INSTALLATION MANUAL

For authorized service personnel only.

INSTALLATIONSANLEITUNG

Nur für autorisiertes Personal.

MANUEL D'INSTALLATION

Pour le personnel agréé uniquement.

MANUAL DE INSTALACIÓN

Solo para personal autorizado.

MANUALE D'INSTALLAZIONE

Ad uso esclusivo del personale autorizzato.

ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ

Για εξουσιοδοτημένο προσωπικό σέρβις.

MANUAL DE INSTALAÇÃO

Apenas para técnicos autorizados.

РУКОВОДСТВО ПО УСТАНОВКЕ

Для уполномоченного персонала.

KURULUM KILAVUZU

Yetkili servis personeli içindir.

INSTALLATION MANUAL

AIR CONDITIONER
OUTDOOR UNIT

PART NO. 9377863133

9377863133_IM.indb   1

9377863133_IM.indb   1

11/25/2011   11:30:26 AM

11/25/2011   11:30:26 AM

Summary of Contents for AOYG12-14LBLA

Page 1: ... INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION...

Page 2: ... in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not place any other electrical products or household belongings under indoor unit or outdoor unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Be careful not to scratch the air conditioner when handling it After installation explain correct...

Page 3: ...Application Installation Manual 1 This manual Drain pipe 1 For outdoor unit drain piping work Adapter assy 12 7mm 9 52mm 1 For use when connecting 12 type only 2 6 Limitation of refrigerant piping length CAUTION The total maximum pipe lengths and height difference of this product are shown in the table If the units are further apart than this correct operation cannot be guaranteed Pipe length Maxi...

Page 4: ...imals may live It may cause failure smoke or fire if small ani mals enter and touch internal electrical parts Area where animals may urinate on the unit or ammonia may be generated 1 If possible do not install the unit where it will be exposed to direct sunlight If necessary Install a blind that does not interfere with the air flow 2 Do not install the unit where a strong wind blows or where it is...

Page 5: ...nnect them securely and fasten them so that there is 3 no stress placed on the terminals Use an appropriate screwdriver to tighten the terminal screws Do not use a 4 screwdriver that is too small otherwise the screw heads may be damaged and prevent the screws from being properly tightened Do not tighten the terminal screws too much otherwise the screws may break 5 See the table below for the termi...

Page 6: ...efrigerant must not be discharged into atmosphere After connecting the piping check the joints for gas leakage with gas leak detector Gas leak checks are performed using either vacuum or nitrogen gas so select the proper one depending on the situation Checking gas leaks with vacuum 1 Check if the piping connections are secure 2 Remove the cap of 3 way valve and connect the gauge manifold charge ho...

Page 7: ...he air purging of the charge hose by connecting the charging hose of gauge mani fold to the charging port of 3 way valve and opening the low pressure valve slightly 2 Close the valve stem of 2 way valve completely 3 Start the cooling operation or following forced cooling operation Keep on pressing the MANUAL AUTO button of the indoor unit for more than 10 seconds The operation in dicator lamp and ...