherwise the screws may break 5 See the table below for the termi...

Page 6: ...efrigerant must not be discharged into atmosphere After connecting the piping check the joints for gas leakage with gas leak detector Gas leak checks are performed using either vacuum or nitrogen gas so select the proper one depending on the situation Checking gas leaks with vacuum 1 Check if the piping connections are secure 2 Remove the cap of 3 way valve and connect the gauge manifold charge ho...

Page 7: ...he air purging of the charge hose by connecting the charging hose of gauge mani fold to the charging port of 3 way valve and opening the low pressure valve slightly 2 Close the valve stem of 2 way valve completely 3 Start the cooling operation or following forced cooling operation Keep on pressing the MANUAL AUTO button of the indoor unit for more than 10 seconds The operation in dicator lamp and ...

Reviews: